Schneider A9F87132 Description

Circuit breakers are essential components in electrical systems, ensuring the safety and smooth operation of various installations. Among the diverse range of circuit breakers available in the market, the Schneider A9F87132 stands out for its exceptional features and performance.

1. Introduction to Schneider A9F87132 Circuit Breaker

The Schneider A9F87132 is a miniature circuit breaker designed to protect electrical circuits from overloads and short circuits. Manufactured by Schneider Electric, a global leader in energy management and automation solutions, this circuit breaker offers reliable protection for residential, commercial, and industrial applications.

2. Understanding Circuit Breakers

What is a circuit breaker?

A circuit breaker is a device that automatically interrupts electrical flow in a circuit when it detects abnormalities such as overcurrent or short circuits. It acts as a crucial safety mechanism, preventing electrical fires and equipment damage.

Importance of circuit breakers in electrical systems

Circuit breakers play a vital role in maintaining the integrity of electrical systems by safeguarding against potentially hazardous situations. Without proper protection, excessive current flow can lead to overheating, insulation damage, and even electrical fires.

3. Features of Schneider A9F87132 Circuit Breaker

The Schneider A9F87132 circuit breaker is equipped with several features that make it a preferred choice among professionals:

  • Compact design: The compact size of the A9F87132 allows for easy installation in confined spaces, making it ideal for both new construction and retrofit projects.
  • High breaking capacity: With a high breaking capacity of up to 6 kA, this circuit breaker can effectively handle short-circuit currents, ensuring reliable protection for electrical installations.
  • Quick tripping mechanism: The A9F87132 features a rapid tripping mechanism that responds swiftly to overloads and short circuits, minimizing downtime and reducing the risk of damage to connected equipment.
  • Compatibility with various installations: This circuit breaker is compatible with a wide range of installations, including single-phase and three-phase systems, making it versatile for different applications.

4. Applications of Schneider A9F87132 Circuit Breaker

The Schneider A9F87132 circuit breaker finds widespread use across various sectors:

  • Residential buildings: It provides reliable protection for household electrical circuits, including lighting, appliances, and outlets.
  • Commercial establishments: From office buildings to retail stores, the A9F87132 ensures the safety of electrical systems in commercial settings.
  • Industrial settings: In industrial environments where heavy machinery and equipment are in operation, this circuit breaker offers robust protection against electrical faults.

5. Installation and Maintenance Tips

Proper installation and regular maintenance are essential for ensuring the optimal performance of the Schneider A9F87132 circuit breaker:

  • Proper installation procedures: Follow manufacturer guidelines and local electrical codes when installing the A9F87132 to ensure safe and reliable operation.
  • Regular maintenance checks: Periodic inspections and testing help identify any potential issues early on and prevent unexpected failures.

6. Advantages of Choosing Schneider A9F87132

Choosing the Schneider A9F87132 circuit breaker offers several advantages:

  • Enhanced safety: With its advanced protective features, the A9F87132 enhances the safety of electrical installations, reducing the risk of accidents and injuries.
  • Reliable performance: Schneider Electric is known for its high-quality products, and the A9F87132 is no exception, delivering consistent performance and durability.
  • Cost-effectiveness: Despite its advanced features, the A9F87132 is competitively priced, offering excellent value for money compared to other circuit breakers in its class.

7. Comparison with Other Circuit Breakers

When comparing the Schneider A9F87132 with other circuit breakers, several factors come into play:

  • Size and dimensions: The compact design of the A9F87132 makes it suitable for installations where space is limited, giving it an edge over larger, bulkier models.
  • Breaking capacity: With its high breaking capacity, the A9F87132 outperforms many other circuit breakers in its category, providing superior protection against short circuits.
  • Tripping speed: The quick tripping mechanism of the A9F87132 ensures rapid response to electrical faults, minimizing the risk of damage to connected equipment compared to slower-acting breakers.

8. Customer Reviews and Feedback

Customers who have used the Schneider A9F87132 circuit breaker have generally provided positive feedback:

  • Positive experiences: Many users appreciate the reliability and performance of the A9F87132, citing its ease of installation and effectiveness in protecting electrical circuits.
  • Suggestions for improvement: Some users have suggested minor improvements, such as enhanced documentation and labeling, to make installation and maintenance procedures even more straightforward.

9. Conclusion

In conclusion, the Schneider A9F87132 circuit breaker offers a reliable and cost-effective solution for protecting electrical circuits in various applications. With its compact design, high breaking capacity, and quick tripping mechanism, it provides enhanced safety and performance compared to other circuit breakers in its class. Whether for residential, commercial, or industrial use, the A9F87132 is a trusted choice for professionals seeking dependable electrical protection.

FAQs:

  1. Is the Schneider A9F87132 suitable for outdoor installations?
    • Yes, the A9F87132 is suitable for outdoor installations provided it is installed in a weatherproof enclosure.
  2. What is the maximum current rating of the Schneider A9F87132?
    • The maximum current rating of the A9F87132 is 32 amps.
  3. Can the Schneider A9F87132 be used in three-phase systems?
    • Yes, the A9F87132 is compatible with both single-phase and three-phase systems.
  4. Does the Schneider A9F87132 come with a warranty?
    • Yes, Schneider Electric offers a warranty on the A9F87132 circuit breaker, providing added peace of mind for customers.
SKU: A9F87132 Category:
Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60H
Poles description 1P
Number of protected poles 1
[In] rated current 32 A
Network type AC
DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
15 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
30 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
20 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards EN 60898-1
EN 60947-2
IEC 60947-2
IEC 60898-1
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 21 kA 50 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
21 kA 50 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7500 A 75 % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500 A 75 % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
15 kA 50 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15 kA 50 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
15 kA 100 % conforming to EN 60947-2 – 72 V DC
15 kA 100 % conforming to IEC 60947-2 – 72 V DC
20 kA 100 % conforming to EN 60947-2 – 12…60 V DC
20 kA 100 % conforming to IEC 60947-2 – 12…60 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling Trip indicator
Mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 2
height 85 mm
Width 18 mm
Depth 78.5 mm
Net weight 0.215 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 3.5 N.m top or bottom
earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.8 cm
Package 1 Width 7.5 cm
Package 1 Length 9.4 cm
Package 1 Weight 120.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 7.9 cm
Package 2 Width 9.8 cm
Package 2 Length 22.4 cm
Package 2 Weight 1.499 kg
Unit Type of Package 3 S03
Number of Units in Package 3 132
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 16.976 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : A9F87132

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F87132 | Miniature circuit-breaker, Acti9 iC60H, 1P, 32 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024