Let's Chat
-35%

schneider A9F94116 | Miniature circuit-breaker, Acti9 iC60L, 1P, 16 A, C curve, 6000 A (IEC 60898-1), 25 kA (IEC 60947-2)

Schneider Electric
Availability:

In stock


632 EGP 964 EGP

In stock

Compare

schneider A9F94116 | Miniature circuit-breaker, Acti9 iC60L, 1P, 16 A, C curve, 6000 A (IEC 60898-1), 25 kA (IEC 60947-2)

schneider A9F94116 description

Introduction

Circuit breakers are vital components in any electrical system, providing essential protection against overcurrents and short circuits. This article will focus on the Schneider A9F94116, a miniature circuit breaker (MCB) that combines reliability with advanced features for effective circuit protection.

Schneider A9F94116

The Schneider A9F94116 is a 2-pole, 16A MCB from the Acti9 series, featuring a C curve. This MCB is designed to handle moderate inrush currents, making it suitable for a variety of applications in residential and commercial settings. The 2-pole design allows for protection of both live and neutral wires, enhancing its versatility.

How Circuit Breakers Work

Circuit breakers are safety devices that protect electrical systems by interrupting the power supply when they detect an overcurrent or short circuit. They continuously monitor the current flow and trip to stop electricity when irregularities are detected, thus preventing potential damage and ensuring system safety.

Types of Circuit Breakers

Circuit breakers come in various types, including Miniature Circuit Breakers (MCBs), Residual Current Circuit Breakers (RCCBs), and others. Each type serves a specific purpose, from protecting against overloads and short circuits to detecting residual currents that could indicate a fault.

Importance in Safety

The importance of circuit breakers in maintaining electrical safety cannot be overstated. They help prevent fires, damage to equipment, and electric shocks by interrupting circuits during overloads and short circuits. Properly functioning circuit breakers are crucial for ensuring the safety and longevity of electrical systems.

Installation Process

To install the Schneider A9F94116 circuit breaker, follow these steps:

  1. Turn off the main power: Ensure the main power supply is turned off to prevent any accidents.
  2. Identify the circuit: Determine the circuit where the MCB will be installed.
  3. Connect the MCB: Attach the MCB to the circuit, ensuring all connections are secure and correctly configured.
  4. Test the installation: After installation, test the MCB to ensure it trips and resets correctly.

Maintenance Tips

Regular maintenance is key to ensuring the continued effectiveness of your circuit breaker:

  1. Periodic testing: Regularly test the MCB to verify that it operates correctly.
  2. Inspect for damage: Check for any physical damage or signs of wear.
  3. Replace faulty units: If the MCB shows signs of malfunction, replace it promptly to maintain safety.

Common FAQs

  1. What is the difference between an MCB and an RCCB?
    • An MCB protects against overloads and short circuits, while an RCCB detects residual currents to prevent electric shocks.
  2. Can MCBs be used in residential applications?
    • Yes, MCBs like the Schneider A9F94116 are suitable for both residential and commercial applications.
  3. What does the ‘C curve’ mean in an MCB?
    • The ‘C curve’ refers to the MCB’s tripping characteristics, suitable for circuits with moderate inrush currents.
  4. How often should an MCB be tested?
    • It is recommended to test MCBs at least once a year to ensure they are functioning properly.
  5. Are MCBs affected by environmental factors?
    • Yes, environmental factors such as temperature and humidity can impact MCB performance, so it is important to consider the installation environment.

Conclusion

The Schneider A9F94116 MCB offers reliable protection for electrical circuits, especially those with moderate inrush currents. Proper installation and regular maintenance ensure its effectiveness in safeguarding your electrical systems.

SKU: A9F94116 Category:
brands

Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
product or component type Miniature circuit-breaker
Device short name iC60L
poles description 1P
Number of protected poles 1
[In] rated current 16 A
Network type DC
AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 15000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
50 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
25 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
25 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards EN 60898-1
IEC 60947-2
EN 60947-2
IEC 60898-1
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 12.5 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
12.5 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
35 kA 50 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
35 kA 50 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
25 kA 50 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
25 kA 50 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
7500 A 50 % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500 A 50 % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
20 kA 100 % conforming to EN 60947-2 – 72 V DC
20 kA 100 % conforming to IEC 60947-2 – 72 V DC
25 kA 100 % conforming to EN 60947-2 – 12…60 V DC
25 kA 100 % conforming to IEC 60947-2 – 12…60 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 2
Height 85 mm
Width 18 mm
Depth 78.5 mm
net weight 0.215 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.3 cm
Package 1 Width 1.8 cm
Package 1 Length 8.5 cm
Package 1 Weight 113.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.1 cm
Package 2 Width 9.8 cm
Package 2 Length 22.4 cm
Package 2 Weight 1.422 kg
Unit Type of Package 3 S03
Number of Units in Package 3 132
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 16.13 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : A9F94116

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “schneider A9F94116 | Miniature circuit-breaker, Acti9 iC60L, 1P, 16 A, C curve, 6000 A (IEC 60898-1), 25 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024