Fluke 376 FC True-RMS Clamp Meter with iFlex

Fluke

  • Measures AC/DC current with included iFlex current probe
  • VFD low pass filter for accurate measurements of non-linear signals
  • Remotely log, trend and monitor to pinpoint intermittent faults
  • Inrush measurement to filter out noise and capture starting current

41,500.00 EGP

Fluke 376 FC True-RMS Clamp Meter with iFlex

Product overview: Fluke 376 FC True-RMS Clamp Meter with iFlex

The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.

Find the cause of difficult problems

The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.

Measure:

  • Voltage to 1000 V AC or DC
  • Resistance to 60 kΩ with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV DC measurement range to interface with other accessories
  • 1000 μF capacitance measurement

Work safely and conveniently

The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.

The included iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:

  • Expands the measurement range to 2500 A AC
  • Allows frequency measurement to 500 Hz with body jaw and iFlex
SKU: Fluke 376 FC Category: Brand:
brands

AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
i2500-10 Flex i2500-18 Flex
A
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)
Error ±0.5 % ±0.5 %
B
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)
Error ±1.0 % ±1.0 %
C
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)
Error ±2.0 % ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Frequency via Jaw
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy 1% ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity –
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude 2000 m
Storage altitude 12,000 m
Size (L x W x H) 249 x 85 x 45 mm
Weight 395 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
i2500-10 Flex i2500-18 Flex
A
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)
Error ±0.5 % ±0.5 %
B
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)
Error ±1.0 % ±1.0 %
C
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)
Error ±2.0 % ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Frequency via Jaw
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy 1% ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity - non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude 2000 m
Storage altitude 12,000 m
Size (L x W x H) 249 x 85 x 45 mm
Weight 395 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length (head to electronics connector) 1.8 m

Datasheet

Datasheet

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Fluke 376 FC True-RMS Clamp Meter with iFlex”

There are no reviews yet.

SHOPPING CART