-35%
,

Schneider A9F77220 | Miniature circuit-breaker, Acti9 iC60N, 2P, 20 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)

Schneider Electric
Availability:

In stock


Schneider A9F77220

750 EGP 1,145 EGP

In stock

Compare

Schneider A9F77220

Introduction

In today’s electrically powered world, ensuring the safety and efficiency of electrical systems is essential. One crucial component in achieving this is the circuit breaker. Among the many options available, it stands out. This guide will explore everything you need to know about this particular circuit breaker, from its features and benefits to installation and maintenance.

What is the Schneider A9F77220?

it is a high-performance miniature circuit breaker designed for various electrical applications. It is part of Schneider Electric’s Acti9 series, known for its reliability and advanced protection capabilities.

Technical Specifications

it boasts impressive specifications, including:

  • Rated Current: 20A
  • Breaking Capacity: 10kA
  • Number of Poles: 2
  • Voltage: 230/400V AC

These specs ensure it can handle significant electrical loads while providing robust protection.

Key Features of Schneider A9F77220

High Performance

This circuit breaker offers excellent performance, ensuring your electrical systems remain operational even under heavy loads. It is designed to trip in the event of an overload or short circuit, preventing damage and enhancing safety.

Reliability and Safety

Schneider Electric prioritizes safety, and it is no exception. It features advanced safety mechanisms to protect against electrical faults, ensuring the safety of your equipment and personnel.

Compact Design

The compact and modular design of it makes it easy to integrate into various electrical systems without requiring extensive space.

Benefits of Using Schneider A9F77220

Enhanced Electrical Safety

One of the primary benefits of it is its ability to provide enhanced electrical safety. It effectively mitigates the risks of electrical fires and equipment damage.

Longevity and Durability

Built with high-quality materials, this circuit breaker is designed to last, offering long-term protection for your electrical systems.

Ease of Installation

it is user-friendly and straightforward to install, making it a favorite among electricians and DIY enthusiasts alike.

Applications of Schneider A9F77220

Residential Use

In homes, it ensures the safety of household electrical systems, protecting appliances and preventing electrical hazards.

Commercial Use

For commercial buildings, this circuit breaker is ideal for safeguarding complex electrical installations, ensuring continuous operation and safety.

Industrial Use

In industrial settings, it provides reliable protection for heavy-duty electrical equipment, minimizing downtime and maintenance costs.

Installation Guide for Schneider A9F77220

Pre-Installation Checks

Before installation, ensure you have all the necessary tools and have reviewed the installation manual. Verify that the electrical system is compatible with the circuit breaker.

Step-by-Step Installation Process

  1. Turn Off Power: Ensure the main power supply is off to avoid any electrical accidents.
  2. Mount the Circuit Breaker: Secure the A9F77220 in the distribution board.
  3. Connect Wires: Attach the wires to the corresponding terminals.
  4. Secure Connections: Tighten all connections to prevent loose wiring.
  5. Power On and Test: Turn the power back on and test the circuit breaker to ensure it operates correctly.

Post-Installation Testing

After installation, conduct a series of tests to confirm the circuit breaker is functioning as expected. Check for any signs of overheating or loose connections.

Maintenance Tips for Schneider A9F77220

Regular Inspection Routine

Regularly inspect the circuit breaker for any signs of wear or damage. This helps in early detection of potential issues.

Cleaning and Servicing

Keep the circuit breaker clean and free from dust and debris. Periodic servicing by a professional can help maintain its optimal performance.

Troubleshooting Common Issues

If the circuit breaker trips frequently, it may indicate an underlying issue. Check for overloading or short circuits and address these problems promptly.

Comparing Schneider A9F77220 with Other Circuit Breakers

Performance Comparison

Compared to other circuit breakers in its class, it offers superior performance, especially in terms of reliability and safety features.

Cost Comparison

While it might be slightly more expensive than some competitors, the added safety and durability justify the investment.

User Feedback

Users consistently praise it for its reliability and ease of installation, highlighting its value in various applications.

Frequently Asked Questions (FAQs) About Schneider A9F77220

What Makes Schneider A9F77220 Stand Out?

The combination of advanced safety features, robust performance, and ease of installation makes it a standout choice.

Can Schneider A9F77220 Be Used in Harsh Environments?

Yes, its durable construction allows it to operate effectively in harsh environments, making it versatile for various applications.

What is the Lifespan of Schneider A9F77220?

With proper maintenance, it can last many years, providing reliable protection throughout its lifespan.

SKU: A9F77220 Categories: , Brand:
Main
Device applicationDistribution
RangeActi9
Product nameActi9 iC60
product or component typeMiniature circuit-breaker
Device short nameIC60N
Poles description2P
Number of protected poles2
[In] rated current20 A
Network typeDC
AC
Trip unit technologyThermal-magnetic
Curve codeC
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
36 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
10 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation categoryCategory A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolationYes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
StandardsEN 60947-2
IEC 60898-1
IEC 60947-2
EN 60898-1
Quality labelsNF
Complementary
Network frequency50/60 Hz
Magnetic tripping limit8 x In +/- 20 %
[Ics] rated service breaking capacity15 kA 75 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
4.5 kA 75 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
4.5 kA 75 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
10 kA 100 % conforming to IEC 60947-2 – 72…125 V DC
10 kA 100 % conforming to EN 60947-2 – 72…125 V DC
Limitation class3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicatorYes
Control typeToggle
Local signallingTrip indicator
Mounting modeFixed
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
9 mm pitches4
Height85 mm
Width36 mm
Depth78.5 mm
net weight0.25 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Connections – terminalsSingle terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length14 mm for top or bottom connection
Tightening torque2 N.m top or bottom
earth-leakage protectionSeparate block
Environment
IP degree of protectionIP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage categoryIV
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Operating altitude0…2000 m
Ambient air temperature for operation-35…70 °C
ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.200 cm
Package 1 Width3.500 cm
Package 1 Length9.500 cm
Package 1 Weight226.000 g
Unit Type of Package 2BB1
Number of Units in Package 26
Package 2 Height2.800 cm
Package 2 Width30.000 cm
Package 2 Length20.000 cm
Package 2 Weight1.407 kg
Unit Type of Package 3S03
Number of Units in Package 366
Package 3 Height30.000 cm
Package 3 Width30.000 cm
Package 3 Length40.000 cm
Package 3 Weight16.202 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F77220 | Miniature circuit-breaker, Acti9 iC60N, 2P, 20 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)”