Let's Chat
-36%

Schneider 56130 | Earth-leakage relay RH10M – 30 mA – 240 V

Schneider Electric
Availability:

In stock


Schneider 56130

22,070 EGP 34,485 EGP

In stock

Compare

Schneider 56130

Schneider 56130: Comprehensive Guide

The Schneider 56130 stands as an essential component in contemporary electrical systems, renowned for its reliability and efficiency. This guide aims to delve into it, elucidating its features, applications, installation process, benefits, and more.

About Schneider Electric

With a rich history tracing back to it, Schneider Electric has solidified its position as a global leader in energy management and automation solutions. Renowned for innovation and sustainability, Schneider Electric continues to shape the landscape of the electrical industry.

Detailed Overview of Schneider 56130

it epitomizes versatility and reliability, boasting the following key features and specifications:

  • Robust Construction: Engineered to withstand demanding conditions, ensuring longevity and durability.
  • Advanced Functionality: Equipped with innovative features for efficient energy management and enhanced performance.
  • User-friendly Design: Simple installation, operation, and maintenance cater to professionals and enthusiasts alike.

Applications of Schneider 56130

Industrial Utilization: it finds widespread application in industrial settings, facilitating power distribution, motor control, and automation, thereby enhancing operational efficiency and productivity.

Commercial Applications: In commercial establishments, it optimizes energy consumption, reduces operational costs, and ensures uninterrupted power supply, contributing to sustainability and cost-effectiveness.

Residential Implementations: Homeowners benefit from it’s reliability, ensuring a stable electrical supply for household needs while promoting energy savings and safety.

Installation Process

Installing it follows these steps:

  1. Preparation: Gather necessary tools and equipment.
  2. Safety First: Adhere to safety guidelines for accident prevention.
  3. Mounting: Secure the unit in the designated location.
  4. Wiring: Connect wires according to provided instructions.
  5. Testing: Conduct comprehensive tests to ensure functionality.

Advantages of Using Schneider 56130

  • Enhanced Efficiency: Optimizes energy usage, leading to cost savings and reduced environmental impact.
  • Cost-effectiveness: Offers superior performance at competitive prices.
  • User-friendly Design: Simplifies installation, operation, and maintenance, saving time and effort.

Comparative Analysis of Schneider 56130 with Other Products

Schneider 56130 excels due to:

  • Distinct Features: Innovative functionalities set it apart from competitors.
  • Advantages: Offers superior performance, reliability, and ease of use compared to similar products.

Troubleshooting and Maintenance

Regular inspections and timely maintenance ensure optimal performance and longevity. Identifying common issues and adhering to maintenance protocols are essential for prolonged lifespan.

Customer Feedback and Testimonials

Users praise it for its reliability, efficiency, and user-friendly design. Real-world experiences underscore its efficacy in diverse applications.

Procurement of Schneider 56130

it is available through authorized distributors, retailers, and online platforms, ensuring accessibility and authenticity.

Pricing and Warranty Details

Pricing varies based on factors such as configuration and quantity. Warranty coverage provides peace of mind to customers, ensuring support and assistance in case of issues.

Future Prospects of Schneider 56130

Continuous innovation and development signify promising prospects for it. Schneider Electric’s commitment to advancement ensures its relevance in evolving electrical systems.

Expert Opinions on Schneider 56130

Industry experts recognize it’s efficacy and anticipate its continued prominence in energy management and automation solutions.

Environmental Impact

it incorporates sustainability features, aligning with Schneider Electric’s environmental initiatives, and reducing carbon footprints.

Conclusion

In summary, it emerges as a pivotal component in electrical systems, offering reliability, efficiency, and user-friendliness across industrial, commercial, and residential domains.

SKU: 56130 Category:
Main
Range VigiPacT
Device short name RH10M
Product or component type Residual current protection relay
Relay application Protection relay
mounting support DIN rail
Earth-leakage protection class Type A
Type of setting None
Residual earth-leakage sensitity adjustment type Fixed
Earth-leakage sensitivity 0.03 A
Earth-leakage time delay Instantaneous
Current sensors compatibility VigiPacT TOA earth leakage current sensor
VigiPacT A earth leakage current sensor
VigiPacT L earth leakage current sensor
[Ithe] conventional enclosed thermal current 8 A
Minimum load 10 mA at 12 V
[Us] rated supply voltage 220…240 V AC 50/60 Hz 55…110 %
Power consumption in VA 4 VA
Monitored distribution system 1000 V – AC at 50/60 Hz (maximum)
1000 V – AC at 400 Hz (maximum)
Earthing system TN-S
IT
TT
[Uimp] rated impulse withstand voltage 8 kV
Reset Manual reset
Complementary
Test function Local
Remote test
Monitoring Electronics (continuous)
Power supply (continuous)
Relay/sensor link (continuous)
Type of measurement Earth fault current internal measurement, range: 80…100 %
Tamperproof of settings Protected by sealable cover
Connections – terminals Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24…AWG 12
Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24…AWG 12
Fault: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Fault: screw terminal cable(s) 0.2…4 mm² rigid AWG 24…AWG 12
Fault: screw terminal cable(s) 0.25…2.5 mm² flexible AWG 24…AWG 12
Relay test and fault reset: screw terminal cable(s) 0.14…1 mm² flexible AWG 26…AWG 16
Relay test and fault reset: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26…AWG 16
Relay test and fault reset: screw terminal cable(s) 0.25…0.5 mm² flexible AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.14…1 mm² flexible AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.25…0.5 mm² flexible AWG 26…AWG 16
Voltage presence: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Voltage presence: screw terminal cable(s) 0.2…4 mm² rigid AWG 24…AWG 12
Voltage presence: screw terminal cable(s) 0.25…2.5 mm² flexible AWG 24…AWG 12
Wire stripping length Auxiliary power supply: 7 mm for top connection
Fault: 8 mm for bottom connection
Relay test and fault reset: 5 mm for bottom connection
Sensor: 5 mm for top connection
Voltage presence: 8 mm for bottom connection
Tightening torque Auxiliary power supply: 0.6 N.m top
Fault: 0.6 N.m bottom
Relay test and fault reset: 0.25 N.m bottom
Sensor: 0.25 N.m top
Voltage presence: 0.6 N.m bottom
9 mm pitches 6
Standards EN/IEC 60947-2 Annex M
EN/IEC 60755
UL 1053
CAN/CSA C22.2 No. 144
Width 54 mm
height 81 mm
Depth 74 mm
Net weight 0.3 kg
IP degree of protection IP40 on front face: conforming to EN/IEC 60529
IP30 on side parts: conforming to EN/IEC 60529
IP20 on connection terminals: conforming to EN/IEC 60529
IK degree of protection IK07 conforming to EN 50102
Mechanical robustness Fire resistance conforming to IEC 60695-2-1
IK protection 2 joules: IK07 conforming to EN 50102
Vibrations 13.2…100 Hz: 0.7 g
Vibrations 2…13.2 Hz: +/- 1 mm
Environment
Overvoltage category IV
Electrical shock protection class Class II
Electromagnetic compatibility Conducted and radiated emissions: , B, conforming to CISPR 11
Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6
Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2
High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5
Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4
Radiated susceptibility: , 3, conforming to IEC 61000-4-3
Relative humidity 95 % at 55 °C
Pollution degree 3 conforming to IEC 60664-1
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -55…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.0 cm
Package 1 Width 8.6 cm
Package 1 Length 9.0 cm
Package 1 Weight 274.0 g
Unit Type of Package 2 S03
Number of Units in Package 2 36
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 10.351 kg
Contractual warranty
Warranty 12 months

Main Document

Data Sheet : Download56130

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider 56130 | Earth-leakage relay RH10M – 30 mA – 240 V”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024