Technical Specifications A9N18446

  • Reference Code: A9N18446

  • Product Type: Miniature Circuit Breaker (MCB)

  • Series: Acti9 C120H

  • Number of Poles: 1P (Single Pole)

  • Rated Current: 80 Amperes

  • Tripping Curve: Type C – designed for circuits with moderate inrush currents

  • Breaking Capacity (IEC 60898-1): 15,000 A

  • Breaking Capacity (IEC 60947-2): 15 kA

  • Rated Voltage: 230 V AC

  • Frequency: 50/60 Hz

  • Mounting Type: DIN rail mounted

  • Insulation Voltage: Up to 500 V

  • Degree of Protection: IP20 (when enclosed)

  • Standards Compliance: IEC 60898-1 and IEC 60947-2

Key Features:

  1. High Breaking Capacity
    With a 15 kA breaking capacity, this breaker offers enhanced protection in installations where high fault currents are possible.

  2. Compact Single-Pole Design
    Ideal for single-phase applications where space efficiency and individual circuit protection are essential.

  3. C Curve Performance
    Suitable for circuits with moderate surges, including lighting, motors, and mixed loads.

  4. Thermal and Magnetic Trip Units
    Provides dual protection – thermal for overload and magnetic for short circuit – ensuring operational safety.

  5. Reliable Operation
    Built to handle demanding electrical environments with consistent performance and long service life.

  6. Ease of Installation
    Fast and secure mounting on standard DIN rails, suitable for quick upgrades or replacements.

  7. Visual Indicators
    Clear status indicators provide fast diagnostics and improved maintenance response.

Applications:

  • Residential Electrical Systems
    Protects individual high-load circuits such as air conditioners, water heaters, or electric ovens.

  • Commercial Buildings
    Used in lighting and power distribution for retail stores, offices, and public infrastructure.

  • Industrial Panels
    Suitable for circuits feeding machinery or control systems with high safety requirements.

  • Control Panels
    Ensures protection for single-phase supply circuits in automation or HVAC systems.

  • Sensitive Electrical Zones
    Recommended for areas where enhanced breaking capacity is necessary to meet safety codes.

Main
Range of product C120
Range Acti9
Product name C120
Product or component type Miniature circuit-breaker
Device short name C120H
Device application Distribution
Poles description 1P
Number of protected poles 1
[In] rated current 80 A at 30 °C
Network type AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 30 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 12 V DC conforming to EN/IEC 60947-2
20 kA Icu at 125 V DC conforming to EN/IEC 60947-2
15 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2
15 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15000 A Icn at 230…400 V AC 50/60 Hz conforming to EN/IEC 60898-1
4.5 kA Icu at 380…415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2
30 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Complementary
Network frequency 50/60 Hz
[Ue] rated operational voltage 380…415 V AC 50/60 Hz
125 V DC
<= 144 V DC
12 V DC
220…240 V AC 50/60 Hz
230…400 V AC 50/60 Hz
130 V AC 50/60 Hz
12 V AC 50/60 Hz
Magnetic tripping limit 5…10 x In
[Ics] rated service breaking capacity 15 kA 50 % conforming to EN/IEC 60947-2 – 130 V AC 50/60 Hz
7.5 kA 50 % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
2.25 kA 50 % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
7500 A 50 % conforming to EN/IEC 60898-1 – 230…400 V AC 50/60 Hz
20 kA 100 % conforming to EN/IEC 60947-2 – 12 V DC
15 kA 100 % conforming to EN/IEC 60947-2 – <= 144 V DC
20 kA 100 % conforming to EN/IEC 60947-2 – 125 V DC
15 kA 50 % conforming to EN/IEC 60947-2 – 12 V AC 50/60 Hz
Limitation class 3 conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling ON/OFF indication
Mounting mode Clip-on
mounting support 35 mm symmetrical DIN rail
Comb busbar and distribution block compatibility YES
9 mm pitches 3
height 81 mm
Width 27 mm
Depth 73 mm
Net weight 0.205 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 5000 cycles conforming to IEC 60947-2
Locking options description Handle sealable with cable diameter 0.7mm in OFF or ON position
Connections – terminals Tunnel type terminals1…50 mm² rigid
Tunnel type terminals1.5…35 mm² flexible
Wire stripping length 15 mm
Tightening torque 3.5 N.m
earth-leakage protection Without
Environment
Standards EN/IEC 60947-2
EN/IEC 60898-1
product certifications EAC
IP degree of protection IP20 conforming to IEC 60529
Pollution degree 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 2000 m
ambient air temperature for operation -30…60 °C
Ambient air temperature for storage -40…70 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.500 cm
Package 1 Width 2.700 cm
Package 1 Length 8.600 cm
Package 1 Weight 193.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.600 cm
Package 2 Width 9.300 cm
Package 2 Length 33.400 cm
Package 2 Weight 2.376 kg
Unit Type of Package 3 S03
Number of Units in Package 3 72
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 14.737 kg
Contractual warranty
Warranty 18 months
Main
Range of product C120
Range Acti9
Product name C120
Product or component type Miniature circuit-breaker
Device short name C120H
Device application Distribution
Poles description 1P
Number of protected poles 1
[In] rated current 80 A at 30 °C
Network type AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 30 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12 V DC conforming to EN/IEC 60947-2 20 kA Icu at 125 V DC conforming to EN/IEC 60947-2 15 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 4.5 kA Icu at 380...415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2 30 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Complementary
Network frequency 50/60 Hz
[Ue] rated operational voltage 380...415 V AC 50/60 Hz 125 V DC <= 144 V DC 12 V DC 220...240 V AC 50/60 Hz 230...400 V AC 50/60 Hz 130 V AC 50/60 Hz 12 V AC 50/60 Hz
Magnetic tripping limit 5...10 x In
[Ics] rated service breaking capacity 15 kA 50 % conforming to EN/IEC 60947-2 - 130 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 2.25 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 7500 A 50 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz 20 kA 100 % conforming to EN/IEC 60947-2 - 12 V DC 15 kA 100 % conforming to EN/IEC 60947-2 - <= 144 V DC 20 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC 15 kA 50 % conforming to EN/IEC 60947-2 - 12 V AC 50/60 Hz
Limitation class 3 conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling ON/OFF indication
Mounting mode Clip-on
mounting support 35 mm symmetrical DIN rail
Comb busbar and distribution block compatibility YES
9 mm pitches 3
height 81 mm
Width 27 mm
Depth 73 mm
Net weight 0.205 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 5000 cycles conforming to IEC 60947-2
Locking options description Handle sealable with cable diameter 0.7mm in OFF or ON position
Connections - terminals Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible
Wire stripping length 15 mm
Tightening torque 3.5 N.m
earth-leakage protection Without
Environment
Standards EN/IEC 60947-2 EN/IEC 60898-1
product certifications EAC
IP degree of protection IP20 conforming to IEC 60529
Pollution degree 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 2000 m
ambient air temperature for operation -30…60 °C
Ambient air temperature for storage -40…70 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.500 cm
Package 1 Width 2.700 cm
Package 1 Length 8.600 cm
Package 1 Weight 193.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.600 cm
Package 2 Width 9.300 cm
Package 2 Length 33.400 cm
Package 2 Weight 2.376 kg
Unit Type of Package 3 S03
Number of Units in Package 3 72
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 14.737 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9N18446 | Miniature circuit-breaker, Acti9 C120H, 1P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024