Schneider ATS480C17Y| Soft starter, Altistart 480, 170A, 208 to 690V AC, control supply 110 to 230V AC

Schneider ATS480C17Y | Soft Starter Overview

The Schneider ATS480C17Y is a soft starter from the Altistart 480 series, designed to ensure smooth motor acceleration and deceleration while minimizing mechanical and electrical stress. With a rated current of 170A, this model is ideal for industrial applications that require controlled motor startup and protection.

1. General Specifications

  • Product Name: Schneider ATS480C17Y

  • Series: Altistart 480

  • Function: Soft Starter

  • Rated Current: 170A

  • Operating Voltage: 208V to 690V AC

  • Control Supply Voltage: 110V to 230V AC

2. Key Features & Benefits

Soft Start & Stop: Reduces mechanical and electrical stress on motors.
High Current Capacity: Supports motors requiring up to 170A.
Wide Voltage Range: Operates within 208V to 690V AC, suitable for global applications.
Advanced Motor Protection: Protects against overload, overheating, and short circuits.
User-Friendly Interface: Features digital display and programmable settings for easy operation.
Seamless Integration: Compatible with modern industrial automation systems.

3. Applications

🔹 Pumps & Compressors – Prevents pressure surges and extends equipment life.
🔹 HVAC & Blower Systems – Enhances efficiency by reducing energy spikes.
🔹 Conveyors & Material Handling – Ensures smooth start-up, reducing mechanical wear.
🔹 Mining & Heavy Machinery – Provides stable motor control in demanding conditions.
🔹 Water & Wastewater Treatment – Ensures efficient operation in large pumping systems.

4. Protection & Safety Features

  • Overload Protection – Prevents excessive current draw and extends motor lifespan.

  • Short Circuit Protection – Enhances reliability and prevents electrical faults.

  • Overtemperature Protection – Regulates internal temperature for safe operation.

  • Phase Loss & Imbalance Detection – Ensures stable and efficient motor performance.

5. Installation & Maintenance

Easy Wiring & Setup – Quick integration into electrical control panels.
Real-Time Monitoring & Diagnostics – Helps in preventive maintenance and fault detection.
Durable Industrial Design – Built to withstand harsh environments.

Weight 12.4 kg
brands

Main
Range of Product Altivar Soft Starter ATS480
Product or Component Type Soft starter
Product destination Asynchronous motors
Product Specific Application Process and infrastructures
Device short name ATS480
Phase 3 phase
Utilisation category AC-3A
AC-53A
Ue power supply voltage 208…690 V – 15…10 %
power supply frequency 50…60 Hz – 20…20 %
[Ie] rated operational current Normal duty 170.0 A 104 °F (40 °C))
rated current in heavy duty 140.0 A at 104 °F (40 °C) heavy duty
Torque control True
IP Degree of Protection IP00
Motor power kW 45.0 kW 230 V in the motor supply line normal duty
37.0 kW 230 V in the motor supply line heavy duty
90.0 kW 400 V in the motor supply line normal duty
75.0 kW 400 V in the motor supply line heavy duty
90.0 kW 440 V in the motor supply line normal duty
75.0 kW 440 V in the motor supply line heavy duty
110.0 kW 500 V in the motor supply line normal duty
90.0 kW 500 V in the motor supply line heavy duty
110.0 kW 525 V in the motor supply line normal duty
90.0 kW 525 V in the motor supply line heavy duty
132.0 kW 660 V in the motor supply line normal duty
110.0 kW 660 V in the motor supply line heavy duty
160.0 kW 690 V in the motor supply line normal duty
110.0 kW 690 V in the motor supply line heavy duty
90.0 kW 230 V to the motor delta terminals normal duty
75.0 kW 230 V to the motor delta terminals heavy duty
132.0 kW 400 V to the motor delta terminals normal duty
110.0 kW 400 V to the motor delta terminals heavy duty
Maximum Horse Power Rating 50.0 hp 208 V normal duty
40.0 hp 208 V heavy duty
60.0 hp 230 V normal duty
50.0 hp 230 V heavy duty
125.0 hp 460 V normal duty
100.0 hp 460 V heavy duty
150.0 hp 575 V normal duty
125.0 hp 575 V heavy duty
Option card Communication module Profibus DP V1
Communication module Modbus TCP/EtherNet/IP
Communication module CANopen daisy chain
Communication module CANopen Sub-D
Communication module CANopen open style
Complementary
Device connection In the motor supply line
To the motor delta terminals
[Us] control circuit voltage 110…230 V AC 50/60 Hz – 15…10 %
Apparent power 0.09 kVA
Integrated motor overload protection True
motor thermal protection class Class 10E
Protection type Phase failure line
Integrated thermal protection motor
Thermal protection starter
Current overload motor
Underload motor
Excessive starting time, locked rotor motor
Motor phase loss motor
Line supply phase loss line
Line supply phase loss motor
Thermal protection motor
current limiting %In (5 x Ie maximum) 150…700 %
[In] Rated current pwr loss specifctn 170.0 A
Power loss static current independent 25.0 W
Power loss per device current dependent 459.0 W
Standards IEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Product Certifications CE
cULus
CCC
UKCA
RCM
EAC
DNV
ABS
BV
CCS
Marking CE
CCC
UKCA
EAC
RCM
CULus
[Uc] control circuit voltage 24 V DC
Discrete input number 4
Discrete input type STOP) logic inputs, 3500 Ohm
RUN) logic inputs, 3500 Ohm
DI3) programmable as logic input, 3500 Ohm
DI4) programmable as logic input, 3500 Ohm
Input compatibility STOP discrete input level 1 PLC IEC 61131-2
RUN discrete input level 1 PLC IEC 61131-2
DI3 discrete input level 1 PLC IEC 61131-2
DI4 discrete input level 1 PLC IEC 61131-2
Discrete input logic Programmable digital input < 5 V
Relay output number 3
Relay output type Relay outputs R1A 1 NO
Relay outputs R1B 1 NO
Relay outputs RIC NO/NC programmable
Minimum switching current 100 mA 12 V DC relay outputs
Maximum switching current Relay outputs 2 A 250 V AC
Relay outputs 2 A 30 V DC
Relay outputs
Discrete output number 2
Discrete output type DQ1) programmable digital output <= 30 V
DQ2) programmable digital output <= 30 V
Output compatibility Open collector level 1 PLC IEC 65A-68
Analogue input number 1
Analogue input type AI1/PTC PTC/Pt 100 temperature probe
PTC2 PTC/Pt 100 temperature probe
PTC3 PTC/Pt 100 temperature probe
Analogue output number 1
Analogue output type Current output AQ1 0…20 mA or 0…10 V 500 Ohm
Communication Port Protocol Modbus serial
Connector Type 1 RJ45
Communication data link Serial
Physical interface 2-wire RS 485
Transmission Rate 1200…256000 bit/s
Transmission frame RTU
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance Modbus serial
Number of addresses 0…227 Modbus serial
Method of access Slave Modbus serial
Function Available External bypass control
Pre-heating
Smoke extraction
Multi-motor cascade
Second motor set
User management
Ports and services hardening
Security event logging
Cybersecure firmware update
Single direction
Display screen available True
Operating position Vertical +/- 10 degree
Height 13.4 in (340.0 mm)
Width 7.9 in (200.0 mm)
Depth 10.7 in (272.0 mm)
Net Weight 27.3 lb(US) (12.4 kg)
Environment
Electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-11
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
pollution degree Level 3
[Uimp] rated impulse withstand voltage 6 kV
[Ui] Rated Insulation Voltage 690 V
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Relative humidity 0…95 % without condensation or dripping water IEC 60068-2-3
Ambient air temperature for operation 104…140 °F (40…60 °C) (with current derating of 2 % per °C)
5…104 °F (-15…40 °C) (without derating)
Ambient Air Temperature for Storage -13…158 °F (-25…70 °C)
Operating altitude <= 3280.84 ft (1000 m) without derating
> 3280.84…13123.36 ft (> 1000…4000 m) with current derating 1 % per 100 m
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz
Maximum deflection under vibratory load (during storage) 1.75 mm at 2…9 Hz
Maximum deflection under vibratory load (during transport) 1.75 mm at 2…9 Hz
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13…200 Hz
Maximum acceleration under vibratory load (during storage) 15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under vibratory load (during transport) 15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under shock load (during storage) 100 m/s² at 11 ms
Maximum acceleration under shock load (during transport) 100 m/s² at 11 ms
Ordering and shipping details
Category US1CP1G22588
Discount Schedule CP1G
GTIN 3606481089090
Returnability Yes
Country of origin ID
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 16.93 in (43.0 cm)
Package 1 Width 12.60 in (32.0 cm)
Package 1 Length 17.91 in (45.5 cm)
Package 1 Weight 31.674 lb(US) (14.367 kg)
Unit Type of Package 2 S06
Number of Units in Package 2 2
Package 2 Height 29.53 in (75.0 cm)
Package 2 Width 23.62 in (60.0 cm)
Package 2 Length 31.50 in (80.0 cm)
Package 2 Weight 92.2 lb(US) (41.8 kg)

Based on 0 reviews

0.0 overall
0
0
0
0
0