Let's Chat
-34%
,

Schneider C10B6TM063 Compact | Circuit breaker, ComPacT NSX100B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 63A

Schneider Electric
Availability:

In stock


Schneider C10B6TM063 Compact

11,783 EGP 17,852 EGP

In stock

Compare

Schneider C10B6TM063 Compact

Introduction

Schneider Electric is a global leader in electrical solutions, known for its innovative products and reliable performance. Among its offerings, it circuit breaker stands out for its compact design and efficient functionality. In this article, we’ll explore the features, specifications, and benefits of this versatile circuit breaker.

Understanding the Schneider C10B6TM063 Compact

What is the Schneider C10B6TM063 Compact?

it is a circuit breaker designed to protect electrical circuits from overloads, short circuits, and other electrical faults. Its compact size makes it suitable for installations where space is limited, without compromising on performance or safety.

Key Features and Specifications

Some of the key features of it:

  • Compact design: Saves space and simplifies installation.
  • High performance: Capable of handling high current loads efficiently.
  • Safety features: Includes mechanisms for thermal and magnetic protection to ensure safe operation.

The Importance of Circuit Breakers

What is a Circuit Breaker?

A circuit breaker is an essential safety device in any electrical system, designed to automatically interrupt the flow of electricity when a fault is detected. This helps prevent damage to the system and reduces the risk of electrical hazards such as fires or equipment damage.

Role in Electrical Safety

Circuit breakers play a crucial role in maintaining electrical safety by:

  • Preventing overloads: They interrupt the flow of excessive current to prevent overheating and damage to wiring and equipment.
  • Protecting against short circuits: They quickly disconnect the circuit in the event of a short circuit, minimizing damage and risk.

Detailed Features of the C10B6TM063

Compact Design

it design makes it ideal for installations where space is limited, such as in electrical panels or distribution boards.

Performance Capabilities

Despite its small size, the C10B6TM063 is capable of handling high current loads efficiently, ensuring reliable protection for electrical systems.

Safety Features

This circuit breaker is equipped with advanced safety features, including thermal and magnetic protection mechanisms, to ensure safe and reliable operation under various conditions.

Technical Specifications

Electrical Ratings

  • Rated current: Up to 63A
  • Breaking capacity: High breaking capacity suitable for a wide range of applications

Mechanical Endurance

The C10B6TM063 is built to last, with high mechanical endurance to withstand frequent operation.

Environmental Conditions

It is suitable for use in various environmental conditions, making it versatile for both indoor and outdoor applications.

Applications of the C10B6TM063 Compact

Industrial Use

In industrial settings, the C10B6TM063 provides reliable protection for machinery and equipment, helping to minimize downtime and ensure safety.

Commercial Use

For commercial buildings, this circuit breaker ensures the safety and reliability of essential electrical systems such as lighting, heating, and air conditioning.

Residential Use

In residential applications, the C10B6TM063 protects household electrical systems and appliances from potential hazards, providing peace of mind for homeowners.

Installation and Setup

Step-by-Step Installation Guide

  1. Turn off the main power supply.
  2. Mount the circuit breaker in the designated panel.
  3. Connect the input and output wires securely.
  4. Ensure all connections are tight and secure.
  5. Turn on the power and test the circuit breaker.

Important Considerations During Installation

  • Follow manufacturer guidelines: Adhere to the installation instructions provided by Schneider Electric.
  • Check connections: Ensure all electrical connections are properly secured to prevent faults.

Maintenance and Troubleshooting

Routine Maintenance Tips

  • Regular inspections: Periodically inspect the circuit breaker for signs of wear or damage.
  • Cleaning: Keep the breaker and its surroundings clean to prevent dust buildup.

Common Issues and How to Fix Them

  • Frequent tripping: This may indicate an overload or fault in the circuit. Check the load distribution and inspect for any faults.
  • Loose connections: Ensure all connections are tight and secure.

Comparing the C10B6TM063 to Other Models

Comparison with Other Schneider Models

The C10B6TM063 offers a balance of performance, reliability, and affordability compared to other Schneider models in its range.

Comparison with Competitor Products

Compared to competitor products, the C10B6TM063 often provides superior performance and safety features, making it a preferred choice for many users.

Benefits of Using Schneider C10B6TM063 Compact

Enhanced Safety

The C10B6TM063’s advanced safety features provide maximum protection for electrical systems, minimizing the risk of accidents or damage.

SKU: C10B6TM063 Categories: ,
Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100B
Product or component typee Circuit breaker
Device application Distribution
Poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 63 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Performance level B 25 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
7 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole 8.61 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 63 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 500 A
earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.4 kg
Environment
Standards EN/IEC 60947
product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 13.5 cm
Package 1 Width 14.5 cm
Package 1 Length 19 cm
Package 1 Weight 2.307 kg
Unit Type of Package 2 CAR
Number of Units in Package 2 6
Package 2 Height 23 cm
Package 2 Width 39 cm
Package 2 Length 49 cm
Package 2 Weight 14.7275 kg
Unit Type of Package 3 PAL
Number of Units in Package 3 48
Package 3 Height 107 cm
Package 3 Width 40 cm
Package 3 Length 60 cm
Package 3 Weight 122.82 kg

Main Document

Data Sheet : C10B6TM063 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10B6TM063 Compact | Circuit breaker, ComPacT NSX100B, 25kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 63A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024