This Acti9 C120H is a low voltage multistandard miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 100A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 15kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 15kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. The presence of green strip guarantees that contacts open physically and allows work to be carried out safely on the downstream circuit. Its fast closing mechanism improves its service life. Acti9 C120 offer is dedicated to industrial and tertiary buildings. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is going from 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 3 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 27mm x (H) 81mm x (D) 73mm. The weight is 0.205kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -30°C to 60°C. The storage temperature is -40°C to 70°C.
Acti 9 C120
A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Availability:
In stock
1,986 EGP 3,031 EGP
In stock
CompareRange of product | C120 |
---|---|
Range | Acti9 |
Product name | C120 |
Product or component type | Miniature circuit-breaker |
Device short name | C120H |
Device application | Distribution |
Poles description | 1P |
Number of protected poles | 1 |
[In] rated current | 100 A at 30 °C |
Network type | AC |
Trip unit technology | Thermal-magnetic |
Curve code | C |
Breaking capacity | 30 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12 V DC conforming to EN/IEC 60947-2 20 kA Icu at 125 V DC conforming to EN/IEC 60947-2 15 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2 15 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15000 A Icn at 230…400 V AC 50/60 Hz conforming to EN/IEC 60898-1 4.5 kA Icu at 380…415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2 30 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
Suitability for isolation | Yes conforming to IEC 60947-2 |
Network frequency | 50/60 Hz |
---|---|
[Ue] rated operational voltage | 380…415 V AC 50/60 Hz 125 V DC <= 144 V DC 12 V DC 220…240 V AC 50/60 Hz 230…400 V AC 50/60 Hz 130 V AC 50/60 Hz 12 V AC 50/60 Hz |
Magnetic tripping limit | 5…10 x In |
[Ics] rated service breaking capacity | 15 kA 50 % conforming to EN/IEC 60947-2 – 130 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz 2.25 kA 50 % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz 7500 A 50 % conforming to EN/IEC 60898-1 – 230…400 V AC 50/60 Hz 20 kA 100 % conforming to EN/IEC 60947-2 – 12 V DC 15 kA 100 % conforming to EN/IEC 60947-2 – <= 144 V DC 20 kA 100 % conforming to EN/IEC 60947-2 – 125 V DC 15 kA 50 % conforming to EN/IEC 60947-2 – 12 V AC 50/60 Hz |
Limitation class | 3 conforming to EN/IEC 60947-2 |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 |
Contact position indicator | Yes |
control type | Toggle |
local signalling | ON/OFF indication |
Mounting mode | Clip-on |
mounting support | 35 mm symmetrical DIN rail |
Comb busbar and distribution block compatibility | NO |
9 mm pitches | 3 |
height | 81 mm |
Width | 27 mm |
Depth | 73 mm |
Net weight | 0.205 kg |
Colour | White |
Mechanical durability | 20000 cycles |
Electrical durability | 5000 cycles conforming to IEC 60947-2 |
Locking options description | Handle sealable with cable diameter 0.7mm in OFF or ON position |
Connections – terminals | Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible |
Wire stripping length | 15 mm |
Tightening torque | 3.5 N.m |
earth-leakage protection | Without |
Standards | EN/IEC 60898-1 EN/IEC 60947-2 |
---|---|
product certifications | EAC |
IP degree of protection | IP20 conforming to IEC 60529 |
Pollution degree | 3 conforming to IEC 60947-2 |
Overvoltage category | IV |
Tropicalisation | 2 conforming to IEC 60068-1 |
Relative humidity | 95 % at 55 °C |
Operating altitude | 2000 m |
ambient air temperature for operation | -30…60 °C |
Ambient air temperature for storage | -40…70 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 2.500 cm |
Package 1 Width | 7.500 cm |
Package 1 Length | 8.500 cm |
Package 1 Weight | 193.400 g |
Unit Type of Package 2 | BB1 |
Number of Units in Package 2 | 12 |
Package 2 Height | 8.500 cm |
Package 2 Width | 9.000 cm |
Package 2 Length | 33.000 cm |
Package 2 Weight | 2.378 kg |
Unit Type of Package 3 | S03 |
Number of Units in Package 3 | 72 |
Package 3 Height | 30.000 cm |
Package 3 Width | 30.000 cm |
Package 3 Length | 40.000 cm |
Package 3 Weight | 14.685 kg |
Warranty | 18 months |
---|