-45%
, , ,

Schneider ATV320U75M3C412 | Variable speed drive, Altivar Solar, 7.5kW, 200 to 240V, 3 phases, compact

Schneider Electric
Availability:

Out of stock


Schneider ATV320U75M3C412 | Variable speed drive, Altivar Solar, 7.5kW, 200 to 240V, 3 phases, compact
Easy scalability of your Automation system
Future-ready solution for Industry 4.0
Improve power quality of your system with a low investment
Improve the safety, integration, and performance of your application
Optimize your maintenance cost and the Drives Lifetime

37,881.46 EGP 68,875.38 EGP

Out of stock

Schneider ATV320U75M3C412 | Variable speed drive, Altivar Solar, 7.5kW, 200 to 240V, 3 phases, compact

 

The Schneider Altivar ATV320U75M3C412 is a compact variable speed drive (VSD) from the Altivar Solar series. It is designed for efficient and reliable operation of solar water pumping systems. The drive has a rated power of 7.5 kW and operates on a three-phase voltage supply of 200 to 240V.

Key Features and Benefits

This drive is engineered to maximize the efficiency of solar-powered pump applications. Its primary feature is Maximum Power Point Tracking (MPPT), an algorithm that continuously monitors the solar panels’ output and adjusts the motor’s speed to utilize the maximum available power. This ensures the pump delivers the highest possible water flow throughout the day, even with fluctuating sunlight.

The drive is built in a compact, book-style form factor to save space in control cabinets and features an integrated C2 EMC filter to reduce electromagnetic interference. It includes a range of integrated safety functions, such as Safe Torque Off (STO), which prevents unexpected motor startup. It also has built-in pump-specific protection features like dry-run protection, which automatically shuts off the pump when the water source is depleted, preventing damage. The drive can also be configured to operate on a dual power supply, using either a solar array or a conventional AC grid for continuous operation.

Primary Applications

The Schneider Altivar ATV320U75M3C412 is a robust solution for a variety of medium to large-scale solar pumping needs, particularly in remote or off-grid areas. Its main applications include:

Agricultural Irrigation: Providing water for farms and large greenhouses.

Community Water Supply: Supplying water to villages and rural communities.

Water Transfer and Distribution: Pumping water for filling large tanks, reservoirs, and water distribution networks.

Livestock Watering: Ensuring a reliable and consistent water supply for large herds in remote pastures.

brands

Main
Range of product Altivar Solar
Product or component type Variable speed drive
Product specific application Pumping applications
Variant Standard version
Format of the drive Compact
Mounting mode Wall mount
Communication port protocol Modbus serial
CANopen
Option card Communication module, Ethernet IP/Modbus TCP
[Us] rated supply voltage 200…240 V – 15…10 %
nominal output current 33.0 A
Motor power kW 7.5 kW for heavy duty
EMC filter Without EMC filter
IP degree of protection IP20
Complementary
Discrete input number 7
Discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1…DI6 logic inputs, 24 V DC (30 V)
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Discrete input logic Positive logic (source)
Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage: 0…10 V DC, impedance: 30 kOhm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits
AI3 current: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Analogue output type Software-configurable current AQ1: 0…20 mA impedance 800 Ohm, resolution 10 bits
Software-configurable voltage AQ1: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Relay output number 2
Relay output type Configurable relay logic R1A 1 NO electrical durability 100000 cycles
Configurable relay logic R1B 1 NC electrical durability 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO electrical durability 100000 cycles
Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Method of access Slave CANopen
Number of addresses 1…247
1…127
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio – Energy Saving, quadratic U/f
Flux vector control without sensor – Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 6000 s
Motor slip compensation Automatic whatever the load
Adjustable 0…300 %
Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2…16 kHz adjustable
4…16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 45.3 A at 200 V (heavy duty)
38.2 A at 240 V (heavy duty)
Maximum input current 45.3 A
Maximum output voltage 240 V
Apparent power 15.9 kVA at 240 V (heavy duty)
Maximum transient current 49.5 A during 60 s
Short-circuit protection thermal protection
Network frequency 50…60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 22 kA
Base load current at high overload 33.0 A
Power dissipation in W Fan: 293.0 W at 200 V, switching frequency 4 kHz
Electrical connection Screw terminal, clamping capacity: 0.5…1.5 mm² for analog input
Screw terminal for analog output
Screw terminal
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: drive
Width 150 mm
Height 232.0 mm
Depth 178.0 mm
Net weight 3.6 kg
Power factor 0.574 at 230 V
Braking torque 170 % with braking resistor
Local signalling 1 LED (red) for drive fault
1 LED (red) for CANopen error
1 LED (green) for CANopen run
Transient overtorque 170…200 % of nominal motor torque
Environment
Operating position Vertical +/- 10 degree
Product certifications CE
UR
UKCA
RCM
Marking CE
UR
UKCA
RCM
Standards IEC 61800-5-1
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13…200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz
Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3
Volume of cooling air 60 m3/h
Overvoltage category II
Regulation loop Adjustable PID regulator
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Noise level 54 dB
Pollution degree 2
Ambient air transport temperature -25…70 °C
Ambient air temperature for operation -10…50 °C without derating
50…60 °C with derating factor
Ambient air temperature for storage -25…70 °C
Operating altitude 1000…2000 m with current derating 1 % per 100 m
<= 1000 m without derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.5 cm
Package 1 Width 22 cm
Package 1 Length 33 cm
Package 1 Weight 4.291 kg
Unit Type of Package 2 S06
Number of Units in Package 2 10
Package 2 Height 75 cm
Package 2 Width 60 cm
Package 2 Length 80 cm
Package 2 Weight 55.91 kg
Main
Range of product Altivar Solar
Product or component type Variable speed drive
Product specific application Pumping applications
Variant Standard version
Format of the drive Compact
Mounting mode Wall mount
Communication port protocol Modbus serial CANopen
Option card Communication module, Ethernet IP/Modbus TCP
[Us] rated supply voltage 200...240 V - 15...10 %
nominal output current 33.0 A
Motor power kW 7.5 kW for heavy duty
EMC filter Without EMC filter
IP degree of protection IP20
Complementary
Discrete input number 7
Discrete input type STO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1...DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Discrete input logic Positive logic (source) Negative logic (sink)
Discrete output number 3
Discrete output type Open collector DQ+ 0…1 kHz 30 V DC 100 mA Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number 3
Analogue input type AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Analogue output number 1
Analogue output type Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Relay output number 2
Relay output type Configurable relay logic R1A 1 NO electrical durability 100000 cycles Configurable relay logic R1B 1 NC electrical durability 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000 cycles Configurable relay logic R2C
Maximum switching current Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum switching current Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Method of access Slave CANopen
Number of addresses 1…247 1…127
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance
4 quadrant operation possible True
Asynchronous motor control profile Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control profile Vector control without sensor
Maximum output frequency 0.599 kHz
Acceleration and deceleration ramps Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 6000 s
Motor slip compensation Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency 2...16 kHz adjustable 4...16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated True
Line current 45.3 A at 200 V (heavy duty) 38.2 A at 240 V (heavy duty)
Maximum input current 45.3 A
Maximum output voltage 240 V
Apparent power 15.9 kVA at 240 V (heavy duty)
Maximum transient current 49.5 A during 60 s
Short-circuit protection thermal protection
Network frequency 50...60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 22 kA
Base load current at high overload 33.0 A
Power dissipation in W Fan: 293.0 W at 200 V, switching frequency 4 kHz
Electrical connection Screw terminal, clamping capacity: 0.5...1.5 mm² for analog input Screw terminal for analog output Screw terminal
With safety function Safely Limited Speed (SLS) True
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) True
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) True
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
Protection type Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive
Width 150 mm
Height 232.0 mm
Depth 178.0 mm
Net weight 3.6 kg
Power factor 0.574 at 230 V
Braking torque 170 % with braking resistor
Local signalling 1 LED (red) for drive fault 1 LED (red) for CANopen error 1 LED (green) for CANopen run
Transient overtorque 170…200 % of nominal motor torque
Environment
Operating position Vertical +/- 10 degree
Product certifications CE UR UKCA RCM
Marking CE UR UKCA RCM
Standards IEC 61800-5-1
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
Permitted relative humidity (during operation) Class 3K5 according to EN 60721-3
Volume of cooling air 60 m3/h
Overvoltage category II
Regulation loop Adjustable PID regulator
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Noise level 54 dB
Pollution degree 2
Ambient air transport temperature -25…70 °C
Ambient air temperature for operation -10…50 °C without derating 50…60 °C with derating factor
Ambient air temperature for storage -25…70 °C
Operating altitude 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 19.5 cm
Package 1 Width 22 cm
Package 1 Length 33 cm
Package 1 Weight 4.291 kg
Unit Type of Package 2 S06
Number of Units in Package 2 10
Package 2 Height 75 cm
Package 2 Width 60 cm
Package 2 Length 80 cm
Package 2 Weight 55.91 kg

date sheet

date sheet

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider ATV320U75M3C412 | Variable speed drive, Altivar Solar, 7.5kW, 200 to 240V, 3 phases, compact”

There are no reviews yet.

SHOPPING CART

close