Introduction

Schneider Electric is a global leader in energy management and automation. Their products are known for their quality, reliability, and innovative features. Understanding the specifications and functionalities of their products, such as the Schneider C10B42D040, is essential for professionals in the electrical industry. This article will provide a comprehensive overview of the Schneider C10B42D040, including its features, technical specifications, applications, and more.

Understanding the Schneider C10B42D040

The Schneider C10B42D040 is a miniature circuit breaker (MCB) designed to protect electrical circuits from damage caused by overloads and short circuits. It is suitable for use in residential, commercial, and industrial settings.

Basic Description

The Schneider C10B42D040 is a four-pole, 40A circuit breaker with a B curve. This means it trips between 3 to 5 times the rated current, making it suitable for applications where inrush currents are not typically high.

Key Features

  • Four-Pole Protection: Provides comprehensive protection for three-phase electrical systems.
  • Compact Design: Saves space in electrical panels.
  • High Breaking Capacity: Ensures effective protection against electrical faults.
  • Easy Installation: Designed for quick and straightforward installation.
  • Durability: Built with high-quality materials for long-lasting performance.

Technical Specifications

Electrical Specifications

  • Rated Voltage: 400V AC
  • Rated Current: 40A
  • Breaking Capacity: 10kA according to IEC/EN 60898-1
  • Tripping Curve: Type B (3-5 times the rated current)

Mechanical Specifications

  • Dimensions: 81mm x 108mm x 70mm
  • Weight: 0.6 kg
  • Mounting: DIN rail

Design and Construction

The Schneider C10B42D040 is designed for durability and efficiency, ensuring reliable performance over its lifetime.

Materials Used

  • Housing: Fire-resistant plastic
  • Internal Components: High-grade copper and silver alloy
  • Terminals: Corrosion-resistant metal

Build Quality

Schneider Electric adheres to rigorous manufacturing standards to ensure each unit meets high quality and safety standards. The C10B42D040 is built to withstand regular use in various environments.

Installation and Setup

Proper installation is critical to ensure the effective performance of the Schneider C10B42D040. Here’s a step-by-step guide to help you install it correctly.

Pre-Installation Requirements

  • Ensure the main power supply is turned off.
  • Verify that the electrical panel can accommodate the MCB.
  • Gather necessary tools and safety gear.

Step-by-Step Installation Guide

  1. Turn Off Main Power: Ensure the main power supply is off to prevent accidents.
  2. Mount the MCB: Secure the C10B42D040 onto the DIN rail in the electrical panel.
  3. Connect Wires: Attach the input and output wires to the respective terminals, ensuring tight connections.
  4. Test the Installation: Restore power and test the MCB to ensure it functions correctly.
  5. Finalize Installation: Secure any loose wires and close the panel.

Applications and Use Cases

The Schneider C10B42D040 is versatile, making it suitable for various applications.

Performance Metrics

  • Response Time: Fast tripping response to electrical faults.
  • Reliability: High reliability ensures consistent protection with minimal maintenance.

Energy Efficiency

The C10B42D040 is designed to minimize energy loss, contributing to the overall efficiency of the electrical system.

Safety Features

Safety is a paramount concern for Schneider Electric, and the C10B42D040 includes several built-in safety features.

Safety Standards Compliance

The C10B42D040 complies with international safety standards, including IEC/EN 60898-1, ensuring it meets stringent safety requirements.

Built-In Safety Mechanisms

  • Overload Protection: Automatically trips to prevent overheating and potential fires.
  • Short Circuit Protection: Quickly isolates faults to prevent damage to the electrical system.

SKU: C10B42D040 Categories: ,
brands

Schneider Electric

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100B
product or component type Circuit breaker
Device application Distribution
poles description 4P
Protected poles description 4D
3D + N/2
3D
Neutral position Left
[In] rated current 40 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Performance level B 25 kA 415 V AC
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Trip unit protection functions LSoI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
7 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole 1.34 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 40 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 18…40 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 400 s at 1.5 x Ir
16 s at 6 x Ir
11 s at 7.2 x Ir
Neutral protection settings 0.5 x Ir (3D + N/2)
1 x Ir (4D)
No protection (3D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5…10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 600 A
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Number of slots for electrical auxiliaries 5 slot(s)
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.4 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.000 cm
Package 1 Width 18.000 cm
Package 1 Length 18.000 cm
Package 1 Weight 2.381 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10B42D040 | Circuit breaker ComPacT NSX100B, 25kA at 415VAC, MicroLogic 2.2 trip unit 40A, 4 poles 4d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024