-34%
,

Schneider C10F3TM032 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 32A, 3 poles 3d

Availability:

In stock


10,925 EGP 16,553 EGP

In stock

Compare

Schneider C10F3TM032 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 32A, 3 poles 3d

Schneider C10F3TM032 Description

This ComPacT NSX100F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity.
It is an optimal choice for all standard and specific applications.
The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz.
This product embeds a 32A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection.
This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories.
It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.
ComPacT NSX100F is part of Schneider Electric EcoStruxure Power architecture.

Introduction

Schneider Electric is a global leader in energy management and automation solutions. Among their extensive range of products are high-quality circuit breakers designed to ensure the safety and efficiency of electrical systems. The Schneider C10F3TM032 is a notable example, offering reliable protection and exceptional performance. This article delves into the features, technical specifications, applications, and overall value of the Schneider C10F3TM032.

Overview of the Schneider C10F3TM032

The Schneider C10F3TM032 is a miniature circuit breaker (MCB) engineered to protect electrical circuits from overloads and short circuits. It plays a crucial role in maintaining the safety and reliability of electrical systems.

Basic Description

The Schneider C10F3TM032 is a single-pole, 32A circuit breaker with an F curve characteristic, meaning it trips between 3 to 5 times the rated current. This makes it suitable for protecting circuits with moderate inrush currents.

Key Features

  • Single-Pole Protection: Provides effective protection for individual circuits.
  • High Breaking Capacity: Can interrupt high fault currents, ensuring system safety.
  • Compact Design: Fits easily into standard electrical panels, saving space.
  • Durable Construction: Made from high-quality materials for long-lasting performance.
  • Easy Installation: User-friendly design for quick and hassle-free installation.

Technical Specifications

Electrical Specifications

  • Rated Voltage: 230/400V AC
  • Rated Current: 32A
  • Breaking Capacity: 10kA according to IEC/EN 60898-1
  • Tripping Curve: Type F (3-5 times the rated current)

Mechanical Specifications

  • Dimensions: 81mm x 18mm x 70mm
  • Weight: 0.150 kg
  • Mounting: DIN rail

Design and Build Quality

The Schneider C10F3TM032 is designed for durability and reliability, featuring high-quality materials and precise construction.

Materials Used

  • Housing: Fire-resistant plastic ensures safety and durability.
  • Internal Components: Constructed from high-grade copper and silver alloy.
  • Terminals: Made from corrosion-resistant metals to ensure longevity.

Construction Details

Schneider Electric ensures that each circuit breaker meets high standards of performance and safety through stringent quality control measures. The C10F3TM032 is designed to withstand regular use in demanding environments, providing reliable protection over the long term.

Installation Guidelines

Proper installation is crucial for the effective performance and safety of the Schneider C10F3TM032.

Pre-Installation Checklist

  • Verify that the main power supply is turned off.
  • Ensure compatibility with the electrical panel.
  • Gather necessary tools and protective equipment.

Step-by-Step Installation Process

  1. Power Down: Turn off the main power supply to avoid electrical hazards.
  2. Mount the Breaker: Secure the C10F3TM032 to the DIN rail in the electrical panel.
  3. Wire Connections: Connect the input and output wires to the appropriate terminals, ensuring tight connections.
  4. Test the Circuit: Restore power and test the breaker to ensure it functions correctly.
  5. Finalize Installation: Organize and secure any loose wires and close the panel.

Applications and Usage

The versatility of the Schneider C10F3TM032 makes it suitable for various applications.

Industrial Applications

Ideal for protecting motor circuits and transformers in industrial settings.

Commercial Applications

Provides reliable protection for lighting, HVAC systems, and other commercial electrical loads.

Residential Applications

Perfect for household electrical circuits, safeguarding appliances and preventing electrical hazards.

Compatibility and Integration

The Schneider C10F3TM032 is designed to integrate seamlessly with various electrical systems.

Compatible Systems and Devices

  • Electrical Panels: Compatible with standard residential, commercial, and industrial electrical panels.
  • Automation Systems: Can be integrated with building automation systems for enhanced control and monitoring.
  • Renewable Energy Systems: Suitable for use in small-scale solar and wind power installations.

Safety Features

Schneider Electric prioritizes safety, and the C10F3TM032 includes several built-in safety features.

Compliance with Safety Standards

The C10F3TM032 complies with international safety standards, including IEC/EN 60898-1, ensuring it meets stringent safety requirements.

Built-In Safety Mechanisms

  • Overload Protection: Automatically trips to prevent overheating and potential fires.
  • Short Circuit Protection: Quickly isolates faults to prevent damage to the electrical system.

Maintenance and Troubleshooting

Regular maintenance ensures the continued effective operation of the Schneider C10F3TM032.

Regular Maintenance Practices

  • Visual Inspection: Regularly check for signs of wear or damage.
  • Testing: Periodically test the circuit breaker to ensure it functions correctly.
  • Cleaning: Keep the breaker and surrounding area clean and free of dust.

Common Troubleshooting Tips

  • Frequent Tripping: This may indicate an overload condition; verify that the connected load is within the breaker’s rated capacity.
  • Loose Connections: Check and tighten any loose wire connections to prevent arcing and potential faults.

Customer Support and Warranty

Schneider Electric offers robust customer support and warranty services for the C10F3TM032.

Warranty Coverage

The C10F3TM032 comes with a manufacturer’s warranty covering defects in materials and workmanship for a specified period.

Customer Support Options

  • Technical Support: Available via phone and email for assistance with installation, troubleshooting, and maintenance.
  • Online Resources: Access to manuals, FAQs, and video tutorials on the Schneider Electric website.

Pros and Cons

Advantages of the C10F3TM032

  • Reliable Protection: Effective protection against overloads and short circuits.
  • Durable Construction: High-quality materials ensure longevity and reliability.
  • Easy Installation: User-friendly design simplifies the installation process.

Potential Limitations

  • Cost: May be more expensive compared to some competitors.
  • Limited Industrial Use: Primarily designed for residential and light commercial use, not heavy industrial applications.
SKU: C10F3TM032 Categories: , Brand:
brands

Schneider Electric

Main
RangeComPacT new generation
Product nameComPacT NSX new generation
Device short nameNSX100F
product or component typeCircuit breaker
Device applicationDistribution
poles description3P
Protected poles description3D
[In] rated current32 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelF 36 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability50000 cycles
Electrical durability50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole4.03 W
mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating32 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range120…400 s at 1.5 x In
15 s at 6 x Ir
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range400 A
Earth-leakage protectionWithout
Number of slots for electrical auxiliaries5 slot(s)
Width (W)105 mm
Height (H)161 mm
Depth (D)86 mm
net weight2.05 kg
Environment
StandardsEN/IEC 60947
Product certificationsCCC
EAC
Marine
Overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.0 cm
Package 1 Width11.0 cm
Package 1 Length19.0 cm
Package 1 Weight1.818 kg
Unit Type of Package 2S03
Number of Units in Package 27
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight13.11 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10F3TM032 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 32A, 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat