-35%
, , ,

Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)

Schneider Electric
Availability:

In stock


 Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)

1,985.60 EGP 3,031.50 EGP

In stock

 Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)

Technical Specifications A9N18447

  • Reference Code: A9N18447

  • Product Type: Miniature Circuit Breaker (MCB)

  • Series: Acti9 C120H

  • Number of Poles: 1P (Single Pole)

  • Rated Current: 100 Amperes

  • Tripping Curve: Type C – suitable for moderate inrush currents such as those in motors or inductive loads

  • Breaking Capacity (IEC 60898-1): 15,000 A

  • Breaking Capacity (IEC 60947-2): 15 kA

  • Rated Voltage: 230 V AC

  • Frequency: 50/60 Hz

  • Mounting Type: DIN rail mounted

  • Insulation Voltage: Up to 500 V

  • Degree of Protection: IP20 (when installed in an enclosure)

  • Compliance: Conforms to IEC 60898-1 and IEC 60947-2

Key Features A9N18447

  1. High Breaking Capacity
    With a 15 kA breaking capacity, this breaker offers enhanced protection against large fault currents, making it suitable for demanding installations.

  2. Single-Pole Design
    Ideal for single-phase circuits, this breaker provides individual protection for each circuit, offering flexibility in design and safety.

  3. C Curve Response
    The C curve is designed to handle moderate inrush currents, which are typically experienced with motors, lighting, or other inductive loads.

  4. Thermal and Magnetic Protection
    The breaker is equipped with both thermal and magnetic tripping mechanisms to ensure protection against overloads and short circuits.

  5. Reliability and Durability
    Built to withstand tough electrical environments, the A9N18447 ensures long-term, consistent performance with minimal maintenance.

  6. Easy Installation
    Designed for quick mounting on standard DIN rails, allowing for easy integration into electrical distribution panels.

  7. Clear Visual Indicators
    Features clear status indicators for easier diagnostics and maintenance.

Applications:

  • Residential Circuits
    Ideal for protecting single-phase circuits in homes, such as lighting and high-load appliances like electric water heaters or air conditioning units.

  • Commercial Facilities
    Protects circuits in retail, office spaces, and public buildings, ensuring that electrical distribution systems are safe and reliable.

  • Industrial Power Panels
    Suitable for use in industrial control panels and electrical distribution systems where high fault current protection is essential.

  • Machinery and Equipment Protection
    Perfect for circuits that power machinery or heavy-duty equipment, protecting against overloads and short circuits.

  • HVAC and Automation Systems
    Can be used in HVAC systems and automation control panels, ensuring safe operation of sensitive electrical components.

Main
Range of product C120
Range Acti9
Product name C120
Product or component type Miniature circuit-breaker
Device short name C120H
Device application Distribution
Poles description 1P
Number of protected poles 1
[In] rated current 100 A at 30 °C
Network type AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 30 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 12 V DC conforming to EN/IEC 60947-2
20 kA Icu at 125 V DC conforming to EN/IEC 60947-2
15 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2
15 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15000 A Icn at 230…400 V AC 50/60 Hz conforming to EN/IEC 60898-1
4.5 kA Icu at 380…415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2
30 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Complementary
Network frequency 50/60 Hz
[Ue] rated operational voltage 380…415 V AC 50/60 Hz
125 V DC
<= 144 V DC
12 V DC
220…240 V AC 50/60 Hz
230…400 V AC 50/60 Hz
130 V AC 50/60 Hz
12 V AC 50/60 Hz
Magnetic tripping limit 5…10 x In
[Ics] rated service breaking capacity 15 kA 50 % conforming to EN/IEC 60947-2 – 130 V AC 50/60 Hz
7.5 kA 50 % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
2.25 kA 50 % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
7500 A 50 % conforming to EN/IEC 60898-1 – 230…400 V AC 50/60 Hz
20 kA 100 % conforming to EN/IEC 60947-2 – 12 V DC
15 kA 100 % conforming to EN/IEC 60947-2 – <= 144 V DC
20 kA 100 % conforming to EN/IEC 60947-2 – 125 V DC
15 kA 50 % conforming to EN/IEC 60947-2 – 12 V AC 50/60 Hz
Limitation class 3 conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2
Contact position indicator Yes
control type Toggle
local signalling ON/OFF indication
Mounting mode Clip-on
mounting support 35 mm symmetrical DIN rail
Comb busbar and distribution block compatibility NO
9 mm pitches 3
height 81 mm
Width 27 mm
Depth 73 mm
Net weight 0.205 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 5000 cycles conforming to IEC 60947-2
Locking options description Handle sealable with cable diameter 0.7mm in OFF or ON position
Connections – terminals Tunnel type terminals1…50 mm² rigid
Tunnel type terminals1.5…35 mm² flexible
Wire stripping length 15 mm
Tightening torque 3.5 N.m
earth-leakage protection Without
Environment
Standards EN/IEC 60898-1
EN/IEC 60947-2
product certifications EAC
IP degree of protection IP20 conforming to IEC 60529
Pollution degree 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 2000 m
ambient air temperature for operation -30…60 °C
Ambient air temperature for storage -40…70 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.500 cm
Package 1 Width 7.500 cm
Package 1 Length 8.500 cm
Package 1 Weight 193.400 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.500 cm
Package 2 Width 9.000 cm
Package 2 Length 33.000 cm
Package 2 Weight 2.378 kg
Unit Type of Package 3 S03
Number of Units in Package 3 72
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 14.685 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9N18447 | Miniature circuit-breaker, Acti9 C120H, 1P, 100 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)”

There are no reviews yet.