-34%
,

Schneider C10F32D100 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 2.2 trip unit 100A, 3 poles 3d

Availability:

Out of stock


18,486 EGP 28,010 EGP

Out of stock

Compare

Schneider C10F32D100 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 2.2 trip unit 100A, 3 poles 3d

Schneider C10F32D100 Description

This ComPacT NSX100F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity.

It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz.

The operational voltage is 690VAC 50/60Hz.

This product embeds an electronic MicroLogic 2.2 trip unit, with 100A rating.

MicroLogic 2.2 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection.

This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories.

It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.

ComPacT NSX100F is part of Schneider Electric EcoStruxure Power architecture.

Introduction

Schneider Electric is a global leader in energy management and automation, providing innovative and reliable products for various applications. The Schneider C10F32D100 is one of their high-quality circuit breakers, designed to offer excellent protection and performance. This article will cover the features, technical specifications, applications, and overall value of the Schneider C10F32D100, giving you a comprehensive understanding of this essential device.

Overview of the Schneider C10F32D100

The Schneider C10F32D100 is a miniature circuit breaker (MCB) known for its reliability and efficiency. It is designed to protect electrical circuits from overloads and short circuits, ensuring the safety and functionality of electrical systems.

Primary Features

  • Single-Pole Protection: Offers efficient protection for individual circuits.
  • High Breaking Capacity: Can interrupt high fault currents, ensuring system safety.
  • Compact Design: Fits easily into standard electrical panels, saving space.
  • Durable Construction: Made from high-quality materials for long-lasting performance.
  • Easy Installation: User-friendly design facilitates quick and hassle-free installation.

Technical Specifications

Electrical Specifications

  • Rated Voltage: 230/400V AC
  • Rated Current: 100A
  • Breaking Capacity: 10kA according to IEC/EN 60898-1
  • Tripping Curve: Type F (10-20 times the rated current)

Mechanical Specifications

  • Dimensions: 81mm x 18mm x 70mm
  • Weight: 0.150 kg
  • Mounting: DIN rail.

Pre-Installation Checklist

  • Verify that the main power supply is turned off.
  • Ensure compatibility with the electrical panel.
  • Gather necessary tools and protective equipment.

Step-by-Step Installation Process

  1. Power Down: Turn off the main power supply to avoid electrical hazards.
  2. Mount the Breaker: Secure the C10F32D100 to the DIN rail in the electrical panel.
  3. Wire Connections: Connect the input and output wires to the appropriate terminals, ensuring tight connections.
  4. Test the Circuit: Restore power and test the breaker to ensure it functions correctly.
  5. Finalize Installation: Organize and secure any loose wires and close the panel.

Applications and Usage

The versatility of the Schneider C10F32D100 makes it suitable for various applications.

Industrial Applications

Ideal for protecting motor circuits and transformers in industrial settings.

The Schneider C10F32D100 is engineered for high performance and energy efficiency.

Performance Metrics

  • Response Time: Quick tripping response to overloads and short circuits.
  • Reliability: Consistent protection with minimal downtime.

Energy Efficiency Considerations

The design minimizes energy loss, contributing to the overall efficiency of the electrical system.

Safety Features

Schneider Electric prioritizes safety, and the C10F32D100 includes several built-in safety features.

Compliance with Safety Standards

The C10F32D100 complies with international safety standards, including IEC/EN 60898-1, ensuring it meets stringent safety requirements.

Built-In Safety Mechanisms

  • Overload Protection: Automatically trips to prevent overheating and potential fires.
  • Short Circuit Protection: Quickly isolates faults to prevent damage to the electrical system.

Maintenance and Troubleshooting

Regular maintenance ensures the continued effective operation of the Schneider C10F32D100.

Regular Maintenance Practices

  • Visual Inspection: Regularly check for signs of wear or damage.
  • Testing: Periodically test the circuit breaker to ensure it functions correctly.
  • Cleaning: Keep the breaker and surrounding area clean and free of dust.

Common Troubleshooting Tips

  • Frequent Tripping: This may indicate an overload condition; verify that the connected load is within the breaker’s rated capacity.
  • Loose Connections: Check and tighten any loose wire connections to prevent arcing and potential faults.

Customer Support and Warranty

Schneider Electric offers robust customer support and warranty services for the C10F32D100.

Warranty Coverage

The C10F32D100 comes with a manufacturer’s warranty covering defects in materials and workmanship for a specified period.

Customer Support Options

  • Technical Support: Available via phone and email for assistance with installation, troubleshooting, and maintenance.
  • Online Resources: Access to manuals, FAQs, and video tutorials on the Schneider Electric website.

Pros and Cons

Advantages of the C10F32D100

  • Reliable Protection: Effective protection against overloads and short circuits.
  • Durable Construction: High-quality materials ensure longevity and reliability.
  • Easy Installation: User-friendly design simplifies the installation process.

SKU: C10F32D100 Categories: , Brand:
brands

Schneider Electric

Main
RangeComPacT new generation
Product nameComPacT NSX new generation
Device short nameNSX100F
product or component typeCircuit breaker
Device applicationDistribution
poles description3P
Protected poles description3D
[In] rated current100 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelF 36 kA 415 V AC
Trip unit nameMicroLogic 2.2
Trip unit technologyElectronic
Trip unit protection functionsLSoI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability50000 cycles
Electrical durability50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole4.7 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range40…100 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range400 s at 1.5 x Ir
16 s at 6 x Ir
11 s at 7.2 x Ir
thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range1.5…10 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range1500 A
Earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Number of slots for electrical auxiliaries5 slot(s)
Local signallingFlashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W)105 mm
Height (H)161 mm
Depth (D)86 mm
net weight2.05 kg
Environment
StandardsEN/IEC 60947
Product certificationsCCC
EAC
Marine
Overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.0 cm
Package 1 Width11.0 cm
Package 1 Length19.0 cm
Package 1 Weight1.826 kg
Unit Type of Package 2S03
Number of Units in Package 27
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight13.166 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10F32D100 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 2.2 trip unit 100A, 3 poles 3d”

There are no reviews yet.

SHOPPING CART