Specifications Schneider A9F94410

  • Model: A9F94410

  • Type: Miniature Circuit-Breaker (MCB)

  • Series: Acti9 iC60L

  • Poles: 4P (Four Poles)

  • Rated Current: 10 Amps

  • Curve Type: C Curve (for moderate inrush current)

  • Breaking Capacity:

    • 15 kA (at 415 VAC, IEC 60898-1)

    • 25 kA (at 415 VAC, IEC 60947-2)

  • Standards Compliance:

    • IEC 60898-1 (Standard for residential and light commercial electrical installations)

    • IEC 60947-2 (Standard for low-voltage circuit breakers)

  • Voltage: Suitable for 230/415 VAC systems

Features Schneider A9F94410

  1. High Breaking Capacity:

    • The 15 kA breaking capacity (at 415 VAC) according to IEC 60898-1 and the 25 kA capacity according to IEC 60947-2 ensures that the Acti9 iC60L circuit breaker can handle high fault currents, providing effective protection against both overloads and short circuits in industrial and residential installations.

  2. C Curve:

    • The C curve type means the circuit breaker trips between 5 to 10 times the rated current. This is ideal for protecting circuits that have moderate inrush currents, such as lighting circuits, heating systems, and motors with typical startup characteristics.

  3. Four-Pole Design (4P):

    • The 4P (four-pole) configuration is perfect for protecting three-phase systems with a neutral, typically found in complex or industrial electrical installations. It ensures balanced protection across all phases, including the neutral wire.

  4. Thermal-Magnetic Trip Mechanism:

    • The thermal-magnetic trip unit provides both overload protection (thermal) and short-circuit protection (magnetic), making this breaker versatile and highly effective for both gradual overloads and immediate fault conditions.

  5. Compact and Space-Saving Design:

    • The Acti9 iC60L is designed to be compact, which allows it to be easily installed in standard distribution boards and electrical panels, saving valuable space while still offering high performance and protection.

  6. Long Life and Reliability:

    • Schneider’s Acti9 range is designed for long-term durability, with the iC60L providing reliable operation in both normal and fault conditions, ensuring continued protection over an extended service life.

  7. Standards Compliance:

    • The breaker complies with both IEC 60898-1 for residential and light commercial applications and IEC 60947-2 for industrial installations, ensuring high standards of performance and safety.

Applications:

  • Industrial Electrical Systems: Ideal for use in three-phase systems with a neutral in industrial settings, where high reliability and protection are needed for critical machinery and equipment.

  • Commercial Installations: Suitable for offices, retail spaces, and commercial buildings with complex electrical distribution systems requiring four-pole protection.

  • Residential Installations: Can be used in residential buildings, especially in systems where four-pole protection is required, such as certain types of air conditioning units, heating systems, or motor-driven appliances.

  • Motor Protection: Offers protection for motors and other equipment that may have moderate inrush currents during startup, ensuring protection without unnecessary tripping.

  • Power Distribution Panels: Commonly used in low-voltage electrical panels and distribution boards to protect circuits from short circuits and overloads.

brands

Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60L
poles description 4P
Number of protected poles 4
[In] rated current 10 A
network type AC
DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
70 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
25 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards EN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 12.5 kA 50 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
10 kA 50 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
12.5 kA 50 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
10 kA 50 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
25 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
25 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
35 kA 50 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
35 kA 50 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
7500 A 50 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500 A 50 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
20 kA 100 % conforming to EN 60947-2 – 180…250 V DC
20 kA 100 % conforming to IEC 60947-2 – 180…250 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
Mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 8
Height 85 mm
Width 72 mm
Depth 78.5 mm
Net weight 0.5 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.500 cm
Package 1 Width 7.200 cm
Package 1 Length 9.400 cm
Package 1 Weight 439.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 3
Package 2 Height 8.000 cm
Package 2 Width 9.800 cm
Package 2 Length 22.500 cm
Package 2 Weight 1.379 kg
Unit Type of Package 3 S03
Number of Units in Package 3 33
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 15.670 kg
Contractual warranty
Warranty 18 months
Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60L
poles description 4P
Number of protected poles 4
[In] rated current 10 A
network type AC DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2
Standards EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 12.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 10 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 12.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 10 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 25 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 25 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 35 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 35 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 7500 A 50 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 50 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 20 kA 100 % conforming to EN 60947-2 - 180...250 V DC 20 kA 100 % conforming to IEC 60947-2 - 180...250 V DC
Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
Mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 8
Height 85 mm
Width 72 mm
Depth 78.5 mm
Net weight 0.5 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.500 cm
Package 1 Width 7.200 cm
Package 1 Length 9.400 cm
Package 1 Weight 439.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 3
Package 2 Height 8.000 cm
Package 2 Width 9.800 cm
Package 2 Length 22.500 cm
Package 2 Weight 1.379 kg
Unit Type of Package 3 S03
Number of Units in Package 3 33
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 15.670 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F94410 | Miniature circuit-breaker, Acti9 iC60L, 4P, 10 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024