-34%

Schneider 56130 | Earth-leakage relay RH10M – 30 mA – 240 V

Schneider Electric
Availability:

In stock


Schneider 56130

22,760 EGP 34,485 EGP

In stock

Compare

Schneider 56130

Schneider 56130: Comprehensive Guide

The Schneider 56130 stands as an essential component in contemporary electrical systems, renowned for its reliability and efficiency. This guide aims to delve into it, elucidating its features, applications, installation process, benefits, and more.

About Schneider Electric

With a rich history tracing back to it, Schneider Electric has solidified its position as a global leader in energy management and automation solutions. Renowned for innovation and sustainability, Schneider Electric continues to shape the landscape of the electrical industry.

Detailed Overview of Schneider 56130

it epitomizes versatility and reliability, boasting the following key features and specifications:

  • Robust Construction: Engineered to withstand demanding conditions, ensuring longevity and durability.
  • Advanced Functionality: Equipped with innovative features for efficient energy management and enhanced performance.
  • User-friendly Design: Simple installation, operation, and maintenance cater to professionals and enthusiasts alike.

Applications of Schneider 56130

Industrial Utilization: it finds widespread application in industrial settings, facilitating power distribution, motor control, and automation, thereby enhancing operational efficiency and productivity.

Commercial Applications: In commercial establishments, it optimizes energy consumption, reduces operational costs, and ensures uninterrupted power supply, contributing to sustainability and cost-effectiveness.

Residential Implementations: Homeowners benefit from it’s reliability, ensuring a stable electrical supply for household needs while promoting energy savings and safety.

Installation Process

Installing it follows these steps:

  1. Preparation: Gather necessary tools and equipment.
  2. Safety First: Adhere to safety guidelines for accident prevention.
  3. Mounting: Secure the unit in the designated location.
  4. Wiring: Connect wires according to provided instructions.
  5. Testing: Conduct comprehensive tests to ensure functionality.

Advantages of Using Schneider 56130

  • Enhanced Efficiency: Optimizes energy usage, leading to cost savings and reduced environmental impact.
  • Cost-effectiveness: Offers superior performance at competitive prices.
  • User-friendly Design: Simplifies installation, operation, and maintenance, saving time and effort.

Comparative Analysis of Schneider 56130 with Other Products

Schneider 56130 excels due to:

  • Distinct Features: Innovative functionalities set it apart from competitors.
  • Advantages: Offers superior performance, reliability, and ease of use compared to similar products.

Troubleshooting and Maintenance

Regular inspections and timely maintenance ensure optimal performance and longevity. Identifying common issues and adhering to maintenance protocols are essential for prolonged lifespan.

Customer Feedback and Testimonials

Users praise it for its reliability, efficiency, and user-friendly design. Real-world experiences underscore its efficacy in diverse applications.

Procurement of Schneider 56130

it is available through authorized distributors, retailers, and online platforms, ensuring accessibility and authenticity.

Pricing and Warranty Details

Pricing varies based on factors such as configuration and quantity. Warranty coverage provides peace of mind to customers, ensuring support and assistance in case of issues.

Future Prospects of Schneider 56130

Continuous innovation and development signify promising prospects for it. Schneider Electric’s commitment to advancement ensures its relevance in evolving electrical systems.

Expert Opinions on Schneider 56130

Industry experts recognize it’s efficacy and anticipate its continued prominence in energy management and automation solutions.

Environmental Impact

it incorporates sustainability features, aligning with Schneider Electric’s environmental initiatives, and reducing carbon footprints.

Conclusion

In summary, it emerges as a pivotal component in electrical systems, offering reliability, efficiency, and user-friendliness across industrial, commercial, and residential domains.

SKU: 56130 Category: Brand:
Main
RangeVigiPacT
Device short nameRH10M
Product or component typeResidual current protection relay
Relay applicationProtection relay
mounting supportDIN rail
Earth-leakage protection classType A
Type of settingNone
Residual earth-leakage sensitity adjustment typeFixed
Earth-leakage sensitivity0.03 A
Earth-leakage time delayInstantaneous
Current sensors compatibilityVigiPacT TOA earth leakage current sensor
VigiPacT A earth leakage current sensor
VigiPacT L earth leakage current sensor
[Ithe] conventional enclosed thermal current8 A
Minimum load10 mA at 12 V
[Us] rated supply voltage220…240 V AC 50/60 Hz 55…110 %
Power consumption in VA4 VA
Monitored distribution system1000 V – AC at 50/60 Hz (maximum)
1000 V – AC at 400 Hz (maximum)
Earthing systemTN-S
IT
TT
[Uimp] rated impulse withstand voltage8 kV
ResetManual reset
Complementary
Test functionLocal
Remote test
MonitoringElectronics (continuous)
Power supply (continuous)
Relay/sensor link (continuous)
Type of measurementEarth fault current internal measurement, range: 80…100 %
Tamperproof of settingsProtected by sealable cover
Connections – terminalsAuxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24…AWG 12
Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24…AWG 12
Fault: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Fault: screw terminal cable(s) 0.2…4 mm² rigid AWG 24…AWG 12
Fault: screw terminal cable(s) 0.25…2.5 mm² flexible AWG 24…AWG 12
Relay test and fault reset: screw terminal cable(s) 0.14…1 mm² flexible AWG 26…AWG 16
Relay test and fault reset: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26…AWG 16
Relay test and fault reset: screw terminal cable(s) 0.25…0.5 mm² flexible AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.14…1 mm² flexible AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.25…0.5 mm² flexible AWG 26…AWG 16
Voltage presence: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Voltage presence: screw terminal cable(s) 0.2…4 mm² rigid AWG 24…AWG 12
Voltage presence: screw terminal cable(s) 0.25…2.5 mm² flexible AWG 24…AWG 12
Wire stripping lengthAuxiliary power supply: 7 mm for top connection
Fault: 8 mm for bottom connection
Relay test and fault reset: 5 mm for bottom connection
Sensor: 5 mm for top connection
Voltage presence: 8 mm for bottom connection
Tightening torqueAuxiliary power supply: 0.6 N.m top
Fault: 0.6 N.m bottom
Relay test and fault reset: 0.25 N.m bottom
Sensor: 0.25 N.m top
Voltage presence: 0.6 N.m bottom
9 mm pitches6
StandardsEN/IEC 60947-2 Annex M
EN/IEC 60755
UL 1053
CAN/CSA C22.2 No. 144
Width54 mm
height81 mm
Depth74 mm
Net weight0.3 kg
IP degree of protectionIP40 on front face: conforming to EN/IEC 60529
IP30 on side parts: conforming to EN/IEC 60529
IP20 on connection terminals: conforming to EN/IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Mechanical robustnessFire resistance conforming to IEC 60695-2-1
IK protection 2 joules: IK07 conforming to EN 50102
Vibrations 13.2…100 Hz: 0.7 g
Vibrations 2…13.2 Hz: +/- 1 mm
Environment
Overvoltage categoryIV
Electrical shock protection classClass II
Electromagnetic compatibilityConducted and radiated emissions: , B, conforming to CISPR 11
Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6
Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2
High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5
Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4
Radiated susceptibility: , 3, conforming to IEC 61000-4-3
Relative humidity95 % at 55 °C
Pollution degree3 conforming to IEC 60664-1
ambient air temperature for operation-35…70 °C
Ambient air temperature for storage-55…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.0 cm
Package 1 Width8.6 cm
Package 1 Length9.0 cm
Package 1 Weight274.0 g
Unit Type of Package 2S03
Number of Units in Package 236
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight10.351 kg
Contractual warranty
Warranty12 months

Main Document

Data Sheet : Download56130

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider 56130 | Earth-leakage relay RH10M – 30 mA – 240 V”

There are no reviews yet.

SHOPPING CART