-42%

Schneider ATS480C48Y | Soft starter, Altistart 480, 480A, 208 to 690V AC, control supply 110 to 230V AC

Schneider Electric
Availability:

Out of stock


335,618.50 EGP 578,652.60 EGP

Out of stock

Schneider ATS480C48Y | Soft starter, Altistart 480, 480A, 208 to 690V AC, control supply 110 to 230V AC

Schneider ATS480C48Y | Soft Starter Overview

The Schneider ATS480C48Y is a soft starter from the Altistart 480 series, designed to ensure smooth motor acceleration and deceleration while protecting against electrical and mechanical stress. With a rated current of 480A, this model is well-suited for industrial applications requiring efficient motor control, safety, and automation compatibility.

1. General Specifications

  • Product Name: Schneider ATS480C48Y

  • Series: Altistart 480

  • Function: Soft Starter

  • Rated Current: 480A

  • Operating Voltage: 208V to 690V AC

  • Control Supply Voltage: 110V to 230V AC

2. Key Features & Benefits

Smooth Start & Stop: Reduces mechanical wear and prevents sudden electrical surges.
High Current Handling: Suitable for motors requiring up to 480A of current.
Wide Voltage Range: Operates efficiently within 208V to 690V AC.
Advanced Motor Protection: Protects against overload, short circuits, and overheating.
User-Friendly Interface: Equipped with a digital display and programmable settings.
Seamless Automation Integration: Compatible with modern industrial control systems.

3. Applications

🔹 Pumps & Compressors – Prevents sudden pressure surges and ensures energy efficiency.
🔹 HVAC & Blower Systems – Provides stable startup and protects mechanical components.
🔹 Conveyors & Material Handling – Enhances durability by reducing mechanical stress.
🔹 Mining & Heavy Machinery – Ensures controlled motor performance for high-power applications.
🔹 Water & Wastewater Treatment – Supports large pumping systems for efficient operation.

4. Protection & Safety Features

  • Overload Protection – Prevents excessive current draw, ensuring motor longevity.

  • Short Circuit Protection – Enhances reliability and prevents electrical damage.

  • Overtemperature Protection – Maintains safe operating temperatures for durability.

  • Phase Loss & Imbalance Detection – Ensures stable and efficient motor performance.

5. Installation & Maintenance

Simple Wiring & Setup – Designed for quick installation in electrical panels.
Real-Time Monitoring & Diagnostics – Supports preventive maintenance and fault detection.
Durable Industrial Design – Engineered to withstand harsh working environments.

Weight 51.4 kg
brands

Main
Range of Product Altivar Soft Starter ATS480
Product or Component Type Soft starter
Product destination Asynchronous motors
Product Specific Application Process and infrastructures
Device short name ATS480
Phase 3 phase
Utilisation category AC-3A
AC-53A
Ue power supply voltage 208…690 V – 15…10 %
power supply frequency 50…60 Hz – 20…20 %
[Ie] rated operational current Normal duty 480.0 A 104 °F (40 °C))
rated current in heavy duty 410.0 A at 104 °F (40 °C) heavy duty
Torque control True
IP Degree of Protection IP00
Motor power kW 132.0 kW 230 V in the motor supply line normal duty
110.0 kW 230 V in the motor supply line heavy duty
250.0 kW 400 V in the motor supply line normal duty
220.0 kW 400 V in the motor supply line heavy duty
250.0 kW 440 V in the motor supply line normal duty
220.0 kW 440 V in the motor supply line heavy duty
315.0 kW 500 V in the motor supply line normal duty
250.0 kW 500 V in the motor supply line heavy duty
315.0 kW 525 V in the motor supply line normal duty
250.0 kW 525 V in the motor supply line heavy duty
400.0 kW 660 V in the motor supply line normal duty
355.0 kW 660 V in the motor supply line heavy duty
500.0 kW 690 V in the motor supply line normal duty
400.0 kW 690 V in the motor supply line heavy duty
250.0 kW 230 V to the motor delta terminals normal duty
220.0 kW 230 V to the motor delta terminals heavy duty
355.0 kW 400 V to the motor delta terminals normal duty
315.0 kW 400 V to the motor delta terminals heavy duty
Maximum Horse Power Rating 150.0 hp 208 V normal duty
125.0 hp 208 V heavy duty
150.0 hp 230 V heavy duty
350.0 hp 460 V normal duty
300.0 hp 460 V heavy duty
400.0 hp 575 V normal duty
350.0 hp 575 V heavy duty
Option card Communication module Profibus DP V1
Communication module Modbus TCP/EtherNet/IP
Communication module CANopen daisy chain
Communication module CANopen Sub-D
Communication module CANopen open style
Complementary
Device connection In the motor supply line
To the motor delta terminals
[Us] control circuit voltage 110…230 V AC 50/60 Hz – 15…10 %
Apparent power 0.125 kVA
Integrated motor overload protection True
motor thermal protection class Class 10E
Protection type Phase failure line
Integrated thermal protection motor
Thermal protection starter
Current overload motor
Underload motor
Excessive starting time, locked rotor motor
Motor phase loss motor
Line supply phase loss line
Line supply phase loss motor
Thermal protection motor
current limiting %In (5 x Ie maximum) 150…700 %
[In] Rated current pwr loss specifctn 480.0 A
Power loss static current independent 25.0 W
Power loss per device current dependent 1366.0 W
Standards IEC 60947-4-2
UL 60947-4-2
IEC 60664-1
Product Certifications CE
cULus
CCC
UKCA
RCM
EAC
DNV
ABS
BV
CCS
Marking CE
CCC
UKCA
EAC
RCM
CULus
[Uc] control circuit voltage 24 V DC
Discrete input number 4
Discrete input type STOP) logic inputs, 3500 Ohm
RUN) logic inputs, 3500 Ohm
DI3) programmable as logic input, 3500 Ohm
DI4) programmable as logic input, 3500 Ohm
Input compatibility STOP discrete input level 1 PLC IEC 61131-2
RUN discrete input level 1 PLC IEC 61131-2
DI3 discrete input level 1 PLC IEC 61131-2
DI4 discrete input level 1 PLC IEC 61131-2
Discrete input logic Programmable digital input < 5 V
Relay output number 3
Relay output type Relay outputs R1A 1 NO
Relay outputs R1B 1 NO
Relay outputs RIC NO/NC programmable
Minimum switching current 100 mA 12 V DC relay outputs
Maximum switching current Relay outputs 2 A 250 V AC
Relay outputs 2 A 30 V DC
Relay outputs
Discrete output number 2
Discrete output type DQ1) programmable digital output <= 30 V
DQ2) programmable digital output <= 30 V
Output compatibility Open collector level 1 PLC IEC 65A-68
Analogue input number 1
Analogue input type AI1/PTC PTC/Pt 100 temperature probe
PTC2 PTC/Pt 100 temperature probe
PTC3 PTC/Pt 100 temperature probe
Analogue output number 1
Analogue output type Current output AQ1 0…20 mA or 0…10 V 500 Ohm
Communication Port Protocol Modbus serial
Connector Type 1 RJ45
Communication data link Serial
Physical interface 2-wire RS 485
Transmission Rate 1200…256000 bit/s
Transmission frame RTU
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance Modbus serial
Number of addresses 0…227 Modbus serial
Method of access Slave Modbus serial
Function Available External bypass control
Pre-heating
Smoke extraction
Multi-motor cascade
Second motor set
User management
Ports and services hardening
Security event logging
Cybersecure firmware update
Single direction
Display screen available True
Operating position Vertical +/- 10 degree
Height 26.4 in (670.0 mm)
Width 15.7 in (400.0 mm)
Depth 12.4 in (314.0 mm)
Net Weight 113.3 lb(US) (51.4 kg)
Environment
Electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-11
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
pollution degree Level 3
[Uimp] rated impulse withstand voltage 6 kV
[Ui] Rated Insulation Voltage 690 V
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Relative humidity 0…95 % without condensation or dripping water IEC 60068-2-3
Ambient air temperature for operation 104…140 °F (40…60 °C) (with current derating of 2 % per °C)
5…104 °F (-15…40 °C) (without derating)
Ambient Air Temperature for Storage -13…158 °F (-25…70 °C)
Operating altitude <= 3280.84 ft (1000 m) without derating
> 3280.84…13123.36 ft (> 1000…4000 m) with current derating 1 % per 100 m
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz
Maximum deflection under vibratory load (during storage) 1.75 mm at 2…9 Hz
Maximum deflection under vibratory load (during transport) 1.75 mm at 2…9 Hz
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13…200 Hz
Maximum acceleration under vibratory load (during storage) 15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under vibratory load (during transport) 15 m/s² at 200…500 Hz
10 m/s² at 9…200 Hz
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under shock load (during storage) 100 m/s² at 11 ms
Maximum acceleration under shock load (during transport) 100 m/s² at 11 ms
Ordering and shipping details
Category US1CP1G22588
Discount Schedule CP1G
GTIN 3606481089144
Returnability Yes
Country of origin SG
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 21.65 in (55.000 cm)
Package 1 Width 20.87 in (53.000 cm)
Package 1 Length 31.50 in (80.000 cm)
Package 1 Weight 134.482 lb(US) (61.000 kg)

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider ATS480C48Y | Soft starter, Altistart 480, 480A, 208 to 690V AC, control supply 110 to 230V AC”