-45%
, , ,

Schneider ATV320U06M2C412 | Variable speed drive, Altivar Solar, 0.55kW, 200 to 240V, 1 phase, compact Altivar Solar

Availability:

Out of stock


Schneider ATV320U06M2C412 | Variable speed drive, Altivar Solar, 0.55kW, 200 to 240V, 1 phase, compact Altivar Solar
Easy scalability of your Automation system
Future-ready solution for Industry 4.0
Improve power quality of your system with a low investment
Improve the safety, integration, and performance of your application
Optimize your maintenance cost and the Drives Lifetime

12,212.71 EGP 22,204.92 EGP

Out of stock

Schneider ATV320U06M2C412 | Variable speed drive, Altivar Solar, 0.55kW, 200 to 240V, 1 phase, compact Altivar Solar

 

The Schneider Altivar ATV320U06M2C412 is a compact variable speed drive (VSD) specifically designed for solar water pumping applications. It is rated at 0.55 kW and operates on a single-phase voltage of 200 to 240V.

Key Features and Benefits

This drive’s primary function is to efficiently convert variable DC power from solar panels into a stable AC output to run a pump motor. A core feature is its Maximum Power Point Tracking (MPPT) capability, which continuously adjusts the motor’s speed to draw the maximum possible power from the solar array. This intelligent control ensures the pump’s output is optimized throughout the day, maximizing water delivery.

The drive has a compact, book-style form factor that saves valuable space in control cabinets. It offers robust integrated safety functions, including Safe Torque Off (STO), which helps prevent unexpected motor startup and simplifies compliance with safety standards. It also features built-in pump-specific protections, such as dry-run protection, to automatically shut off the pump when the water level is too low, preventing damage. The drive can be used with a dual power supply, allowing it to switch between solar power and a conventional AC grid, which provides operational flexibility during cloudy periods or at night.

Primary Applications

The Schneider Altivar ATV320U06M2C412 is well-suited for a variety of small-scale water pumping needs, particularly in remote or off-grid locations. Its main uses include:

Small-scale agricultural irrigation for crops, gardens, and greenhouses.

Domestic water supply for single-family homes or small communities.

Livestock watering in rural areas without access to grid electricity.

Water transfer for filling storage tanks in remote locations.

Range of product Altivar Solar
Product or component type Variable speed drive
Product specific application Pumping applications
Variant Standard version
Format of the drive Compact
Mounting mode Wall mount
Communication port protocol Modbus serial
CANopen
Option card Communication module, Ethernet IP/Modbus TCP
[Us] rated supply voltage 200…240 V – 15…10 %
nominal output current 3.7 A
Motor power kW 0.55 kW for heavy duty
EMC filter Class C2 EMC filter integrated
IP degree of protection IP20
Degree of protection UL type 1 standard version
Complementary
Discrete input number 6
Discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1…DI6 logic inputs, 24 V DC (30 V)
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Discrete input logic Positive logic (source)
Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage: 0…10 V DC, impedance: 30 kOhm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits
AI3 current: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Analogue output type Software-configurable current AQ1: 0…20 mA impedance 800 Ohm, resolution 10 bits
Software-configurable voltage AQ1: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Relay output number 2
Relay output type Configurable relay logic R1A 1 NO electrical durability 100000 cycles
Configurable relay logic R1B 1 NC electrical durability 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO electrical durability 100000 cycles
Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Physical interface 2-wire RS 485
Connector type 1 RJ45
Method of access Slave CANopen
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps
Transmission frame RTU
Number of addresses 1…247
1…127
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio – Energy Saving, quadratic U/f
Flux vector control without sensor – Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Torque accuracy +/- 15 %
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 6000 s
Motor slip compensation Automatic whatever the load
Adjustable 0…300 %
Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2…16 kHz adjustable
4…16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Minimum braking resistance 60 Ohm
Line current 7.8 A at 200 V (heavy duty)
6.6 A at 240 V (heavy duty)
Maximum input current 7.8 A
Maximum output voltage 240 V
Apparent power 1.6 kVA at 240 V (heavy duty)
Maximum transient current 5.6 A during 60 s
Short-circuit protection thermal protection
Network frequency 50…60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 1 kA
Base load current at high overload 1.5 A
Power dissipation in W Self-cooled: 33.0 W at 200 V, switching frequency 4 kHz
Electrical connection Screw terminal, clamping capacity: 0.5…1.5 mm² for analog input
Screw terminal for analog output
Screw terminal
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: drive
Width 72.0 mm
Height 143.0 mm
Depth 138.0 mm
Net weight 1.1 kg
Power factor 0.535 at 230 V
Braking torque 170 % with braking resistor
Local signalling 1 LED (red) for drive fault
1 LED (red) for CANopen error
1 LED (green) for CANopen run
Transient overtorque 170…200 % of nominal motor torque
Environment
Operating position Vertical +/- 10 degree
Product certifications CE
UR
UKCA
RCM
Marking CE
UR
UKCA
RCM
Standards IEC 61800-5-1
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13…200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz
Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3
Overvoltage category II
Regulation loop Adjustable PID regulator
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Pollution degree 2
Ambient air transport temperature -25…70 °C
Ambient air temperature for operation -10…50 °C without derating
50…60 °C with derating factor
Ambient air temperature for storage -25…70 °C
Operating altitude 1000…2000 m with current derating 1 % per 100 m
<= 1000 m without derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.5 cm
Package 1 Width 18.7 cm
Package 1 Length 19 cm
Package 1 Weight 1.339 kg
Unit Type of Package 2 S06
Number of Units in Package 2 45
Package 2 Height 75 cm
Package 2 Width 60 cm
Package 2 Length 80 cm
Package 2 Weight 73.255 kg
Range of product Altivar Solar
Product or component type Variable speed drive
Product specific application Pumping applications
Variant Standard version
Format of the drive Compact
Mounting mode Wall mount
Communication port protocol Modbus serial CANopen
Option card Communication module, Ethernet IP/Modbus TCP
[Us] rated supply voltage 200...240 V - 15...10 %
nominal output current 3.7 A
Motor power kW 0.55 kW for heavy duty
EMC filter Class C2 EMC filter integrated
IP degree of protection IP20
Degree of protection UL type 1 standard version
Complementary
Discrete input number 6
Discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1...DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Discrete input logic Positive logic (source) Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Analogue output type Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Relay output number 2
Relay output type Configurable relay logic R1A 1 NO electrical durability 100000 cycles Configurable relay logic R1B 1 NC electrical durability 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000 cycles Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Physical interface 2-wire RS 485
Connector type 1 RJ45
Method of access Slave CANopen
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps
Transmission frame RTU
Number of addresses 1…247 1…127
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Torque accuracy +/- 15 %
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 6000 s
Motor slip compensation Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2...16 kHz adjustable 4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Minimum braking resistance 60 Ohm
Line current 7.8 A at 200 V (heavy duty) 6.6 A at 240 V (heavy duty)
Maximum input current 7.8 A
Maximum output voltage 240 V
Apparent power 1.6 kVA at 240 V (heavy duty)
Maximum transient current 5.6 A during 60 s
Short-circuit protection thermal protection
Network frequency 50...60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 1 kA
Base load current at high overload 1.5 A
Power dissipation in W Self-cooled: 33.0 W at 200 V, switching frequency 4 kHz
Electrical connection Screw terminal, clamping capacity: 0.5...1.5 mm² for analog input Screw terminal for analog output Screw terminal
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive
Width 72.0 mm
Height 143.0 mm
Depth 138.0 mm
Net weight 1.1 kg
Power factor 0.535 at 230 V
Braking torque 170 % with braking resistor
Local signalling 1 LED (red) for drive fault 1 LED (red) for CANopen error 1 LED (green) for CANopen run
Transient overtorque 170…200 % of nominal motor torque
Environment
Operating position Vertical +/- 10 degree
Product certifications CE UR UKCA RCM
Marking CE UR UKCA RCM
Standards IEC 61800-5-1
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3
Overvoltage category II
Regulation loop Adjustable PID regulator
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Pollution degree 2
Ambient air transport temperature -25…70 °C
Ambient air temperature for operation -10…50 °C without derating 50…60 °C with derating factor
Ambient air temperature for storage -25…70 °C
Operating altitude 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.5 cm
Package 1 Width 18.7 cm
Package 1 Length 19 cm
Package 1 Weight 1.339 kg
Unit Type of Package 2 S06
Number of Units in Package 2 45
Package 2 Height 75 cm
Package 2 Width 60 cm
Package 2 Length 80 cm
Package 2 Weight 73.255 kg

date sheet

date sheet

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider ATV320U06M2C412 | Variable speed drive, Altivar Solar, 0.55kW, 200 to 240V, 1 phase, compact Altivar Solar”

There are no reviews yet.

SHOPPING CART

close