Technical Specifications A9F87410

  • Product Type: Miniature Circuit Breaker (MCB)

  • Series: Acti9 iC60H

  • Reference Code: A9F87410

  • Number of Poles: 4P (Four-pole)

  • Rated Current (In): 10 A

  • Tripping Curve: C Curve (suitable for moderate inductive loads)

  • Breaking Capacity:

    • 10 kA according to IEC 60898-1

    • 15 kA according to IEC 60947-2

  • Rated Operational Voltage: 400/415 V AC

  • Frequency: 50/60 Hz

  • Degree of Protection: IP20 (higher with enclosure)

  • Mechanical Endurance: Up to 20,000 operations

  • Electrical Endurance: Up to 10,000 operations under load

  • Mounting: DIN rail mounting

  • Isolation Class: Class II (double insulation)

. Key Features

  • High Breaking Capacity: Offers strong short-circuit protection with a high interrupting capacity, ensuring electrical safety even in demanding environments.

  • C Curve Sensitivity: Designed to trip between 5 to 10 times the rated current, suitable for loads with moderate inrush currents such as motors and transformers.

  • Compact and Modular: Space-saving design suitable for modern distribution boards.

  • Easy Installation: Compatible with standard DIN rail mounting systems.

  • Reliable Indicators: Part of the Acti9 system, featuring clear status indicators for trip position and safe disconnection.

  • Environmentally Friendly: Made with recyclable materials and compliant with environmental standards.

  • Accessory Compatibility: Supports a wide range of add-ons including auxiliary contacts, earth leakage modules, and remote control devices.

. Applications

The Schneider A9F87410 MCB is versatile and can be used in various sectors, including:

a. Residential Applications

  • Protection of lighting circuits, sockets, and household appliances.

  • Ensures safety from overcurrents and short circuits in home installations.

b. Commercial Buildings

  • Widely used in malls, office complexes, and hotels to protect HVAC systems, elevators, lighting, and general power circuits.

c. Industrial Installations

  • Ideal for protecting small motors, control panels, and distribution boards in manufacturing facilities and workshops.

d. Electrical Distribution Boards

  • A preferred choice for sub-panels and main distribution boards due to its performance and compact size.

e. Renewable Energy Systems

  • Can be integrated into solar PV systems and wind installations to protect AC circuits in hybrid or grid-tied setups.

SKU: A9F87410 Category: Brand:
Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60H
Poles description 4P
Number of protected poles 4
[In] rated current 10 A
Network type AC
DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
42 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
30 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards IEC 60947-2
EN 60898-1
IEC 60898-1
EN 60947-2
Quality labels NF
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 15 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 50 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
5 kA 50 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
15 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 50 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
5 kA 50 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
7500 A 75 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500 A 75 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
21 kA 50 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
21 kA 50 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
15 kA 100 % conforming to IEC 60947-2 – 180…250 V DC
15 kA 100 % conforming to EN 60947-2 – 180…250 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling Trip indicator
Mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 8
height 85 mm
Width 72 mm
Depth 78.5 mm
Net weight 0.5 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.5 cm
Package 1 Width 7.0 cm
Package 1 Length 9.4 cm
Package 1 Weight 438.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 3
Package 2 Height 2.9 cm
Package 2 Width 30.0 cm
Package 2 Length 20.0 cm
Package 2 Weight 1.378 kg
Unit Type of Package 3 S03
Number of Units in Package 3 33
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 15.64 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F87410 | Miniature circuit-breaker, Acti9 iC60H, 4P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close
Let's Chat