Let's Chat
-35%

Schneider A9F94316 | Miniature circuit-breaker, Acti9 iC60L, 3P, 16 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)

Schneider Electric
Availability:

In stock


2,632 EGP 4,018 EGP

In stock

Compare

Schneider A9F94316 | Miniature circuit-breaker, Acti9 iC60L, 3P, 16 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)

Description Schneider A9F94316

General Description

The Schneider A9F94316 is a high-performance circuit breaker designed to provide reliable protection for electrical systems. Part of the Acti9 series, this miniature circuit breaker (MCB) is specifically engineered to meet the needs of both residential and commercial applications. It combines advanced technology with robust construction, ensuring superior performance and safety.

Key Features

  • High Breaking Capacity: Capable of handling significant current loads without failure.
  • Compact Design: Space-saving design that fits easily into standard distribution boards.
  • Easy Installation: User-friendly features that simplify the installation process.
  • Safety Mechanisms: Includes advanced protection features to safeguard against electrical hazards.

Technical Specifications

Electrical Specifications

  • Rated Operational Voltage: Up to 240/415V AC
  • Rated Current: 16A
  • Breaking Capacity: 10kA according to IEC/EN 60947-2

Mechanical Specifications

  • Mounting: DIN rail mounting for ease of installation
  • Dimensions: 18mm width per pole
  • Weight: Approximately 125g

Environmental Specifications

  • Operating Temperature: -25°C to +70°C
  • Storage Temperature: -40°C to +85°C
  • Resistance: High resistance to humidity and corrosive environments

Design and Construction

Materials Used

The Schneider A9F94316 is constructed using high-quality, flame-retardant materials that ensure durability and safety. The casing is made from tough polycarbonate, while the internal components are crafted from copper and silver alloys to enhance conductivity and reduce heat buildup.

Build Quality

Attention to detail is evident in the build quality of the Schneider A9F94316. Each component is precision-engineered to ensure a tight fit and optimal performance. The robust construction minimizes the risk of mechanical failure, even under demanding conditions.

Durability

Designed to last, the Schneider A9F94316 can withstand harsh operating environments. Its resilient construction ensures long-term reliability, making it a cost-effective choice for both residential and commercial installations.

Functionality

How It Works

The Schneider A9F94316 operates by automatically disconnecting the electrical circuit when an overload or short circuit is detected. This prevents potential damage to the wiring and connected devices. The MCB can be manually reset after the fault is cleared, restoring normal operation.

Typical Applications

  • Residential: Protects household circuits from overcurrent and short circuits.
  • Commercial: Ensures the safety of electrical systems in offices, retail spaces, and other commercial buildings.
  • Industrial: Suitable for use in light industrial applications where reliable circuit protection is essential.

Advantages of Using Schneider A9F94316

Safety Features

Safety is paramount with the Schneider A9F94316. It includes a range of features designed to protect both people and property. These include overcurrent protection, short circuit protection, and a fail-safe mechanism that ensures the MCB operates correctly even under fault conditions.

Reliability

Schneider Electric’s reputation for reliability is well-earned, and the A9F94316 is no exception. It offers consistent performance, reducing the risk of unexpected outages and maintenance issues.

Energy Efficiency

By preventing electrical faults, the Schneider A9F94316 helps improve the overall energy efficiency of the system. This not only reduces energy waste but also lowers electricity bills, making it an environmentally and economically smart choice.

Installation Process

Pre-installation Requirements

Before installing the Schneider A9F94316, it’s important to ensure that the electrical system is properly prepared. This includes verifying the load requirements, ensuring compatibility with existing wiring, and following all safety protocols.

Step-by-Step Guide

  1. Turn off the Main Power Supply: Safety first—ensure the main power supply is switched off before beginning the installation.
  2. Mount the MCB on the DIN Rail: Securely attach the MCB to the DIN rail in the distribution board.
  3. Connect the Wires: Follow the wiring diagram to connect the incoming and outgoing wires to the MCB.
  4. Tighten the Connections: Use a screwdriver to tighten all terminal screws, ensuring a secure connection.
  5. Test the Installation: Turn the main power back on and test the MCB to ensure it operates correctly.

Maintenance and Troubleshooting

Routine Maintenance Tips

  • Regular Inspections: Periodically inspect the MCB for signs of wear or damage.
  • Clean the Terminals: Keep the terminals clean and free from dust and debris.
  • Check Tightness: Ensure all terminal screws remain tight to prevent loose connections.

Common Issues and Solutions

  • Frequent Tripping: This may indicate an overload or short circuit. Check the connected devices and wiring for faults.
  • MCB Not Resetting: Ensure there is no ongoing fault in the circuit before attempting to reset the MCB.
  • Overheating: This could be due to a loose connection or an overload. Inspect and rectify as necessary.

Comparing Schneider A9F94316 with Other Models

Comparison with Similar Products

When compared to other MCBs in the market, the Schneider A9F94316 stands out for its high breaking capacity, compact design, and advanced safety features. It offers superior performance in both residential and commercial settings.

Unique Selling Points

  • High Durability: Built to withstand tough conditions.
  • Easy Installation: User-friendly design simplifies the installation process.
  • Reliable Performance: Consistently protects against electrical faults.

Customer Reviews and Feedback

Positive Feedback

Customers frequently praise the Schneider A9F94316 for its reliability and ease of installation. Many appreciate the peace of mind that comes with using a trusted brand like Schneider Electric.

Constructive Criticism

Some users have noted that the MCB can be slightly more expensive than other brands. However, they often acknowledge that the higher cost is justified by the superior quality and performance.

Cost and Value for Money

Pricing Information

The price of the Schneider A9F94316 can vary depending on the supplier and region. On average, it falls within a competitive price range for high-quality MCBs.

Cost vs. Benefits Analysis

While the initial cost may be higher than some alternatives, the long-term benefits of using the Schneider A9F94316—such as enhanced safety, reliability, and energy efficiency—make it a worthwhile investment.

Where to Buy Schneider A9F94316

Authorized Dealers

Purchasing from authorized Schneider Electric dealers ensures you receive a genuine product with full warranty coverage. Check Schneider Electric’s official website for a list of authorized dealers in your area.

Online Platforms

The Schneider A9F94316 is also available from various online platforms, including major e-commerce sites. Ensure you buy from reputable sellers to avoid counterfeit products.

SKU: A9F94316 Category:
Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60L
Poles description 3P
Number of protected poles 3
[In] rated current 16 A
Network type AC
DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards IEC 60898-1
EN 60898-1
IEC 60947-2
EN 60947-2
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 12.5 kA 50 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
10 kA 50 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
12.5 kA 50 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
10 kA 50 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
25 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
25 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
35 kA 50 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
35 kA 50 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
7500 A 50 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500 A 50 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
20 kA 100 % conforming to EN 60947-2 – 125…180 V DC
20 kA 100 % conforming to IEC 60947-2 – 125…180 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling Trip indicator
Mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 6
height 85 mm
Width 54 mm
Depth 78.5 mm
Net weight 0.375 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.5 cm
Package 1 Width 7.5 cm
Package 1 Length 9.5 cm
Package 1 Weight 338 g
Unit Type of Package 2 BB1
Number of Units in Package 2 4
Package 2 Height 8 cm
Package 2 Width 10 cm
Package 2 Length 22.5 cm
Package 2 Weight 1.412 kg
Unit Type of Package 3 S03
Number of Units in Package 3 44
Package 3 Height 30 cm
Package 3 Width 30 cm
Package 3 Length 40 cm
Package 3 Weight 15.92 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : A9F94316

SHOPPING CART