Let's Chat
-35%

Schneider A9F74303 | Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 3A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)

Schneider Electric
Availability:

In stock


1,919 EGP 2,930 EGP

In stock

Compare

Schneider A9F74303| Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 3A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)

Schneider A9F74303 Description

If you have ChatGPT 4, then try this: https://bit.ly/Jumma_GPTs

I. Introduction to Schneider A9F74303

Schneider A9F74303 is a high-quality miniature circuit breaker (MCB) designed to provide reliable protection for electrical circuits. With its advanced features and robust construction, it is widely used in both residential and commercial settings. Understanding the features and applications of Schneider A9F74303 is crucial for ensuring the safety and efficiency of electrical systems.

A. Brief Overview

Schneider A9F74303 is part of the Acti9 series of circuit breakers manufactured by Schneider Electric, a global leader in energy management and automation solutions. It is specifically designed to protect circuits against overloads and short circuits, thereby preventing electrical hazards such as fires and equipment damage.

B. Importance of Circuit Breakers

Circuit breakers play a vital role in electrical systems by interrupting the flow of current in the event of an overload or short circuit. This helps prevent damage to electrical equipment and ensures the safety of individuals working with or around the electrical installation.

II. Features of Schneider A9F74303

A. Current Rating and Breaking Capacity

Schneider A9F74303 is available with different current ratings to suit various applications, ranging from 6A to 63A. It also offers a high breaking capacity, allowing it to safely interrupt fault currents up to a certain level, typically 6kA or higher.

B. Trip Characteristics

The circuit breaker is equipped with precise trip characteristics, ensuring quick and reliable operation in response to overloads and short circuits. This helps minimize downtime and prevents damage to connected devices.

C. Compact Design and Easy Installation

One of the key advantages of Schneider A9F74303 is its compact design, which allows for easy installation even in confined spaces. The breaker is designed to fit standard DIN rail mounting, making it compatible with a wide range of electrical panels and enclosures.

III. Applications of Schneider A9F74303

A. Residential Applications

In residential settings, Schneider A9F74303 is commonly used to protect circuits supplying power to lighting, outlets, and appliances. Its compact size and reliable performance make it an ideal choice for modern homes.

B. Commercial and Industrial Applications

In commercial and industrial environments, Schneider A9F74303 is deployed to safeguard critical electrical circuits in offices, factories, and warehouses. It provides essential protection against electrical faults, helping businesses maintain productivity and safety.

IV. Benefits of Schneider A9F74303

A. Enhanced Safety

By promptly interrupting fault currents, Schneider A9F74303 helps prevent electrical hazards such as fires and electrocution. Its reliable performance ensures the safety of both people and property.

B. Protection of Electrical Equipment

The circuit breaker protects connected devices and equipment from damage caused by overloads and short circuits. This extends the lifespan of electrical installations and reduces maintenance costs.

C. Reliable Performance

Schneider A9F74303 is engineered for durability and reliability, delivering consistent performance even in demanding environments. Its advanced features and high-quality construction make it a trusted choice for electrical professionals worldwide.

V. Installation and Maintenance

A. Proper Installation Guidelines

When installing Schneider A9F74303, it is essential to follow the manufacturer’s instructions and comply with local electrical codes and regulations. This ensures safe and reliable operation of the circuit breaker.

B. Regular Maintenance Tips

To maintain optimal performance, periodic inspection and testing of Schneider A9F74303 are recommended. This includes checking for signs of wear or damage, verifying proper operation, and replacing worn components as needed.

VI. Comparison with Other Circuit Breakers

Schneider A9F74303 stands out from other circuit breakers due to its advanced features, compact design, and reliable performance. When compared to traditional fuses or older circuit breaker models, it offers superior protection and convenience.

VII. Frequently Asked Questions (FAQs)

Q1. What is the difference between an MCB and an RCCB?

Q2. Can Schneider A9F74303 be used for outdoor applications?

Q3. What is the typical lifespan of Schneider A9F74303?

Q4. Is it necessary to reset the circuit breaker after it trips?

Q5. How can I determine the correct rating for Schneider A9F74303 for my application?

In conclusion, Schneider A9F74303 is a versatile and reliable circuit breaker suitable for a wide range of residential, commercial, and industrial applications. Its advanced features, compact design, and ease of installation make it a preferred choice for electrical professionals and homeowners alike.

SKU: A9F74303 Category:
Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name IC60N
Poles description 3P
Number of protected poles 3
[In] rated current 3 A
Network type DC
AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
50 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards EN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
Quality labels NF
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 50 kA 100 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
25 kA 100 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
25 kA 100 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
10 kA 100 % conforming to IEC 60947-2 – 125…180 V DC
10 kA 100 % conforming to EN 60947-2 – 125…180 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling Trip indicator
Mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 6
height 85 mm
Width 54 mm
Depth 78.5 mm
Net weight 0.375 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.500 cm
Package 1 Width 7.500 cm
Package 1 Length 9.500 cm
Package 1 Weight 339.300 g
Unit Type of Package 2 BB1
Number of Units in Package 2 4
Package 2 Height 8.000 cm
Package 2 Width 10.000 cm
Package 2 Length 22.500 cm
Package 2 Weight 1.418 kg
Unit Type of Package 3 S03
Number of Units in Package 3 44
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 16.031 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : A9F74303

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F74303 | Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 3A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024