-28%
, , , ,

Schneider A9R44263 | Acti 9 iID – RCCB – 2P – 63A – 300mA – type AC

Schneider Electric
Availability:

In stock


Schneider A9R44263 | Acti 9 iID – RCCB – 2P – 63A – 300mA – type AC

 

3,345.70 EGP 4,645.70 EGP

In stock

Schneider A9R44263 | Acti 9 iID – RCCB – 2P – 63A – 300mA – type AC

Technical Specifications A9R44263

  • Product Code: A9R44263

  • Product Range: Acti 9 iID

  • Device Type: Residual Current Circuit Breaker (RCCB)

  • Number of Poles: 2 (Single-phase or Two-phase)

  • Rated Current (In): 63 A

  • Rated Residual Operating Current (IΔn): 300 mA

  • Type: Type AC (detects sinusoidal alternating residual currents only)

  • Rated Voltage: 230V AC (single-phase)

  • Rated Frequency: 50/60 Hz

  • Tripping Characteristic: Instantaneous

  • Mounting Type: DIN rail

  • Degree of Protection: IP20 (protection against accidental contact)

  • Standards Compliance: IEC 61008-1

  • Test Button: Yes (for manual testing)

  • Mechanical Durability: > 5000 operations

  • Electrical Durability: > 2000 operations at rated load

Key Features

  • 63A Rated Current: Suitable for low- to medium-power circuits requiring protection against earth leakage currents.

  • 300mA Sensitivity: Designed for fire prevention, this RCCB detects residual currents that could cause overheating or other risks associated with prolonged leakage currents, especially in systems where human safety is less of a concern than fire protection.

  • Type AC Detection: Specifically designed to detect sinusoidal AC leakage currents that are typically found in general residential and commercial systems.

  • Instantaneous Tripping: Instantly trips when the leakage current exceeds the rated threshold, ensuring rapid disconnection to avoid potential fire hazards.

  • Test Button: Allows for regular manual testing of the RCCB to ensure its functionality.

  • Compact and Modular Design: Space-saving and easy to install on DIN rails, making it an ideal choice for distribution panels.

  • Compliance with IEC Standards: Meets the IEC 61008-1 standard for electrical safety and reliability.

Applications

The A9R44263 RCCB is ideal for use in applications where the primary concern is fire protection due to residual current leakage. Its 300mA sensitivity makes it suitable for:

Residential Installations

  • Protection for household appliances and lighting systems, where fire prevention is the key concern due to extended leakage currents over time.

Commercial Installations

  • Suitable for retail spaces, offices, and small commercial buildings, providing safety for electrical systems in areas where personnel are less likely to come into direct contact with live conductors.

Industrial Environments

  • Ideal for protecting circuits in workshops, warehouses, and other industrial facilities that use three-phase or two-phase systems.

Electrical Distribution Panels

  • Provides residual current protection in main electrical panels where extended leakage currents may be a concern, especially for older systems or systems with deteriorating insulation.

Main
Range Acti9
Product name Acti9 iID
Product or component type Residual current circuit breaker (RCCB)
Device short name iID
Poles description 2P
Neutral position Left
[In] rated current 63 A
Network type AC
Earth-leakage sensitivity 300 mA
earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type AC
Complementary
device location in system Outgoer
Network frequency 50/60 Hz
[Ue] rated operational voltage 220…240 V AC 50/60 Hz
Residual current tripping technology Voltage independent
Rated breaking and making capacity Idm 1500 A
Im 1500 A
Rated conditional short-circuit current 10 kA
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV
Surge current 250 A
Contact position indicator Yes
control type Toggle
Mounting mode Clip-on
mounting support DIN rail
9 mm pitches 4
height 91 mm
Width 36 mm
Depth 73.5 mm
Net weight 0.21 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability AC-1: 15000 cycles
Locking options description Padlocking device
Connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 14 mm for top or bottom connection
Tightening torque 3.5 N.m top or bottom
Environment
Standards EN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree 3
Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation -5…60 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.000 cm
Package 1 Width 8.000 cm
Package 1 Length 10.000 cm
Package 1 Weight 211.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 6
Package 2 Height 9.000 cm
Package 2 Width 10.500 cm
Package 2 Length 25.000 cm
Package 2 Weight 1.332 kg
Unit Type of Package 3 S03
Number of Units in Package 3 54
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 12.375 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9R44263 | Acti 9 iID – RCCB – 2P – 63A – 300mA – type AC”

There are no reviews yet.

SHOPPING CART

close
Let's Chat