Schneider A9R41263 | Acti 9 iID – RCCB – 2P – 63A – 30mA – type AC

Schneider Electric
Availability:

Out of stock


4,345 EGP 6,033 EGP

Out of stock

Compare

Schneider A9R41263 | Acti 9 iID – RCCB – 2P – 63A – 30mA – type AC

This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 2P circuit breaker with 63A In rated current, a sensitivity of 30mA with a AC type protection class. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The mechanical endurance is going up to 20000 cycles and electrical endurance going up to 15000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.

Introduction Schneider A9R41263 is a cutting-edge Acti 9 iID Residual Current Circuit Breaker (RCCB) designed to ensure electrical safety in various applications. It incorporates advanced features and functionalities to provide reliable protection against electrical faults.

Features

  • Type: RCCB
  • Amperage: 63A
  • Sensitivity: 30mA
  • Type AC: Suitable for alternating current circuits

Functionality The Schneider A9R41263 RCCB operates by detecting any imbalance between the phase and neutral currents, thus indicating leakage or fault currents. It effectively disconnects the circuit upon detection, preventing potential electrical hazards and ensuring the safety of individuals and equipment.

Installation Installing the A9R41263 requires adherence to specific guidelines and safety measures. It should be done by qualified professionals following standard electrical installation practices to guarantee optimal performance and safety.

Applications This RCCB is suitable for a wide range of applications, including residential and industrial environments. Its versatility and high performance make it an ideal choice for ensuring electrical safety in various settings.

Benefits

  • Safety: Provides protection against electrical faults and leakage currents.
  • Efficiency: Helps in maintaining uninterrupted electrical supply by timely disconnection during faults, reducing downtime and potential damage.
  • Reliability: Built with quality materials and advanced technology, ensuring long-term reliability and performance.

Conclusion In summary, the Schneider A9R41263 Acti 9 iID RCCB is a reliable solution for electrical safety, offering advanced features, ease of installation, and versatile applications.

FAQs about Schneider A9R41263

  1. What does RCCB stand for?
    • RCCB stands for Residual Current Circuit Breaker.
  2. What is the importance of sensitivity in an RCCB?
    • Sensitivity, like 30mA in this model, determines the level of leakage current at which the RCCB will trip, providing crucial protection against electrical shocks.
  3. Can the A9R41263 be used in both residential and industrial settings?
    • Yes, it is designed for both residential and industrial applications, ensuring safety in diverse environments.
  4. How does the A9R41263 contribute to electrical efficiency?
    • By promptly disconnecting the circuit upon detecting faults, it prevents prolonged electrical supply interruptions and potential damage, enhancing overall efficiency.
  5. What are some safety measures to consider during the installation of the A9R41263?
    • Safety measures include proper grounding, following manufacturer guidelines, and ensuring insulation integrity to avoid electrical hazards during installation.
SKU: A9R41263 Category:
Main
Range Acti9
Product name Acti9 iID
Product or component type Residual current circuit breaker (RCCB)
Device short name iID
Poles description 2P
Neutral position Left
[In] rated current 63 A
Network type AC
Earth-leakage sensitivity 30 mA
earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type AC
Complementary
device location in system Outgoer
Network frequency 50/60 Hz
[Ue] rated operational voltage 220…240 V AC 50/60 Hz
Residual current tripping technology Voltage independent
Rated breaking and making capacity Idm 1500 A
Im 1500 A
Rated conditional short-circuit current 10 kA
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV
Surge current 250 A
Contact position indicator Yes
control type Toggle
Mounting mode Clip-on
mounting support DIN rail
9 mm pitches 4
height 91 mm
Width 36 mm
Depth 73.5 mm
Net weight 0.21 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability AC-1: 15000 cycles
Locking options description Padlocking device
Connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 14 mm for top or bottom connection
Tightening torque 3.5 N.m top or bottom
Environment
Standards EN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree 3
Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation -5…60 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.0 cm
Package 1 Width 4.0 cm
Package 1 Length 9.6 cm
Package 1 Weight 219 g
Unit Type of Package 2 S03
Number of Units in Package 2 54
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 12.267 kg
Unit Type of Package 3 P12
Number of Units in Package 3 432
Package 3 Height 44.4 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 110.136 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9R41263 | Acti 9 iID – RCCB – 2P – 63A – 30mA – type AC”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024