Schneider ATV212HD37N4: The Ultimate Guide

Introduction

When it comes to efficient motor control in industrial applications, the Schneider ATV212HD37N4 stands out as a reliable and advanced solution. Understanding its features, benefits, and applications can significantly enhance your operational efficiency. This article aims to provide an in-depth look at the Schneider ATV212HD37N4, from its key specifications to practical tips for installation and use.

Understanding the Schneider ATV212HD37N4

What is the Schneider ATV212HD37N4?

The Schneider ATV212HD37N4 is a variable frequency drive (VFD) designed to optimize the performance of HVAC systems and other industrial applications. It provides precise motor control, enhancing the performance and efficiency of your machinery.

Key Features and Specifications

  • Power Rating: 37 kW (50 HP)
  • Input Voltage: 380-480V, 3-phase
  • Output Frequency: 0.5 to 200 Hz
  • Control Type: Vector control with sensorless vector capability
  • Protection: IP20 enclosure, overcurrent, overvoltage, and thermal protection

Benefits of Using the Schneider ATV212HD37N4

  • Energy Efficiency: Reduces energy consumption by optimizing motor speed.
  • Ease of Use: User-friendly interface and simple configuration.
  • Reliability: Robust design ensures long-term performance.
  • Versatility: Suitable for a wide range of applications.

Applications of the Schneider ATV212HD37N4

Common Industries and Use Cases

The Schneider ATV212HD37N4 is commonly used in:

  • HVAC Systems: Ensuring optimal performance and energy efficiency.
  • Pumps and Fans: Controlling speed for better process management.
  • Conveyors: Improving operational efficiency in manufacturing.
  • Water Treatment Facilities: Optimizing pump operation to conserve energy.

Real-World Examples of Implementation

  • Manufacturing Plants: Enhancing production line efficiency.
  • Commercial Buildings: Managing HVAC systems for better climate control.
  • Agricultural Operations: Controlling irrigation systems for better crop management.

Advantages in Specific Applications

  • Precision Control: Achieving desired performance in various processes.
  • Cost Savings: Lowering energy bills and maintenance costs.
  • Improved Durability: Extending the lifespan of your equipment.

Installation and Setup

Pre-installation Considerations

  • Verify Electrical Specifications: Ensure compatibility with your power supply.
  • Check Environmental Conditions: Install in a clean, dry, and well-ventilated area.

Step-by-Step Installation Guide

  1. Mount the VFD: Securely mount the Schneider ATV212HD37N4 on a stable surface.
  2. Connect the Power Supply: Follow the wiring diagram to connect to the power source.
  3. Wire the Motor: Connect the motor terminals to the VFD outputs.
  4. Configure the Settings: Use the interface to set initial parameters.

Initial Setup and Configuration

  • Parameter Setting: Configure parameters like motor voltage, current, and frequency.
  • Test Run: Perform a test run to ensure proper operation.

Operating the Schneider ATV212HD37N4

Basic Operation Principles

  • Start/Stop Control: Use the interface to start and stop the motor.
  • Speed Adjustment: Adjust motor speed using the control panel.

User Interface and Controls

  • LCD Display: Provides real-time data on motor performance.
  • Keypad: Allows for easy parameter adjustments.

Tips for Efficient Operation

  • Regular Monitoring: Keep an eye on performance metrics.
  • Optimal Settings: Fine-tune settings for your specific application.

Maintenance and Troubleshooting

Regular Maintenance Practices

  • Routine Inspections: Check for dust buildup and clean regularly.
  • Firmware Updates: Ensure the VFD firmware is up-to-date.

Common Issues and Their Solutions

  • Overheating: Ensure proper ventilation and reduce load if necessary.
  • Unexpected Shutdowns: Check for electrical faults or parameter errors.

When to Seek Professional Help

  • Complex Issues: If troubleshooting doesn’t resolve the problem, consult a professional.
  • Major Repairs: For significant damage, professional repair is recommended.

Advanced Features and Customization

Overview of Advanced Functionalities

  • Programmable Logic: Customize operations with built-in programming options.
  • Remote Monitoring: Integrate with supervisory systems for remote monitoring.

Customization Options

  • User-defined Parameters: Tailor settings to your specific needs.
  • Interface Options: Choose between different user interfaces for control.

Integrating with Other Systems

  • Communication Protocols: Supports Modbus and other protocols for seamless integration.
  • Automation Systems: Compatible with various automation and control systems.

Energy Efficiency and Cost Savings

How the ATV212HD37N4 Enhances Energy Efficiency

  • Variable Speed Control: Matches motor speed to the actual load requirement.
  • Reduced Power Consumption: Lowers energy usage during low-demand periods.

Cost-saving Benefits

  • Lower Utility Bills: Reduced energy consumption translates to savings.
  • Extended Equipment Life: Proper motor control reduces wear and tear.

Environmental Impact

  • Reduced Carbon Footprint: Lower energy consumption helps in reducing greenhouse gas emissions.
  • Sustainable Operations: Supports your sustainability goals.
Main
Device short name ATV212
product destination Asynchronous motors
Network number of phases 3 phases
Motor power kW 37 kW
Motor power hp 50 hp
Supply voltage limits 323…528 V
Supply frequency 50…60 Hz – 5…5 %
Line current 68.9 A at 380 V
54.4 A at 480 V
Range of product Altivar 212
Product or component type Variable speed drive
Product specific application Pumps and fans in HVAC
Communication port protocol METASYS N2
BACnet
Modbus
APOGEE FLN
LonWorks
[Us] rated supply voltage 380…480 V – 15…10 %
EMC filter Class C2 EMC filter integrated
IP degree of protection IP21
Complementary
Apparent power 52 kVA at 380 V
Continuous output current 79 A at 380 V
79 A at 460 V
Maximum transient current 86.9 A for 60 s
Speed drive output frequency 0.5…200 Hz
Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Local signalling 1 LED (red) for DC bus energized
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14
L1/R, L2/S, L3/T: terminal 50 mm² / AWG 1/0
Tightening torque 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
24 N.m, 212 lb.in (L1/R, L2/S, L3/T)
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Response time FM 2 ms, tolerance +/- 0.5 ms for analog output(s)
FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
Accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C
+/- 0.6 % (VIB) for a temperature variation 60 °C
+/- 1 % (FM) for a temperature variation 60 °C
Linearity error VIA: +/- 0.15 % of maximum value for input
VIB: +/- 0.15 % of maximum value for input
FM: +/- 0.2 % for output
Analogue output type FM switch-configurable voltage 0…10 V DC, impedance: 7620 Ohm, resolution 10 bits
FM switch-configurable current 0…20 mA, impedance: 970 Ohm, resolution 10 bits
Discrete output type Configurable relay logic: (FLA, FLC) NO – 100000 cycles
Configurable relay logic: (FLB, FLC) NC – 100000 cycles
Configurable relay logic: (RY, RC) NO – 100000 cycles
Minimum switching current 3 mA at 24 V DC for configurable relay logic
Maximum switching current 5 A at 250 V AC on resistive load – cos phi = 1 – L/R = 0 ms (FL, R)
5 A at 30 V DC on resistive load – cos phi = 1 – L/R = 0 ms (FL, R)
2 A at 250 V AC on inductive load – cos phi = 0.4 – L/R = 7 ms (FL, R)
2 A at 30 V DC on inductive load – cos phi = 0.4 – L/R = 7 ms (FL, R)
Discrete input type F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
Discrete input logic Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit: 0.1 Hz
Analog input: 0.024/50 Hz
communication service Read holding registers (03) 2 words maximum
Monitoring inhibitable
Write single register (06)
Write multiple registers (16) 2 words maximum
Time out setting from 0.1 to 100 s
Read device identification (43)
Option card Communication card for LonWorks
Power dissipation in W 976 W
Air flow 334 m3/h
Functionality Mid
Specific application HVAC
Variable speed drive application selection Building – HVAC compressor for scroll
Building – HVAC fan
Building – HVAC pump
Motor power range AC-3 30…50 kW at 380…440 V 3 phases
30…50 kW at 480…500 V 3 phases
Motor starter type Variable speed drive
Discrete output number 2
Analogue input number 2
Analogue input type VIA switch-configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable PTC probe: 0…6 probes, impedance: 1500 Ohm
VIA switch-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Physical interface 2-wire RS 485
Connector type 1 open style
1 RJ45
Transmission rate 9600 bps or 19200 bps
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Asynchronous motor control profile Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio, 2 points
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Torque accuracy +/- 15 %
Transient overtorque 120 % of nominal motor torque +/- 10 % for 60 s
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s
Automatic based on the load
Motor slip compensation Not available in voltage/frequency ratio motor control
Automatic whatever the load
Adjustable
Switching frequency 6…16 kHz adjustable
8…16 kHz with derating factor
Nominal switching frequency 8 kHz
Braking to standstill By DC injection
Network frequency 47.5…63 Hz
Prospective line Isc 22 kA
Protection type Overheating protection: drive
Thermal power stage: drive
Short-circuit between motor phases: drive
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overvoltages on the DC bus: drive
Break on the control circuit: drive
Against exceeding limit speed: drive
Line supply overvoltage and undervoltage: drive
Line supply undervoltage: drive
Against input phase loss: drive
Thermal protection: motor
Motor phase break: motor
With PTC probes: motor
Width 240 mm
Height 550 mm
Depth 244 mm
Environment
Pollution degree 3 conforming to IEC 61800-5-1
IP degree of protection IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1
IP20 on upper part without blanking plate on cover conforming to IEC 60529
IP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529
IP41 on upper part conforming to IEC 61800-5-1
IP41 on upper part conforming to IEC 60529
Vibration resistance 1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Environmental characteristic Classes 3C1 conforming to IEC 60721-3-3
Classes 3S2 conforming to IEC 60721-3-3
Noise level 64 dB conforming to 86/188/EEC
Operating altitude 1000…3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m
<= 1000 m without derating
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for operation -10…40 °C (without derating)
40…50 °C (with derating factor)
Operating position Vertical +/- 10 degree
Product certifications UL
NOM 117
C-Tick
CSA
Marking CE
Standards IEC 61800-3 environments 2 category C1
IEC 61800-3 environments 1 category C3
IEC 61800-3 category C3
IEC 61800-3 category C2
IEC 61800-3
IEC 61800-3 environments 1 category C1
IEC 61800-5-1
IEC 61800-3 environments 1 category C1
EN 61800-3 category C3
IEC 61800-3 environments 2 category C2
IEC 61800-3 category C2
IEC 61800-3 environments 2 category C1
IEC 61800-3
IEC 61800-3 environments 1 category C3
UL Type 1
IEC 61800-3 environments 2 category C3
IEC 61800-3 environments 1 category C2
EN 55011 class A group 1
IEC 61800-5-1
IEC 61800-3 environments 1 category C2
IEC 61800-3 environments 2 category C3
IEC 61800-3 environments 2 category C2
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Regulation loop Adjustable PI regulator
ambient air temperature for storage -25…70 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 45 cm
Package 1 Width 38.5 cm
Package 1 Length 70 cm
Package 1 Weight 23.5 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider ATV212HD37N4 | variable speed drive ATV212 – 37kW – 50hp – 480V – 3ph – EMC – IP21”

There are no reviews yet.

SHOPPING CART

close
Let's Chat