Schneider ATV12H037M3: The Ultimate Guide

Introduction

When it comes to efficient motor control in industrial applications, the Schneider ATV12H037M3 stands out as a reliable and advanced solution. Understanding its features, benefits, and applications can significantly enhance your operational efficiency. This article aims to provide an in-depth look at the Schneider ATV12H037M3, from its key specifications to practical tips for installation and use.

Understanding the Schneider ATV12H037M3

What is the Schneider ATV12H037M3?

The Schneider ATV12H037M3 is a variable frequency drive (VFD) designed for small machines and simple applications. It provides precise motor control, enhancing the performance and efficiency of your machinery.

Key Features and Specifications

  • Power Rating: 0.37 kW (0.5 HP)
  • Input Voltage: 200-240V, 3-phase
  • Output Frequency: 0.5 to 400 Hz
  • Control Type: Scalar control (V/Hz)
  • Protection: IP20 enclosure, overcurrent, overvoltage, and thermal protection

Benefits of Using the Schneider ATV12H037M3

  • Energy Efficiency: Reduces energy consumption by optimizing motor speed.
  • Ease of Use: User-friendly interface and simple configuration.
  • Reliability: Robust design ensures long-term performance.
  • Versatility: Suitable for a wide range of applications.

Applications of the Schneider ATV12H037M3

Common Industries and Use Cases

The Schneider ATV12H037M3 is commonly used in:

  • HVAC Systems: Ensuring optimal performance and energy efficiency.
  • Pumps and Fans: Controlling speed for better process management.
  • Conveyors: Improving operational efficiency in manufacturing.

Real-World Examples of Implementation

  • Manufacturing Plants: Enhancing production line efficiency.
  • Water Treatment Facilities: Optimizing pump operation to conserve energy.
  • Agricultural Operations: Controlling irrigation systems for better crop management.

Advantages in Specific Applications

  • Precision Control: Achieving desired performance in various processes.
  • Cost Savings: Lowering energy bills and maintenance costs.
  • Improved Durability: Extending the lifespan of your equipment.

Installation and Setup

Pre-installation Considerations

  • Verify Electrical Specifications: Ensure compatibility with your power supply.
  • Check Environmental Conditions: Install in a clean, dry, and well-ventilated area.

Step-by-Step Installation Guide

  1. Mount the VFD: Securely mount the Schneider ATV12H037M3 on a stable surface.
  2. Connect the Power Supply: Follow the wiring diagram to connect to the power source.
  3. Wire the Motor: Connect the motor terminals to the VFD outputs.
  4. Configure the Settings: Use the interface to set initial parameters.

Initial Setup and Configuration

  • Parameter Setting: Configure parameters like motor voltage, current, and frequency.
  • Test Run: Perform a test run to ensure proper operation.

Operating the Schneider ATV12H037M3

Basic Operation Principles

  • Start/Stop Control: Use the interface to start and stop the motor.
  • Speed Adjustment: Adjust motor speed using the control panel.

User Interface and Controls

  • LCD Display: Provides real-time data on motor performance.
  • Keypad: Allows for easy parameter adjustments.

Tips for Efficient Operation

  • Regular Monitoring: Keep an eye on performance metrics.
  • Optimal Settings: Fine-tune settings for your specific application.

Maintenance and Troubleshooting

Regular Maintenance Practices

  • Routine Inspections: Check for dust buildup and clean regularly.
  • Firmware Updates: Ensure the VFD firmware is up-to-date.

Common Issues and Their Solutions

  • Overheating: Ensure proper ventilation and reduce load if necessary.
  • Unexpected Shutdowns: Check for electrical faults or parameter errors.

When to Seek Professional Help

  • Complex Issues: If troubleshooting doesn’t resolve the problem, consult a professional.
  • Major Repairs: For significant damage, professional repair is recommended.

Advanced Features and Customization

Overview of Advanced Functionalities

  • Programmable Logic: Customize operations with built-in programming options.
  • Remote Monitoring: Integrate with supervisory systems for remote monitoring.

Customization Options

  • User-defined Parameters: Tailor settings to your specific needs.
  • Interface Options: Choose between different user interfaces for control.

Integrating with Other Systems

  • Communication Protocols: Supports Modbus and other protocols for seamless integration.
  • Automation Systems: Compatible with various automation and control systems.

Energy Efficiency and Cost Savings

How the ATV12H037M3 Enhances Energy Efficiency

  • Variable Speed Control: Matches motor speed to the actual load requirement.
  • Reduced Power Consumption: Lowers energy usage during low-demand periods.

Cost-saving Benefits

  • Lower Utility Bills: Reduced energy consumption translates to savings.
  • Extended Equipment Life: Proper motor control reduces wear and tear.

Environmental Impact

  • Reduced Carbon Footprint: Lower energy consumption helps in reducing greenhouse gas emissions.
  • Sustainable Operations: Supports your sustainability goals.
SKU: ATV12H037M3 Category:
Main
Range of product Altivar 12
Product or component type Variable speed drive
Product specific application Simple machine
mounting mode Cabinet mount
Communication port protocol Modbus
Supply frequency 50/60 Hz +/- 5 %
[Us] rated supply voltage 200…240 V – 15…10 %
Nominal output current 2.4 A
Motor power hp 0.55 hp
Motor power kW 0.37 kW
Motor power hp 0.55 hp
EMC filter Without EMC filter
IP degree of protection IP20
Complementary
Discrete input number 4
Discrete output number 2
Analogue input number 1
Analogue output number 1
Relay output number 1
Physical interface 2-wire RS 485
Connector type 1 RJ45
Continuous output current 2.4 A at 4 kHz
Method of access Server Modbus serial
Speed drive output frequency 0.5…400 Hz
Speed range 1…20
Sampling duration 20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue input
Linearity error +/- 0.3 % of maximum value for analogue input
Frequency resolution Analog input: converter A/D, 10 bits
Display unit: 0.1 Hz
Time constant 20 ms +/- 1 ms for reference change
Transmission rate 9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, configurable odd, even or no parity
Communication service Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
Type of polarization No impedance
4 quadrant operation possible False
Asynchronous motor control profile Quadratic voltage/frequency ratio
Voltage/frequency ratio (V/f)
Sensorless flux vector control
Maximum output frequency 4 kHz
Transient overtorque 150…170 % of nominal motor torque depending on drive rating and type of motor
Acceleration and deceleration ramps S
Linear from 0 to 999.9 s
U
Motor slip compensation Adjustable
Preset in factory
Switching frequency 2…16 kHz adjustable
4…16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated False
Line current 3.6 A at 100 V (heavy duty)
3.0 A at 120 V (heavy duty)
Maximum input current 3.0 A
Maximum output voltage 240 V
Apparent power 1.2 kVA at 240 V (heavy duty)
Maximum transient current 3.6 A during 60 s (heavy duty)
4.0 A during 2 s (heavy duty)
Network frequency 50…60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 5 kA
Base load current at high overload 2.4 A
Power dissipation in W Natural: 24.0 W
With safety function Safely Limited Speed (SLS) False
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) False
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) False
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
Tightening torque 0.8 N.m
Insulation Electrical between power and control
Quantity per set Set of 1
Width 72 mm
Height 143 mm
Depth 121.2 mm
Net weight 0.8 kg
Environment
Operating altitude <= 1000 m without derating
> 1000…3000 m with current derating 1 % per 100 m
Operating position Vertical +/- 10 degree
Product certifications NOM
CSA
C-Tick
UL
GOST
RCM
KC
Marking CE
Standards UL 508C
UL 618000-5-1
IEC 61800-5-1
IEC 61800-3
Assembly style With heat sink
Electromagnetic compatibility Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Surge immunity test level 3 conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13…200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz
Overvoltage category Class III
Regulation loop Adjustable PID regulator
Electromagnetic emission Radiated emissions environment 1 category C2 conforming to IEC 61800-3 2…16 kHz shielded motor cable
Conducted emissions with additional EMC filter environment 1 category C2 conforming to IEC 61800-3 4…12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 2 category C3 conforming to IEC 61800-3 4…12 kHz shielded motor cable <20 m
Vibration resistance 1 gn (f = 13…200 Hz) conforming to IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to IEC 60068-2-6
Shock resistance 15 gn conforming to IEC 60068-2-27 for 11 ms
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Noise level 0 dB
Pollution degree 2
Ambient air transport temperature -25…70 °C
Ambient air temperature for operation -10…40 °C without derating
40…60 °C with current derating 2.2 % per °C
ambient air temperature for storage -25…70 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.500 cm
Package 1 Width 18.700 cm
Package 1 Length 19.500 cm
Package 1 Weight 998.000 g
Unit Type of Package 2 S06
Number of Units in Package 2 45
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 58.270 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider ATV12H037M3 | variable speed drive ATV12 – 0.37kW – 0.55hp – 200..240V – 3ph – with heat sink”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024