Let's Chat
-45%

Schneider ATV212HU22N4 | variable speed drive ATV212 – 2.2kW – 3hp – 480V – 3ph – EMC – IP21

Schneider Electric
Availability:

Out of stock


Schneider ATV212HU22N4 | variable speed drive ATV212 – 2.2kW – 3hp – 480V – 3ph – EMC – IP21

24,484 EGP 44,517 EGP

Out of stock

Compare

Schneider ATV212HU22N4: The Ultimate Guide

Introduction

When it comes to efficient motor control in industrial applications, the Schneider ATV212HU22N4 stands out as a reliable and advanced solution. Understanding its features, benefits, and applications can significantly enhance your operational efficiency. This article aims to provide an in-depth look at it, from its key specifications to practical tips for installation and use.

Understanding the Schneider ATV212HU22N4

What is the Schneider ATV212HU22N4?

it is a variable frequency drive (VFD) designed to optimize the performance of HVAC systems and other industrial applications. It provides precise motor control, enhancing the performance and efficiency of your machinery.

Key Features and Specifications

  • Power Rating: 22 kW (30 HP)
  • Input Voltage: 380-480V, 3-phase
  • Output Frequency: 0.5 to 200 Hz
  • Control Type: Vector control with sensorless vector capability
  • Protection: IP20 enclosure, overcurrent, overvoltage, and thermal protection

Benefits of Using the Schneider ATV212HU22N4

  • Energy Efficiency: Reduces energy consumption by optimizing motor speed.
  • Ease of Use: User-friendly interface and simple configuration.
  • Reliability: Robust design ensures long-term performance.
  • Versatility: Suitable for a wide range of applications.

Applications of the Schneider ATV212HU22N4

Common Industries and Use Cases

it is commonly used in:

  • HVAC Systems: Ensuring optimal performance and energy efficiency.
  • Pumps and Fans: Controlling speed for better process management.
  • Conveyors: Improving operational efficiency in manufacturing.
  • Water Treatment Facilities: Optimizing pump operation to conserve energy.

Real-World Examples of Implementation

  • Manufacturing Plants: Enhancing production line efficiency.
  • Commercial Buildings: Managing HVAC systems for better climate control.
  • Agricultural Operations: Controlling irrigation systems for better crop management.

Advantages in Specific Applications

  • Precision Control: Achieving desired performance in various processes.
  • Cost Savings: Lowering energy bills and maintenance costs.
  • Improved Durability: Extending the lifespan of your equipment.

Installation and Setup

Pre-installation Considerations

  • Verify Electrical Specifications: Ensure compatibility with your power supply.
  • Check Environmental Conditions: Install in a clean, dry, and well-ventilated area.

Step-by-Step Installation Guide

  1. Mount the VFD: Securely mount it on a stable surface.
  2. Connect the Power Supply: Follow the wiring diagram to connect to the power source.
  3. Wire the Motor: Connect the motor terminals to the VFD outputs.
  4. Configure the Settings: Use the interface to set initial parameters.

Initial Setup and Configuration

  • Parameter Setting: Configure parameters like motor voltage, current, and frequency.
  • Test Run: Perform a test run to ensure proper operation.

Operating the Schneider ATV212HU22N4

Basic Operation Principles

  • Start/Stop Control: Use the interface to start and stop the motor.
  • Speed Adjustment: Adjust motor speed using the control panel.

User Interface and Controls

  • LCD Display: Provides real-time data on motor performance.
  • Keypad: Allows for easy parameter adjustments.

Tips for Efficient Operation

  • Regular Monitoring: Keep an eye on performance metrics.
  • Optimal Settings: Fine-tune settings for your specific application.

Maintenance and Troubleshooting

Regular Maintenance Practices

  • Routine Inspections: Check for dust buildup and clean regularly.
  • Firmware Updates: Ensure the VFD firmware is up-to-date.

Common Issues and Their Solutions

  • Overheating: Ensure proper ventilation and reduce load if necessary.
  • Unexpected Shutdowns: Check for electrical faults or parameter errors.

When to Seek Professional Help

  • Complex Issues: If troubleshooting doesn’t resolve the problem, consult a professional.
  • Major Repairs: For significant damage, professional repair is recommended.

Advanced Features and Customization

Overview of Advanced Functionalities

  • Programmable Logic: Customize operations with built-in programming options.
  • Remote Monitoring: Integrate with supervisory systems for remote monitoring.

Customization Options

  • User-defined Parameters: Tailor settings to your specific needs.
  • Interface Options: Choose between different user interfaces for control.

Integrating with Other Systems

  • Communication Protocols: Supports Modbus and other protocols for seamless integration.
  • Automation Systems: Compatible with various automation and control systems.

Energy Efficiency and Cost Savings

How the ATV212HU22N4 Enhances Energy Efficiency

  • Variable Speed Control: Matches motor speed to the actual load requirement.
  • Reduced Power Consumption: Lowers energy usage during low-demand periods.

Cost-saving Benefits

  • Lower Utility Bills: Reduced energy consumption translates to savings.
  • Extended Equipment Life: Proper motor control reduces wear and tear.

Environmental Impact

  • Reduced Carbon Footprint: Lower energy consumption helps in reducing greenhouse gas emissions.
  • Sustainable Operations: Supports your sustainability goals.
SKU: ATV212HU22N4 Category:
Main
Device short name ATV212
product destination Asynchronous motors
Network number of phases 3 phases
Motor power kW 2.2 kW
Motor power hp 3 hp
Supply voltage limits 323…528 V
Supply frequency 50…60 Hz – 5…5 %
Line current 3.6 A at 480 V
4.6 A at 380 V
Range of product Altivar 212
Product or component type Variable speed drive
Product specific application Pumps and fans in HVAC
Communication port protocol BACnet
LonWorks
Modbus
METASYS N2
APOGEE FLN
[Us] rated supply voltage 380…480 V – 15…10 %
EMC filter Class C2 EMC filter integrated
IP degree of protection IP21
Complementary
Apparent power 3.9 kVA at 380 V
Continuous output current 5.1 A at 380 V
5.1 A at 460 V
Maximum transient current 5.6 A for 60 s
Speed drive output frequency 0.5…200 Hz
Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Local signalling 1 LED (red) for DC bus energized
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14
L1/R, L2/S, L3/T: terminal 6 mm² / AWG 10
Tightening torque 1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T)
0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Response time FM 2 ms, tolerance +/- 0.5 ms for analog output(s)
FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
Accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C
+/- 0.6 % (VIB) for a temperature variation 60 °C
+/- 1 % (FM) for a temperature variation 60 °C
Linearity error VIA: +/- 0.15 % of maximum value for input
VIB: +/- 0.15 % of maximum value for input
FM: +/- 0.2 % for output
Analogue output type FM switch-configurable voltage 0…10 V DC, impedance: 7620 Ohm, resolution 10 bits
FM switch-configurable current 0…20 mA, impedance: 970 Ohm, resolution 10 bits
Discrete output type Configurable relay logic: (FLA, FLC) NO – 100000 cycles
Configurable relay logic: (FLB, FLC) NC – 100000 cycles
Configurable relay logic: (RY, RC) NO – 100000 cycles
Minimum switching current 3 mA at 24 V DC for configurable relay logic
Maximum switching current 5 A at 250 V AC on resistive load – cos phi = 1 – L/R = 0 ms (FL, R)
5 A at 30 V DC on resistive load – cos phi = 1 – L/R = 0 ms (FL, R)
2 A at 250 V AC on inductive load – cos phi = 0.4 – L/R = 7 ms (FL, R)
2 A at 30 V DC on inductive load – cos phi = 0.4 – L/R = 7 ms (FL, R)
Discrete input type F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
Discrete input logic Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit: 0.1 Hz
Analog input: 0.024/50 Hz
communication service Write single register (06)
Read device identification (43)
Time out setting from 0.1 to 100 s
Read holding registers (03) 2 words maximum
Write multiple registers (16) 2 words maximum
Monitoring inhibitable
Option card Communication card for LonWorks
Power dissipation in W 103 W
Air flow 35 m3/h
Functionality Mid
Specific application HVAC
Variable speed drive application selection Building – HVAC compressor for scroll
Building – HVAC fan
Building – HVAC pump
Motor power range AC-3 2.2…3 kW at 380…440 V 3 phases
2.2…3 kW at 480…500 V 3 phases
Motor starter type Variable speed drive
Discrete output number 2
Analogue input number 2
Analogue input type VIA switch-configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable PTC probe: 0…6 probes, impedance: 1500 Ohm
VIA switch-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Physical interface 2-wire RS 485
Connector type 1 open style
1 RJ45
Transmission rate 9600 bps or 19200 bps
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Asynchronous motor control profile Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 2 points
Torque accuracy +/- 15 %
Transient overtorque 120 % of nominal motor torque +/- 10 % for 60 s
Acceleration and deceleration ramps Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
Motor slip compensation Not available in voltage/frequency ratio motor control
Adjustable
Automatic whatever the load
Switching frequency 6…16 kHz adjustable
12…16 kHz with derating factor
Nominal switching frequency 12 kHz
Braking to standstill By DC injection
Network frequency 47.5…63 Hz
Prospective line Isc 5 kA
Protection type Overheating protection: drive
Thermal power stage: drive
Short-circuit between motor phases: drive
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overvoltages on the DC bus: drive
Break on the control circuit: drive
Against exceeding limit speed: drive
Line supply overvoltage and undervoltage: drive
Line supply undervoltage: drive
Against input phase loss: drive
Thermal protection: motor
Motor phase break: motor
With PTC probes: motor
Width 107 mm
Height 143 mm
Depth 150 mm
Net weight 2 kg
Environment
Pollution degree 3 conforming to IEC 61800-5-1
IP degree of protection IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1
IP20 on upper part without blanking plate on cover conforming to IEC 60529
IP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529
IP41 on upper part conforming to IEC 61800-5-1
IP41 on upper part conforming to IEC 60529
Vibration resistance 1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Environmental characteristic Classes 3C1 conforming to IEC 60721-3-3
Classes 3S2 conforming to IEC 60721-3-3
Noise level 51 dB conforming to 86/188/EEC
Operating altitude 1000…3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m
<= 1000 m without derating
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for operation -10…40 °C (without derating)
40…50 °C (with derating factor)
Operating position Vertical +/- 10 degree
Product certifications CSA
NOM 117
UL
C-Tick
Marking CE
Standards IEC 61800-3
IEC 61800-5-1
IEC 61800-3 environments 1 category C2
IEC 61800-3 environments 1 category C2
IEC 61800-3
IEC 61800-3 environments 2 category C3
IEC 61800-3 environments 1 category C1
IEC 61800-3 environments 1 category C3
IEC 61800-3 category C3
IEC 61800-3 environments 2 category C1
UL Type 1
EN 61800-3 category C3
IEC 61800-3 environments 1 category C3
IEC 61800-3 category C2
IEC 61800-3 environments 2 category C2
IEC 61800-3 environments 2 category C3
EN 55011 class A group 1
IEC 61800-3 environments 2 category C2
IEC 61800-3 environments 2 category C1
IEC 61800-5-1
IEC 61800-3 category C2
IEC 61800-3 environments 1 category C1
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Regulation loop Adjustable PI regulator
ambient air temperature for storage -25…70 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 17.500 cm
Package 1 Width 17.500 cm
Package 1 Length 20.500 cm
Package 1 Weight 1.962 kg
Unit Type of Package 2 S06
Number of Units in Package 2 27
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 66.028 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider ATV212HU22N4 | variable speed drive ATV212 – 2.2kW – 3hp – 480V – 3ph – EMC – IP21”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024