Let's Chat
,

Schneider A9F75116 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 16A, D curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)

Schneider Electric
Availability:

Out of stock


Compare

Schneider A9F75116 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 16A, D curve, 6000A (IEC/EN 60898-1), 10kA (IEC/EN 60947-2)

Schneider A9F75116 Description

This Acti9 iC60N is a low voltage miniature circuit breaker (MCB).
It is a 1P circuit breaker with 1 protected pole, 16A rated current and D tripping curve.
The rated short circuit breaking capacity goes up to 10kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 230VAC conforming to EN/IEC 60898-1 standard.
It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2.
This miniature circuit breaker protects circuits against short circuit and overload current.
Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit.
Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life.
It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC.
Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost.
The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm.
Pollution degree is 3. Overvoltage category is IV.
The product colour is white (RAL9003).
The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm.
The weight is 0.215kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure.
The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

The Schneider A9F75116 is a miniature circuit breaker (MCB) from the Schneider Electric Acti 9 series. Here’s a detailed description of its features and specifications:

  1. Type: 1-pole, 1-module device.
  2. Current Rating: Rated for 16 amps.
  3. Voltage: Suitable for voltages up to 240V AC.
  4. Breaking Capacity: Provides a breaking capacity of 10 kA according to IEC/EN 60898-1 standard.
  5. Trip Curve: C-curve characteristic, meaning it trips in response to overload currents between 5 to 10 times the rated current.

Applications:

  • Ideal for protecting electrical circuits in residential, commercial, and industrial installations.
  • Commonly used in distribution boards and consumer units where single-pole protection is required.

Features:

  • Compact and modular design for efficient use of space in electrical panels.
  • DIN rail mountable for easy and quick installation.
  • High reliability and durability, ensuring long-term performance.
  • Provides effective protection against overloads and short circuits, contributing to the safety and reliability of electrical systems.

The Schneider A9F75116 MCB is engineered to offer robust and efficient circuit protection, ensuring the safety and integrity of electrical installations acrossa variety of applications.

SKU: A9F75116 Categories: ,
brands

Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
product or component type Miniature circuit-breaker
Device short name IC60N
poles description 1P
Number of protected poles 1
[In] rated current 16 A
Network type DC
AC
Trip unit technology Thermal-magnetic
Curve code D
Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
10 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards IEC 60898-1
EN 60898-1
IEC 60947-2
EN 60947-2
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 12 x In +/- 20 %
[Ics] rated service breaking capacity 27 kA 75 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15 kA 75 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 – 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
10 kA 100 % conforming to EN 60947-2 – 72 V DC
10 kA 100 % conforming to IEC 60947-2 – 72 V DC
15 kA 100 % conforming to EN 60947-2 – 12…60 V DC
15 kA 100 % conforming to IEC 60947-2 – 12…60 V DC
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 2
Height 85 mm
Width 18 mm
Depth 78.5 mm
net weight 0.215 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.8 cm
Package 1 Width 7.5 cm
Package 1 Length 9.5 cm
Package 1 Weight 109.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.0 cm
Package 2 Width 9.5 cm
Package 2 Length 22.5 cm
Package 2 Weight 1.372 kg
Unit Type of Package 3 S03
Number of Units in Package 3 132
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 15.618 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall