Schneider C10B6TM040 | Circuit breaker ComPacT NSX100B, 25kA at 415VAC, TMD trip unit 40A, 4 poles 3d

Schneider C10B6TM040 Description

This ComPacT NSX100B is a complete 4P 3d fixed circuit breaker designed to optimize space and breaking capacity.
It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz.
The operational voltage is 690VAC 50/60Hz.
This product embeds a 40A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection.
This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories.
It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.
ComPacT NSX100B is part of Schneider Electric EcoStruxure Power architecture.

Introduction

Schneider Electric is a globally recognized leader in energy management and automation solutions, known for its high-quality and reliable products. The Schneider C10B6TM040 is a prominent example in their range of miniature circuit breakers (MCBs), celebrated for its outstanding performance and dependability. This article delves into the features, specifications, and applications of the Schneider C10B6TM040, providing valuable insights for both professionals and consumers.

Understanding the Schneider C10B6TM040

The Schneider C10B6TM040 is a miniature circuit breaker designed to protect electrical circuits from overloads and short circuits. It is ideally suited for residential, commercial, and light industrial applications where reliable circuit protection is essential.

Basic Description

The Schneider C10B6TM040 is a single-pole, 40A circuit breaker with a B curve characteristic, meaning it trips between 3 to 5 times the rated current. This makes it suitable for circuits with moderate inrush currents such as lighting and socket outlets.

Key Features

  • Single-Pole Protection: Provides protection for individual circuits.
  • Compact Size: Easily fits into standard electrical panels, saving space.
  • High Breaking Capacity: Capable of interrupting high fault currents to protect electrical systems.
  • User-Friendly Installation: Designed for easy and quick installation.
  • Robust Construction: Made from high-quality materials ensuring long-lasting performance.

Technical Specifications

Electrical Specifications

  • Rated Voltage: 230/400V AC
  • Rated Current: 40A
  • Breaking Capacity: 10kA according to IEC/EN 60898-1
  • Tripping Curve: Type B (3-5 times the rated current)

Mechanical Specifications

  • Dimensions: 81mm x 18mm x 70mm
  • Weight: 0.125 kg
  • Mounting: DIN rail

Design and Construction

The Schneider C10B6TM040 is built to deliver reliable performance under various conditions.

Materials Used

  • Housing: Durable, fire-resistant plastic
  • Internal Components: High-grade copper and silver alloy
  • Terminals: Made from corrosion-resistant metal for enhanced longevity

Build Quality

Schneider Electric maintains strict quality control standards to ensure each circuit breaker meets high performance and safety criteria. The C10B6TM040 is designed to withstand regular use in demanding environments.

Installation and Setup

Proper installation of the Schneider C10B6TM040 is crucial for its effective performance and safety.

Pre-Installation Requirements

  • Ensure the main power supply is turned off.
  • Verify compatibility with the existing electrical panel.
  • Gather necessary tools and personal protective equipment.

Step-by-Step Installation Guide

  1. Turn Off Main Power: Ensure the main power supply is switched off to prevent accidents.
  2. Mount the MCB: Attach the C10B6TM040 to the DIN rail in the electrical panel securely.
  3. Connect Wires: Attach the input and output wires to the respective terminals, ensuring they are tightly secured.
  4. Test the Installation: Restore power and test the circuit breaker to ensure it is functioning correctly.
  5. Finalize Installation: Organize and secure any loose wires and close the panel.

Maintenance and Troubleshooting

Regular maintenance helps ensure the Schneider C10B6TM040 continues to operate effectively.

Regular Maintenance Tips

  • Visual Inspection: Regularly inspect the circuit breaker for signs of wear or damage.
  • Testing: Periodically test the circuit breaker to ensure it functions correctly.
  • Cleaning: Keep the breaker and surrounding area clean and free of dust.

Common Issues and Solutions

  • Frequent Tripping: This may indicate an overload condition; verify that the connected load is within the breaker’s rated capacity.
  • Loose Connections: Check and tighten any loose wire connections to prevent arcing and potential faults.

Customer Support and Warranty

Schneider Electric offers robust customer support and warranty services for the C10B6TM040.

Warranty Details

The C10B6TM040 comes with a manufacturer’s warranty covering defects in materials and workmanship for a specified period.

Customer Support Channels

  • Technical Support: Available via phone and email for assistance with installation, troubleshooting, and maintenance.
  • Online Resources: Access to manuals, FAQs, and video tutorials on the Schneider Electric website.

Pros and Cons

Advantages of Schneider C10B6TM040

  • Reliable Protection: Effective protection against overloads and short circuits.
  • Durable Construction: High-quality materials ensure longevity and reliability.
  • Easy Installation: User-friendly design simplifies the installation proce
SKU: C10B6TM040 Categories: ,
brands

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100B
product or component type Circuit breaker
Device application Distribution
poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 40 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Performance level B 25 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
7 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole 5.47 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 40 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 500 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.4 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 13.5 cm
Package 1 Width 14.5 cm
Package 1 Length 19 cm
Package 1 Weight 2.361 kg
Unit Type of Package 2 CAR
Number of Units in Package 2 6
Package 2 Height 23 cm
Package 2 Width 39 cm
Package 2 Length 49 cm
Package 2 Weight 15.0515 kg
Unit Type of Package 3 PAL
Number of Units in Package 3 48
Package 3 Height 107 cm
Package 3 Width 40 cm
Package 3 Length 60 cm
Package 3 Weight 125.412 kg

Main Document

Data Sheet : C10B6TM040

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10B6TM040 | Circuit breaker ComPacT NSX100B, 25kA at 415VAC, TMD trip unit 40A, 4 poles 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024