Schneider A9D11810 | Acti9 iC60  with overcurrent protection (RCBO).  1P+N circuit breaker with 1 protected pole, 10A

Product Overview: Schneider A9D11810 | iC60H RCBO – 1P+N – 10A – C Curve – 30mA – 240V

The Schneider Electric A9D11810 is a high-performance earth leakage circuit breaker from the Acti9 iC60H range. It features 1P+N (single pole + neutral) configuration, a C curve tripping characteristic, a rated current of 10A, and a residual current sensitivity of 30 mA. Designed for 240V AC applications, this RCBO provides both overcurrent protection and earth leakage protection, making it ideal for residential and commercial electrical safety.

Key Features:

  • Brand: Schneider Electric

  • Series: Acti9 iC60H

  • Model Number: A9D11810

  • Product Type: RCBO (Residual Current Breaker with Overcurrent)

  • Poles: 1P + N (Single Pole + Neutral)

  • Tripping Curve: C Curve

  • Rated Current: 10A

  • Residual Current Sensitivity: 30 mA

  • Rated Voltage: 240V AC

Technical Specifications:

  • Breaking Capacity: High-performance short-circuit protection

  • Sensitivity: 30 mA (for personal protection against electric shocks)

  • Tripping Curve: Type C (ideal for general-purpose loads with moderate inrush current)

  • Frequency: 50/60 Hz

  • Mounting: DIN rail

  • Standards Compliance: IEC 61009-1

Functional Features:

  • Dual Protection:
    – Provides protection against earth leakage and overcurrent (short circuit and overload)

  • Compact Design:
    – Saves space in distribution boards

  • Visual Indicators:
    – Clear ON/OFF and fault indication

  • High Reliability:
    – Long electrical and mechanical lifespan

  • Resettable:
    – Can be manually reset after a fault occurs

Applications:

  • Residential homes

  • Commercial buildings

  • Small office environments

  • Protection of socket outlets, lighting, and appliances

  • Areas with risk of direct contact or moisture

Benefits:

  • Enhanced Safety:
    – Detects even small leakage currents (30 mA) to protect human life

  • Quick Response:
    – Rapid disconnection in the event of a fault

  • Ease of Use:
    – Simple installation and reset mechanism

  • Space Efficiency:
    – 1 module width per pole

  • Compliance & Trust:
    – Backed by Schneider’s global quality standards

Typical Users:

  • Electricians and installers

  • Residential developers

  • Electrical maintenance teams

  • Building contractors

  • Facility managers

SKU: A9D11810 Category: Brand:
Main
circuit breaker application Distribution
Range Acti9
Product name Acti9 iC60 RCBO
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60H RCBO
Poles description 1P + Ns
[In] rated current 10 A at 50 °C
Earthing system TN
Curve code C
Earth-leakage sensitivity 30 mA
Breaking capacity 10000 A Icn at 230/240 V AC 50/60 Hz
Complementary
Neutral position Left
Number of protected poles 1
device location in system Outgoer
Network frequency 50 Hz
Network type AC
Trip unit technology Thermal-magnetic
[Ue] rated operational voltage 230/240 V AC 50/60 Hz
Residual current tripping technology Voltage dependent
earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A
[Icw] rated short-time withstand current Icw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacity 7500 A at 230/240 V AC 50/60 Hz
Limitation class 3
[Ui] rated insulation voltage 400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Suitability for isolation Yes
Contact position indicator Yes
control type Toggle
local signalling ON/OFF indication
Mounting mode Clip-on
mounting support DIN rail
Comb busbar and distribution block compatibility NO
9 mm pitches 2
height 110 mm
Width 18 mm
Depth 77.5 mm
Net weight 205 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 5000 cycles
Provision for padlocking Padlockable with padlock Ø 4 mm
Locking options description ON/OFF locking facilities
Connections – terminals Screw clamp terminal (top) 1…25 mm² rigid without cable end
Screw clamp terminal (top) 1…16 mm² flexible
Screw clamp terminal (bottom) 1…16 mm² rigid without cable end
Screw clamp terminal (bottom) 1…10 mm² flexible
Wire stripping length Power circuit: 13 mm for bottom connection
Power circuit: 14 mm for top connection
Tightening torque Power circuit: 3.5 N.m top
Power circuit: 2 N.m bottom
earth-leakage protection Integrated
Environment
Standards BS EN 61009-1
IEC 61009-1
IEC 61009-2-2
AS/NZS 61009.1
IP degree of protection IP20
Tropicalisation 2
Relative humidity 95 % at 55 °C
ambient air temperature for operation -15…60 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.5 cm
Package 1 Width 11.2 cm
Package 1 Length 13.8 cm
Package 1 Weight 216 g
Unit Type of Package 2 S02
Number of Units in Package 2 34
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 7.662 kg
Unit Type of Package 3 P12
Number of Units in Package 3 1088
Package 3 Height 77 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 261.568 kg

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9D11810 | iC60H – earth leakage circuit breaker – 1P + N – C curve – 10 A – 30 mA – 240 V”

There are no reviews yet.

SHOPPING CART

close
Let's Chat