Schneider A9F77310 | Miniature circuit-breaker, Acti9 iC60N, 3P, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)

Original price was: 2,609.27 EGP.Current price is: 1,709.10 EGP.

Shipping calculated at checkout.
or
SKU: A9F77310 Categories: Brand:

Schneider A9F77310 | Miniature circuit-breaker, Acti9 iC60N, 3P, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)

Technical Specifications A9F77310

  • Model: A9F77310

  • Series: Acti9 iC60N

  • Device Type: Miniature Circuit Breaker (MCB)

  • Number of Poles: 3P (Triple Pole)

  • Rated Current (In): 10 A

  • Tripping Curve: C Curve (for general use; suitable for standard loads like lighting, sockets, small motors)

  • Rated Operational Voltage (Ue): 230/400 V AC

  • Breaking Capacity:

    • 6000 A according to IEC 60898-1

    • 10,000 A according to IEC 60947-2

  • Frequency: 50/60 Hz

  • Electrical Endurance: Up to 20,000 operations

  • Mechanical Endurance: Up to 20,000 operations

  • Mounting Type: DIN rail (35 mm)

  • Width: 6 modules (approx. 54 mm total width)

  • Terminal Capacity: 25 mm² rigid cables

  • Degree of Protection: IP20 (IP40 in enclosure)

  • Operating Temperature Range: -25°C to +70°C

  • Standards Compliance: IEC 60898-1, IEC 60947-2, RoHS compliant

  • Insulation Voltage (Ui): 500 V

  • Impulse Withstand Voltage (Uimp): 6 kV

Key Features:

  • Dual Standard Compliance: Suitable for both residential/commercial (IEC 60898-1) and industrial (IEC 60947-2) applications

  • C Curve Protection: Provides fast disconnection for moderate inrush currents (typically 5–10 times rated current)

  • High Breaking Capacity: Offers superior short-circuit protection for safer installations

  • Acti9 VisiSafe Technology: Ensures maximum safety for personnel during maintenance (when used with full Acti9 system)

  • Compact DIN Rail Design: Space-saving installation for control panels and distribution boards

  • Quick and Secure Connection: Optimized terminals for easy wiring and secure clamping

  • Wide Temperature Range: Reliable operation in harsh or high-temperature environments

  • Long Lifecycle: High mechanical and electrical durability for extended performance

  • Environmentally Friendly: RoHS compliant and recyclable materials used in design

Applications:

  • Residential and Commercial Buildings: Protection of lighting, socket outlets, and small appliances

  • Industrial Distribution Boards: Suitable for protecting control circuits and auxiliary devices

  • HVAC Systems: Commonly used to protect components like small motors and fans

  • Control Panels: Used for branch circuit protection in machinery or automation setups

  • Data Centers & IT Installations: Reliable protection for electronic and control systems

  • Retail & Office Spaces: Used in distribution panels for individual zones or equipment

  • Renewable Energy Systems: Can be integrated into solar inverter AC side protection setups

Main
Device application Distribution
Range Acti9
product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name IC60N
Poles description 3P
Number of protected poles 3
[In] rated current 10 A
Network type AC DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2
Standards EN 60898-1 IEC 60947-2 EN 60947-2 IEC 60898-1
Quality labels NF
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 15 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 27 kA 75 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 27 kA 75 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 125...180 V DC 10 kA 100 % conforming to EN 60947-2 - 125...180 V DC
Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
Local signalling Trip indicator
Mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 6
Height 85 mm
Width 54 mm
Depth 78.5 mm
Net weight 0.375 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.500 cm
Package 1 Width 5.500 cm
Package 1 Length 9.500 cm
Package 1 Weight 319.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 4
Package 2 Height 8.000 cm
Package 2 Width 9.800 cm
Package 2 Length 22.500 cm
Package 2 Weight 1.332 kg
Unit Type of Package 3 S03
Number of Units in Package 3 44
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 15.290 kg
Contractual warranty
Warranty 18 months

Reviews

There are no reviews yet.

Be the first to review “Schneider A9F77310 | Miniature circuit-breaker, Acti9 iC60N, 3P, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)”

Your email address will not be published. Required fields are marked

Schneider A9F77310 | Miniature circuit-breaker, Acti9 iC60N, 3P, 10 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2) Schneider A9F77310 | Miniature...

Original price was: 2,609.27 EGP.Current price is: 1,709.10 EGP.

In stock

Select at least 2 products
to compare