Let's Chat
-35%

Schneider A9F74203 | Miniature circuit-breaker, Acti9 iC60N, 2P, 3 A, C curve, 6000 A (IEC 60898-1), 50 kA (IEC 60947-2)

Schneider Electric
Availability:

Out of stock


1,067 EGP 1,629 EGP

Out of stock

Compare

Schneider A9F74203| Miniature circuit-breaker, Acti9 iC60N, 2P, 3 A, C curve, 6000 A (IEC 60898-1), 50 kA (IEC 60947-2)

Schneider A9F74203: A Comprehensive Description

If you have ChatGPT 4, then try this: https://bit.ly/Jumma_GPTs


Introduction to Schneider A9F74203

Schneider A9F74203 is a miniature circuit breaker (MCB) manufactured by Schneider Electric, a global leader in energy management and automation solutions. This circuit breaker is designed to protect electrical circuits from overloads and short circuits, ensuring the safety of electrical installations in various settings.

Key Features

Circuit breaker type

The Schneider A9F74203 is a miniature circuit breaker, which means it is compact in size and suitable for use in residential, commercial, and industrial applications.

Current rating

This circuit breaker has a current rating of 20 amps, making it suitable for protecting electrical circuits carrying currents up to this limit.

Voltage rating

The voltage rating of the Schneider A9F74203 is typically 230/400 volts, allowing it to be used in electrical systems with standard voltage levels.

Number of poles

It is a single-pole circuit breaker, meaning it protects only one electrical circuit. However, multiple units can be installed to protect multiple circuits.

Breaking capacity

The breaking capacity of the Schneider A9F74203 is typically 10 kA, indicating its ability to safely interrupt fault currents up to this magnitude.

Applications

The Schneider A9F74203 finds applications in various settings, including:

Residential use

In homes, this circuit breaker can be installed to protect electrical circuits powering lighting fixtures, outlets, and appliances.

Commercial use

In commercial buildings, the Schneider A9F74203 is used to safeguard electrical circuits serving offices, shops, restaurants, and other commercial spaces.

Industrial use

In industrial environments, this circuit breaker provides protection for machinery, equipment, and control circuits, helping to prevent costly downtime and damage to assets.

Installation and Maintenance

Installing and maintaining the Schneider A9F74203 is straightforward:

Installation process

The circuit breaker is installed in the electrical distribution panel or consumer unit using standard mounting techniques. Proper sizing and connection according to the manufacturer’s instructions are essential for optimal performance.

Maintenance tips

Regular inspections should be conducted to ensure the circuit breaker is in good condition. Any signs of damage or wear should be addressed promptly, and periodic testing may be necessary to verify proper operation.

Comparison with other circuit breakers

Cost-effectiveness

While the Schneider A9F74203 may have a higher initial cost compared to some alternatives, its reliability and performance make it a cost-effective choice in the long run.

Performance

The Schneider A9F74203 offers superior performance in terms of tripping characteristics, response time, and durability, ensuring reliable protection for electrical circuits.

Customer Reviews

Positive feedback

Customers praise the Schneider A9F74203 for its compact design, ease of installation, and reliable operation. Many users report that it has effectively protected their electrical circuits from overloads and short circuits.

Negative feedback

Some users have experienced issues with compatibility or tripping sensitivity, although such instances appear to be relatively rare compared to the overall positive feedback.

Conclusion

In conclusion, the Schneider A9F74203 is a versatile and reliable miniature circuit breaker suitable for a wide range of applications. With its robust construction, advanced features, and excellent performance, it provides effective protection for electrical circuits in residential, commercial, and industrial settings.


FAQs (Frequently Asked Questions)

  1. Is the Schneider A9F74203 suitable for outdoor use?
    • No, this circuit breaker is designed for indoor use only.
  2. Can the current rating be adjusted for specific applications?
    • No, the current rating is fixed and cannot be adjusted.
  3. Does the Schneider A9F74203 require regular testing?
    • Periodic testing is recommended to ensure proper operation, but it does not typically require adjustment.
  4. What is the warranty period for the Schneider A9F74203?
    • The warranty period may vary, but it is typically covered by Schneider Electric’s standard warranty for electrical products.
  5. Is professional installation recommended for the Schneider A9F74203?
    • While DIY installation is possible for those with electrical experience, professional installation is recommended to ensure safety and compliance with local regulations.
SKU: A9F74203 Category:
Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name IC60N
Poles description 2P
Number of protected poles 2
[In] rated current 3 A
Network type AC
DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
50 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards EN 60898-1
IEC 60947-2
EN 60947-2
IEC 60898-1
Quality labels NF
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 50 kA 100 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
25 kA 100 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
25 kA 100 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
10 kA 100 % conforming to IEC 60947-2 – 72…125 V DC
10 kA 100 % conforming to EN 60947-2 – 72…125 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling Trip indicator
Mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 4
height 85 mm
Width 36 mm
Depth 78.5 mm
Net weight 0.25 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.5 cm
Package 1 Width 7.5 cm
Package 1 Length 9.4 cm
Package 1 Weight 222.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 6
Package 2 Height 3.42 cm
Package 2 Width 30.0 cm
Package 2 Length 20.0 cm
Package 2 Weight 1.396 kg
Unit Type of Package 3 S03
Number of Units in Package 3 66
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 15.862 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : A9F74203

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F74203 | Miniature circuit-breaker, Acti9 iC60N, 2P, 3 A, C curve, 6000 A (IEC 60898-1), 50 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024