Schneider A9V44263 |Vigi iC60 – earth leakage add-on block – 2P – 63A – 300mA – AC type

Schneider Electric
Availability:

In stock


Schneider A9V44263 |Vigi iC60 – earth leakage add-on block – 2P – 63A – 300mA – AC type

3,173.80 EGP 4,845.50 EGP

In stock

Schneider A9V44263 | Vigi iC60 – earth leakage add-on block – 2P – 63A – 300mA – AC type

Technical Specifications A9V44263

  • Product Code: A9V44263

  • Product Range: Vigi iC60

  • Device Type: Earth Leakage Add-on Block

  • Number of Poles: 2 (for single-phase or two-phase systems)

  • Rated Current (In): 63 A

  • Rated Residual Operating Current (IΔn): 300 mA

  • Type: Type AC (detects sinusoidal alternating residual currents)

  • Rated Voltage: 230V AC

  • Rated Frequency: 50/60 Hz

  • Tripping Characteristic: Instantaneous

  • Mounting Type: Mounts directly on iC60 circuit breakers

  • Degree of Protection: IP20 (protection against accidental contact)

  • Standards Compliance: IEC 61008-1, IEC 60947-2

  • Test Button: Yes (for manual testing)

  • Mechanical Durability: > 5000 operations

  • Electrical Durability: > 2000 operations at rated load

Key Features

  • 63A Rated Current: The A9V44263 add-on block is designed for 63A circuits, making it suitable for medium-power systems, commonly found in residential, commercial, and some industrial environments.

  • 300mA Sensitivity: With a 300mA residual current sensitivity, this add-on block is ideal for applications where higher leakage current tolerance is necessary, such as industrial machinery or large appliances.

  • Type AC Detection: Designed to detect sinusoidal alternating currents, making it effective in AC electrical systems commonly found in most installations.

  • Instantaneous Tripping: The device provides immediate disconnection when leakage current exceeds the set threshold, minimizing the risk of electrical hazards.

  • 2-Pole Configuration: The 2-pole design is suitable for single-phase or two-phase systems, providing essential protection for those installations.

  • Easy Integration: The add-on block integrates seamlessly with iC60 circuit breakers, making it easy to upgrade existing electrical systems to include earth leakage protection.

  • Test Button: The test button allows users to check the functionality of the device and ensure that it will disconnect the circuit if leakage currents exceed the threshold.

  • Compact Design: The add-on block is compact and mounts on a DIN rail, optimizing space within electrical panels.

Applications

The Schneider A9V44263 is ideal for various residential, commercial, and industrial applications, particularly where higher leakage currents might be expected or allowed. Key applications include:

Residential Installations

  • Offers essential earth leakage protection for home electrical circuits, ensuring safety from electrical shock risks and fire hazards, especially in kitchens, bathrooms, or wet areas.

Commercial Installations

  • Suitable for shops, offices, and small businesses, where the risk of leakage currents exists but high sensitivity is not necessary. This add-on block is an effective choice for general commercial electrical systems.

Industrial Installations

  • The 300mA sensitivity makes this add-on block ideal for industrial settings where larger leakage currents are common, such as with heavy machinery, power tools, or large equipment.

Electrical Distribution Panels

  • Ideal for use in distribution boards or control panels that need to incorporate residual current protection in single-phase or two-phase systems.

Main
Range Acti9
Product or component type Add-on residual current devices
Device short name Vigi iC60
Poles description 2P
[In] rated current 63 A
Earth-leakage sensitivity 300 mA
earth-leakage protection time delay Instantaneous
Earth leakage protection type Type AC
Network type AC
Network frequency 50/60 Hz
[Ue] rated operational voltage 230/400 V AC 50/60 Hz conforming to EN 61009-1
230/415 V AC 50/60 Hz conforming to IEC 61009-1
conforming to IEC/EN 61009-2-1
Standards EN 61009-1
IEC 61009-1
9 mm pitches 4
Complementary
device location in system Outgoer
Residual current tripping technology Voltage independent
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Range compatibility Acti 9 Acti9 iC60
Acti 9 Acti9 Reflex iC60
Product compatibility Single terminal
local signalling Trip indicator
Mounting mode Clip-on
mounting support DIN rail
Electrical connection to mcb By screws
Comb busbar and distribution block compatibility Bottom: YES
height 91 mm
Width 72 mm
Depth 73.5 mm
Net weight 0.165 kg
Connections – terminals Tunnel type terminal downside for 1 cable(s) 1…35 mm² rigid without cable end
Tunnel type terminal downside for 1 cable(s) 1…25 mm² flexible without cable end
Tunnel type terminal downside for 1 cable(s) 1…25 mm² flexible with cable end
Wire stripping length 14 mm for bottom connection
Tightening torque 3.5 N.m bottom
Environment
IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree 3 conforming to IEC 60947-2
Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to IEC 61009-1
ambient air temperature for operation -5…60 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.6 cm
Package 1 Width 8.6 cm
Package 1 Length 12.2 cm
Package 1 Weight 160.0 g
Unit Type of Package 2 S03
Number of Units in Package 2 27
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 4.81 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews