-35%
, , ,

Schneider 25439 | C60 – circuit breaker – C60L – 3P – 25A – C curve


Schneider 25439 | C60 – circuit breaker – C60L – 3P – 25A – C curve

2,632 EGP 4,018 EGP

Compare

Schneider 25439 | C60 – circuit breaker – C60L – 3P – 25A – C curve 

1. Technical Specifications

  • Model: 25439 C60L
  • Type: Miniature Circuit Breaker (MCB)
  • Number of Poles: 3P (Three Poles)
  • Rated Current: 25A
  • Tripping Curve: C Curve (Trips at 5 to 10 times the rated current)
  • Operating Voltage: 400V AC
  • Breaking Capacity: 10kA
  • Tripping Mechanism: Thermal-Magnetic
  • Frequency: 50/60Hz
  • Protection Rating: IP20 (Suitable for panel installation)
  • Mounting: DIN Rail (35mm standard rail)

2. Key Features

A. Reliable Overload and Short Circuit Protection

  • Uses a thermal-magnetic mechanism that responds to both overcurrent conditions and short circuits, ensuring fast and efficient circuit protection.

B. C Curve Tripping Characteristic

  • Designed to handle moderate inrush currents from lighting circuits, small motors, and resistive loads. It trips when current exceeds 5 to 10 times the rated value, reducing the risk of nuisance tripping.

C. High Breaking Capacity (10kA)

  • Can safely interrupt high fault currents, preventing damage to electrical systems and ensuring system reliability.

D. Compact and Easy to Install

  • Designed for quick and secure mounting on a DIN rail, allowing for efficient installation and maintenance.

E. Compliance with International Standards

  • Meets IEC 60898-1 and IEC 60947-2 standards, ensuring compatibility with a wide range of electrical applications.

3. Applications and Uses

The Schneider 25439 C60L is widely used in various applications, including:

A. Industrial and Commercial Electrical Protection

  • Provides reliable circuit protection in factories, warehouses, and office buildings.

B. Control and Distribution Panels

  • Essential for protecting main distribution panels and electrical control boards.

C. General Electrical Loads

  • Ideal for protecting circuits that supply lighting, outlets, and other electrical devices.

D. Renewable Energy Systems

  • Can be integrated into solar and wind power systems for added circuit safety.
Main
Range of productC60
RangeMulti9
product nameC60
Product or component typeMiniature circuit-breaker
Device short nameC60L
Device applicationDistribution
Poles description3P
Number of protected poles3
[In] rated current25 A at 40 °C
network typeDC
AC
Trip unit technologyThermal-magnetic
Curve codeC
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 230…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 400…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
30 kA Icu at 125 V DC 2P conforming to EN/IEC 60947-2
50 kA Icu at 125 V DC 3P conforming to EN/IEC 60947-2
60 kA Icu at <= 250 V DC 4P conforming to EN/IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-2
Complementary
Network frequency50/60 Hz
[Ue] rated operational voltage440 V AC 50/60 Hz
230…240 V AC 50/60 Hz
400…415 V AC 50/60 Hz
<= 250 V DC
Magnetic tripping limit7…10 x In
[Ics] rated service breaking capacity10 kA conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
25 kA conforming to EN/IEC 60947-2 – 230…240 V AC 50/60 Hz
12.5 kA conforming to EN/IEC 60947-2 – 400…415 V AC 50/60 Hz
Limitation class3 conforming to EN/IEC 60947-2
Contact position indicatorYes
Control typeToggle
Local signallingON/OFF indication
Mounting modeClip-on
Mounting support35 mm symmetrical DIN rail
Comb busbar and distribution block compatibilityNO
9 mm pitches6
Height81 mm
Width54 mm
Depth73 mm
Product weight0.36 kg
Mechanical durability20000 cycles
Connections – terminalsTunnel type terminals16 mm² flexible
Tunnel type terminals25 mm² rigid
Tightening torquePower circuit: 2 N.m upside
2 N.m downside
Earth-leakage protectionSeparate block
Product compatibilityC60 accessories
C60 auxiliary
Environment
StandardsEN/IEC 60947-2
EN 60898
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Operating altitude2000 m
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-40…70 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.5 cm
Package 1 Width5.4 cm
Package 1 Length7.3 cm
Package 1 Weight0.333 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider 25439 | C60 – circuit breaker – C60L – 3P – 25A – C curve”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!