Schneider ATS480C11Y| Soft starter, Altistart 480, 110A, 208 to 690V AC, control supply 110 to 230V AC

Schneider ATS480C11Y | Soft Starter Overview

The Schneider ATS480C11Y is a soft starter from the Altistart 480 series, designed for smooth motor acceleration and deceleration, reducing mechanical stress and electrical surges. With a rated current of 110A, it is ideal for various industrial applications requiring reliable motor control and protection.

1. General Specifications

  • Product Name: Schneider ATS480C11Y

  • Series: Altistart 480

  • Function: Soft Starter

  • Rated Current: 110A

  • Operating Voltage: 208V to 690V AC

  • Control Supply Voltage: 110V to 230V AC

2. Key Features & Benefits

Soft Start & Stop: Reduces mechanical stress and extends motor lifespan.
High Current Handling: Supports motors with a 110A rated current.
Wide Voltage Range: Operates within 208V to 690V AC, making it versatile for different industries.
Advanced Motor Protection: Includes overload, short circuit, and overheating protection.
User-Friendly Interface: Digital display with programmable settings for easy configuration.
Seamless Integration: Compatible with modern automation and industrial control systems.

3. Applications

🔹 Pumps & Compressors – Smooth startup prevents pressure surges and mechanical wear.
🔹 HVAC & Blowers – Enhances energy efficiency and reduces electrical spikes.
🔹 Conveyors & Material Handling – Ensures consistent motor operation and longevity.
🔹 Mining & Heavy Equipment – Provides stable motor control in demanding environments.
🔹 Water & Wastewater Treatment – Ideal for large-scale pumping systems requiring soft start features.

4. Protection & Safety Features

  • Overload Protection – Prevents excessive current draw, extending motor lifespan.

  • Short Circuit Protection – Ensures safe operation and system reliability.

  • Overtemperature Protection – Protects against overheating issues.

  • Phase Loss & Imbalance Detection – Maintains stable and efficient motor performance.

5. Installation & Maintenance

Quick & Easy Setup – Simplifies wiring and integration into control panels.
Real-Time Monitoring & Diagnostics – Supports preventive maintenance and fault detection.
Robust Industrial Design – Engineered to withstand harsh operating conditions.

Weight8.3 kg
brands

Main
Range of ProductAltivar Soft Starter ATS480
Product or Component TypeSoft starter
Product destinationAsynchronous motors
Product Specific ApplicationProcess and infrastructures
Device short nameATS480
Phase3 phase
Utilisation categoryAC-3A
AC-53A
Ue power supply voltage208…690 V – 15…10 %
power supply frequency50…60 Hz – 20…20 %
[Ie] rated operational currentNormal duty 110.0 A 104 °F (40 °C))
rated current in heavy duty88.0 A at 104 °F (40 °C) heavy duty
Torque controlTrue
IP Degree of ProtectionIP20
Motor power kW30.0 kW 230 V in the motor supply line normal duty
22.0 kW 230 V in the motor supply line heavy duty
55.0 kW 400 V in the motor supply line normal duty
45.0 kW 400 V in the motor supply line heavy duty
55.0 kW 440 V in the motor supply line normal duty
45.0 kW 440 V in the motor supply line heavy duty
75.0 kW 500 V in the motor supply line normal duty
55.0 kW 500 V in the motor supply line heavy duty
75.0 kW 525 V in the motor supply line normal duty
55.0 kW 525 V in the motor supply line heavy duty
90.0 kW 660 V in the motor supply line normal duty
75.0 kW 660 V in the motor supply line heavy duty
90.0 kW 690 V in the motor supply line normal duty
75.0 kW 690 V in the motor supply line heavy duty
55.0 kW 230 V to the motor delta terminals normal duty
45.0 kW 230 V to the motor delta terminals heavy duty
90.0 kW 400 V to the motor delta terminals normal duty
75.0 kW 400 V to the motor delta terminals heavy duty
Maximum Horse Power Rating30.0 hp 208 V normal duty
25.0 hp 208 V heavy duty
40.0 hp 230 V normal duty
30.0 hp 230 V heavy duty
75.0 hp 460 V normal duty
60.0 hp 460 V heavy duty
100.0 hp 575 V normal duty
75.0 hp 575 V heavy duty
Option cardCommunication module Profibus DP V1
Communication module Modbus TCP/EtherNet/IP
Communication module CANopen daisy chain
Communication module CANopen Sub-D
Communication module CANopen open style
Complementary
Device connectionIn the motor supply line
To the motor delta terminals
[Us] control circuit voltage110…230 V AC 50/60 Hz – 15…10 %
Apparent power0.09 kVA
Integrated motor overload protectionTrue
motor thermal protection classClass 10E
Protection typePhase failure line
Integrated thermal protection motor
Thermal protection starter
Current overload motor
Underload motor
Excessive starting time, locked rotor motor
Motor phase loss motor
Line supply phase loss line
Line supply phase loss motor
Thermal protection motor
current limiting %In (5 x Ie maximum)150…700 %
[In] Rated current pwr loss specifctn110.0 A
Power loss static current independent25.0 W
Power loss per device current dependent302.0 W
StandardsIEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Product CertificationsCE
cULus
CCC
UKCA
RCM
EAC
DNV
ABS
BV
CCS
MarkingCE
CCC
UKCA
EAC
RCM
CULus
[Uc] control circuit voltage24 V DC
Discrete input number4
Discrete input typeSTOP) logic inputs, 3500 Ohm
RUN) logic inputs, 3500 Ohm
DI3) programmable as logic input, 3500 Ohm
DI4) programmable as logic input, 3500 Ohm
Input compatibilitySTOP discrete input level 1 PLC IEC 61131-2
RUN discrete input level 1 PLC IEC 61131-2
DI3 discrete input level 1 PLC IEC 61131-2
DI4 discrete input level 1 PLC IEC 61131-2
Discrete input logicProgrammable digital input < 5 V
Relay output number3
Relay output typeRelay outputs R1A 1 NO
Relay outputs R1B 1 NO
Relay outputs RIC NO/NC programmable
Minimum switching current100 mA 12 V DC relay outputs
Maximum switching currentRelay outputs 2 A 250 V AC
Relay outputs 2 A 30 V DC
Relay outputs
Discrete output number2
Discrete output typeDQ1) programmable digital output <= 30 V
DQ2) programmable digital output <= 30 V
Output compatibilityOpen collector level 1 PLC IEC 65A-68
Analogue input number1
Analogue input typeAI1/PTC PTC/Pt 100 temperature probe
PTC2 PTC/Pt 100 temperature probe
PTC3 PTC/Pt 100 temperature probe
Analogue output number1
Analogue output typeCurrent output AQ1 0…20 mA or 0…10 V 500 Ohm
Communication Port ProtocolModbus serial
Connector Type1 RJ45
Communication data linkSerial
Physical interface2-wire RS 485
Transmission Rate1200…256000 bit/s
Transmission frameRTU
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance Modbus serial
Number of addresses0…227 Modbus serial
Method of accessSlave Modbus serial
Function AvailableExternal bypass control
Pre-heating
Smoke extraction
Multi-motor cascade
Second motor set
User management
Ports and services hardening
Security event logging
Cybersecure firmware update
Single direction
Display screen availableTrue
Operating positionVertical +/- 10 degree
Height11.4 in (290.0 mm)
Width7.5 in (190.0 mm)
Depth9.7 in (247.0 mm)
Net Weight18.3 lb(US) (8.3 kg)
Environment
Electromagnetic compatibilityConducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-11
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
pollution degreeLevel 3
[Uimp] rated impulse withstand voltage6 kV
[Ui] Rated Insulation Voltage690 V
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Relative humidity0…95 % without condensation or dripping water IEC 60068-2-3
Ambient air temperature for operation104…140 °F (40…60 °C) (with current derating of 2 % per °C)
5…104 °F (-15…40 °C) (without derating)
Ambient Air Temperature for Storage-13…158 °F (-25…70 °C)
Operating altitude<= 3280.84 ft (1000 m) without derating
> 3280.84…13123.36 ft (> 1000…4000 m) with current derating 1 % per 100 m
Maximum deflection under vibratory load (during operation)1.5 mm at 2…13 Hz
Maximum deflection under vibratory load (during storage)1.75 mm at 2…9 Hz
Maximum deflection under vibratory load (during transport)1.75 mm at 2…9 Hz
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13…200 Hz
Maximum acceleration under vibratory load (during storage)15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under vibratory load (during transport)15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under shock load (during storage)100 m/s² at 11 ms
Maximum acceleration under shock load (during transport)100 m/s² at 11 ms
Ordering and shipping details
CategoryUS1CP1G22588
Discount ScheduleCP1G
GTIN3606481089076
ReturnabilityYes
Country of originID
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.57 in (37.000 cm)
Package 1 Width12.20 in (31.000 cm)
Package 1 Length15.35 in (39.000 cm)
Package 1 Weight21.775 lb(US) (9.877 kg)
Unit Type of Package 2P06
Number of Units in Package 28
Package 2 Height33.86 in (86.000 cm)
Package 2 Width23.62 in (60.000 cm)
Package 2 Length31.50 in (80.000 cm)
Package 2 Weight192.905 lb(US) (87.500 kg)

Main documents

DatasheetDownload Datasheet
Product datasheetDownload
User guide
Download
Instruction sheet
Download
Catalogue
Download
CAD FilesDownload
Environmental disclosure
Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider ATS480C11Y | Soft starter, Altistart 480, 110A, 208 to 690V AC, control supply 110 to 230V AC”

There are no reviews yet.

SHOPPING CART

close
Let's Chat