Technical Specifications

  • Model Number: A9F95102
  • Series: Acti9 iC60L
  • Breaker Type: Miniature Circuit Breaker (MCB)
  • Number of Poles: 1P (Single-Pole)
  • Rated Current: 2A
  • Tripping Curve: K Curve (for high inrush current loads)
  • Breaking Capacity:
    • 15kA (IEC/EN 60898-1 – Residential & Commercial Applications)
    • 100kA (IEC/EN 60947-2 – Industrial & High Fault Level Applications)
  • Voltage Rating: 230/400V AC
  • Frequency: 50/60 Hz
  • Mounting Type: DIN Rail Mounting
  • Ingress Protection: IP20 (when installed in an enclosure)
  • Compliance & Certifications:
    • IEC/EN 60898-1 (for residential & commercial electrical systems)
    • IEC/EN 60947-2 (for industrial & heavy-duty electrical systems)

Key Features

  1. K-Curve Tripping for High Inrush Current Loads

    • Specially designed to withstand high starting currents from inductive loads like motors, transformers, and solenoids without nuisance tripping.
    • Trips within 8 to 12 times the rated current, ensuring stable operation in demanding applications.
  2. Ultra-High Breaking Capacity (100kA)

    • Offers exceptional protection against short circuits, making it suitable for high-fault environments such as industrial plants and power stations.
  3. Single-Pole (1P) Design for Compact Installation

    • Ideal for protecting individual circuits, providing space-efficient integration into electrical panels.
  4. Advanced Safety Features with Acti9 Technology

    • VisiTrip Indicator for quick fault detection.
    • VisiSafe Technology ensures complete disconnection of the circuit for enhanced operator safety.
  5. Compact & Modular DIN Rail Mounting

    • Designed for quick installation in both new installations and retrofitting projects.
  6. Reliable Performance in Harsh Conditions

    • Built to withstand voltage fluctuations and harsh industrial conditions, ensuring long-term durability.
  7. Full Compliance with Global Standards

    • Meets both IEC 60898-1 (for residential & commercial use) and IEC 60947-2 (for industrial applications), ensuring wide usability.

Applications

  • Industrial Machinery Protection: Ideal for motors, transformers, and industrial control systems.
  • Power Distribution Panels: Used in commercial and industrial power networks for circuit protection.
  • Heavy-Duty Equipment: Protects equipment with high inrush currents without nuisance tripping.
  • Renewable Energy Systems: Suitable for solar power and battery storage applications.
  • Critical Infrastructure: Applied in data centers, medical facilities, and high-risk electrical environments.

brands

Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60L
poles description 1P
Number of protected poles 1
[In] rated current 2 A
network type AC
DC
Trip unit technology Thermal-magnetic
Curve code K
Breaking capacity 15000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
100 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
100 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
100 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
25 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Standards IEC 60947-2
EN 60947-2
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 12 x In +/- 20 %
[Ics] rated service breaking capacity 100 kA 100 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
100 kA 100 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
100 kA 100 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
100 kA 100 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
100 kA 100 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
100 kA 100 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
20 kA 100 % conforming to EN 60947-2 – 72 V DC
20 kA 100 % conforming to IEC 60947-2 – 72 V DC
25 kA 100 % conforming to EN 60947-2 – 12…60 V DC
25 kA 100 % conforming to IEC 60947-2 – 12…60 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
Mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 2
Height 85 mm
Width 18 mm
Depth 78.5 mm
Net weight 0.215 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0…2000 m
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.8 cm
Package 1 Width 7.5 cm
Package 1 Length 9.5 cm
Package 1 Weight 113.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.0 cm
Package 2 Width 9.8 cm
Package 2 Length 22.5 cm
Package 2 Weight 1.412 kg
Unit Type of Package 3 S03
Number of Units in Package 3 132
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 16.019 kg
Contractual warranty
Warranty 18 months
Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60L
poles description 1P
Number of protected poles 1
[In] rated current 2 A
network type AC DC
Trip unit technology Thermal-magnetic
Curve code K
Breaking capacity 15000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 100 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 100 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 25 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60947-2 Yes conforming to IEC 60947-2
Standards IEC 60947-2 EN 60947-2
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 12 x In +/- 20 %
[Ics] rated service breaking capacity 100 kA 100 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 100 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 100 kA 100 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 100 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 100 kA 100 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 100 kA 100 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 20 kA 100 % conforming to EN 60947-2 - 72 V DC 20 kA 100 % conforming to IEC 60947-2 - 72 V DC 25 kA 100 % conforming to EN 60947-2 - 12...60 V DC 25 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
Mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 2
Height 85 mm
Width 18 mm
Depth 78.5 mm
Net weight 0.215 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.8 cm
Package 1 Width 7.5 cm
Package 1 Length 9.5 cm
Package 1 Weight 113.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.0 cm
Package 2 Width 9.8 cm
Package 2 Length 22.5 cm
Package 2 Weight 1.412 kg
Unit Type of Package 3 S03
Number of Units in Package 3 132
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 16.019 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9F95102 | Miniature circuit breaker (MCB), Acti9 iC60L, 1P, 2A, K curve, 15000A (IEC/EN 60898-1), 100kA (IEC/EN 60947-2)”

There are no reviews yet.