Schneider C10F3TM040 Description

This ComPacT NSX100F is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity.

It is an optimal choice for all standard and specific applications.

The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz.

The operational voltage is 690VAC 50/60Hz. This product embeds a 40A rating thermal-magnetic trip unit (TMD).

TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection.

This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories.

It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.

ComPacT NSX100F is part of Schneider Electric EcoStruxure Power architecture.

Schneider C10F3TM040 Description

Introduction

Schneider Electric is a global leader in energy management and automation solutions. Among their extensive range of products are high-quality circuit breakers designed to ensure the safety and efficiency of electrical systems. The Schneider C10F3TM040 is a notable example, offering reliable protection and exceptional performance. This article delves into the features, technical specifications, applications, and overall value of the Schneider C10F3TM040.

Overview of the Schneider C10F3TM040

The Schneider C10F3TM040 is a miniature circuit breaker (MCB) engineered to protect electrical circuits from overloads and short circuits. It plays a crucial role in maintaining the safety and reliability of electrical systems.

Basic Description

The Schneider C10F3TM040 is a single-pole, 40A circuit breaker with an F curve characteristic, meaning it trips between 3 to 5 times the rated current. This makes it suitable for protecting circuits with moderate inrush currents.

Key Features

  • Single-Pole Protection: Provides effective protection for individual circuits.
  • High Breaking Capacity: Can interrupt high fault currents, ensuring system safety.
  • Compact Design: Fits easily into standard electrical panels, saving space.
  • Durable Construction: Made from high-quality materials for long-lasting performance.
  • Easy Installation: User-friendly design for quick and hassle-free installation.

Construction Details

Schneider Electric ensures that each circuit breaker meets high standards of performance and safety through stringent quality control measures. The C10F3TM040 is designed to withstand regular use in demanding environments, providing reliable protection over the long term.

Installation Guidelines

Proper installation is crucial for the effective performance and safety of the Schneider C10F3TM040.

Pre-Installation Checklist

  • Verify that the main power supply is turned off.
  • Ensure compatibility with the electrical panel.
  • Gather necessary tools and protective equipment.

Step-by-Step Installation Process

  1. Power Down: Turn off the main power supply to avoid electrical hazards.
  2. Mount the Breaker: Secure the C10F3TM040 to the DIN rail in the electrical panel.
  3. Wire Connections: Connect the input and output wires to the appropriate terminals, ensuring tight connections.
  4. Test the Circuit: Restore power and test the breaker to ensure it functions correctly.
  5. Finalize Installation: Organize and secure any loose wires and close the panel.

Applications and Usage

The versatility of the Schneider C10F3TM040 makes it suitable for various applications.

Industrial Applications

Ideal for protecting motor circuits and transformers in industrial settings.

Commercial Applications

Provides reliable protection for lighting, HVAC systems, and other commercial electrical loads.

Residential Applications

Perfect for household electrical circuits, safeguarding appliances and preventing electrical hazards.

Compatibility and Integration

The Schneider C10F3TM040 is designed to integrate seamlessly with various electrical systems.

Compatible Systems and Devices

  • Electrical Panels: Compatible with standard residential, commercial, and industrial electrical panels.
  • Automation Systems: Can be integrated with building automation systems for enhanced control and monitoring.
  • Renewable Energy Systems: Suitable for use in small-scale solar and wind power installations.

Performance Metrics

  • Response Time: Quick tripping response to overloads and short circuits.
  • Reliability: Consistent protection with minimal downtime.

Energy Efficiency Considerations

The design minimizes energy loss, contributing to the overall efficiency of the electrical system.

Customer Support Options

  • Technical Support: Available via phone and email for assistance with installation, troubleshooting, and maintenance.
  • Online Resources: Access to manuals, FAQs, and video tutorials on the Schneider Electric website.

Pros and Cons

Advantages of the C10F3TM040

  • Reliable Protection: Effective protection against overloads and short circuits.
  • Durable Construction: High-quality materials ensure longevity and reliability.
  • Easy Installation: User-friendly design simplifies the installation process.

Potential Limitations

  • Cost: May be more expensive compared to some competitors.
  • Limited Industrial Use: Primarily designed for residential and light commercial use, not heavy industrial applications.
SKU: C10F3TM040 Categories: ,
brands

Schneider Electric

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100F
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 40 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole 5.47 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 40 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 500 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.05 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.0 cm
Package 1 Width 11.0 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.818 kg
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 13.104 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10F3TM040 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 40A, 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024