-34%

Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)

Schneider Electric
Availability:

In stock


Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)

631.70 EGP 964.40 EGP

In stock

Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)

1. Technical Specifications A9F94132

  • Product Series: Acti9 iC60L

  • Model Number: A9F94132

  • Type: Miniature Circuit Breaker (MCB)

  • Number of Poles: 1P (Single Pole)

  • Rated Current (In): 32 Amps

  • Tripping Curve: C Curve (suited for moderate inrush current)

  • Breaking Capacity (IEC 60898-1): 15,000 A

  • Breaking Capacity (IEC 60947-2): 20,000 A

  • Rated Voltage: 230/240V AC (single-phase)

  • Mounting: DIN rail (standard)

  • Compliance Standards: IEC 60898-1, IEC 60947-2

  • Approximate Weight: 120–150 grams

2. Key Features

  • High breaking capacity ensures reliable protection even in fault-prone networks.

  • C curve tripping characteristic balances sensitivity and selectivity, perfect for general loads.

  • Quick and secure mounting using standard DIN rail systems.

  • Designed for use with Acti9 accessories such as auxiliaries and terminal covers.

  • Includes VisiSafe technology, providing visible disconnection for safer maintenance.

  • Robust construction for long-term electrical and mechanical endurance.

3. Applications

  • Used in residential, commercial, and light industrial settings.

  • Suitable for protecting circuits with moderate load surges, like lighting, appliances, and small motors.

  • Ideal for use in control panels, distribution boards, and automation systems.

  • Offers dependable protection in environments where short-circuit risks are moderate to high.

  • A solid choice for compliance with international safety and performance standards.

 

SKU: A9F94132 Category: Brand:
Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60L
Poles description 1P
Number of protected poles 1
[In] rated current 32 A
Network type DC
AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 15000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
20 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
25 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards IEC 60947-2
EN 60947-2
EN 60898-1
IEC 60898-1
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 35 kA 50 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
10 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
35 kA 50 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
10 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
18 kA 50 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
18 kA 50 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
7500 A 50 % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500 A 50 % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
20 kA 100 % conforming to EN 60947-2 – 72 V DC
20 kA 100 % conforming to IEC 60947-2 – 72 V DC
25 kA 100 % conforming to EN 60947-2 – 12…60 V DC
25 kA 100 % conforming to IEC 60947-2 – 12…60 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling Trip indicator
Mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 2
height 85 mm
Width 18 mm
Depth 78.5 mm
Net weight 0.215 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 3.5 N.m top or bottom
earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.500 cm
Package 1 Width 1.800 cm
Package 1 Length 9.500 cm
Package 1 Weight 124.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.000 cm
Package 2 Width 9.800 cm
Package 2 Length 22.500 cm
Package 2 Weight 1.555 kg
Unit Type of Package 3 S03
Number of Units in Package 3 132
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 17.700 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close
Let's Chat