-34%

Schneider A9F87463 | Miniature circuit-breaker, Acti9 iC60H, 4P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)

Schneider Electric
Availability:

In stock


Schneider A9F87463 | Miniature circuit-breaker, Acti9 iC60H, 4P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)

4,321.60 EGP 6,597.86 EGP

In stock

Compare

Schneider A9F87463 | Miniature circuit-breaker, Acti9 iC60H, 4P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)

1. Technical Specifications A9F87463

  • Product Series: Acti9 iC60H

  • Model Number: A9F87463

  • Type: Miniature Circuit Breaker (MCB)

  • Number of Poles: 4P (Four Pole)

  • Rated Current (In): 63 Amps

  • Tripping Curve: C Curve (ideal for general-purpose loads)

  • Breaking Capacity (IEC 60898-1): 10,000 A

  • Breaking Capacity (IEC 60947-2): 15,000 A

  • Rated Voltage: Up to 400/415V AC

  • Mounting Type: DIN Rail

  • Standards Compliance: IEC 60898-1, IEC 60947-2

  • Weight: Approximately 0.5 kg

2. Key Features

  • Provides reliable protection against short-circuits and overloads.

  • High-performance breaking capacity suitable for industrial and commercial use.

  • Features VisiSafe technology for enhanced safety during maintenance.

  • Compatible with a wide range of Acti9 accessories and modular devices.

  • Easy installation on standard DIN rails.

  • Compact and durable design with long service life.

  • Designed to function efficiently in various environmental conditions.

3. Applications

  • Main and sub-distribution electrical panels.

  • Residential, commercial, and industrial buildings.

  • Suitable for protecting electrical loads such as pumps, HVAC systems, and lighting circuits.

  • Used in smart energy systems and solar power applications.

  • Ideal for installations requiring high levels of electrical safety and reliability.

SKU: A9F87463 Category: Brand:
Main
Device applicationDistribution
RangeActi9
Product nameActi9 iC60
Product or component typeMiniature circuit-breaker
Device short nameiC60H
Poles description4P
Number of protected poles4
[In] rated current63 A
Network typeDC
AC
Trip unit technologyThermal-magnetic
Curve codeC
Breaking capacity10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
42 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
30 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
Utilisation categoryCategory A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolationYes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
StandardsEN 60898-1
EN 60947-2
IEC 60947-2
IEC 60898-1
Quality labelsNF
Complementary
Network frequency50/60 Hz
Magnetic tripping limit8 x In +/- 20 %
[Ics] rated service breaking capacity15 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 50 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
5 kA 50 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
15 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 50 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
5 kA 50 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
7500 A 75 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500 A 75 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
21 kA 50 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
21 kA 50 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
15 kA 100 % conforming to IEC 60947-2 – 180…250 V DC
15 kA 100 % conforming to EN 60947-2 – 180…250 V DC
Limitation class3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicatorYes
control typeToggle
local signallingTrip indicator
Mounting modeFixed
mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
9 mm pitches8
height85 mm
Width72 mm
Depth78.5 mm
Net weight0.5 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Connections – terminalsSingle terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexible
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
earth-leakage protectionSeparate block
Environment
IP degree of protectionIP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage categoryIV
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Operating altitude0…2000 m
ambient air temperature for operation-35…70 °C
Ambient air temperature for storage-40…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.3 cm
Package 1 Width7.1 cm
Package 1 Length8.5 cm
Package 1 Weight537.0 g
Unit Type of Package 2BB1
Number of Units in Package 23
Package 2 Height8.2 cm
Package 2 Width9.8 cm
Package 2 Length22.4 cm
Package 2 Weight1.672 kg
Unit Type of Package 3S03
Number of Units in Package 333
Package 3 Height30.0 cm
Package 3 Width30.0 cm
Package 3 Length40.0 cm
Package 3 Weight18.88 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F87463 | Miniature circuit-breaker, Acti9 iC60H, 4P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close
Let's Chat