Schneider C10F42D100 Description

This ComPacT NSX100F is a complete 4P 4d fixed circuit breaker designed to optimize space and breaking capacity.

It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz.

The operational voltage is 690VAC 50/60Hz.

This product embeds an electronic MicroLogic 2.2 trip unit, with 100A rating.

MicroLogic 2.2 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection.

This 4 poles version (140mm x 161mm x 86mm) comes with a variety of optional functions and accessories.

It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.

ComPacT NSX100F is part of Schneider Electric EcoStruxure Power architecture.

Introduction

Schneider Electric is a global leader in energy management and automation. The Schneider C10F42D100 is a high-performance circuit breaker designed to offer robust protection for electrical circuits, ensuring safety and reliability in a wide range of applications.

Design and Build Quality

Schneider Electric ensures all its products, including the C10F42D100, adhere to high standards of safety and durability.

Materials Used

  • Housing: Made from fire-resistant, high-strength plastic to ensure safety and longevity.
  • Internal Components: Utilizes premium metals such as copper and silver alloy for excellent conductivity and durability.
  • Terminals: Corrosion-resistant terminals to maintain reliable connections over time.

Construction Details

  • Robust Construction: Built to withstand mechanical stress and challenging operating conditions.
  • High-Precision Manufacturing: Ensures consistent performance and reliability.

Installation Guidelines

Proper installation of the Schneider C10F42D100 is crucial to ensure optimal performance and safety.

Pre-Installation Checklist

  • Verify that the main power supply is turned off.
  • Ensure the circuit breaker is compatible with the electrical panel and application.
  • Gather all necessary tools and safety equipment.

Step-by-Step Installation Process

  1. Turn Off Power: Ensure the main power supply is completely shut off.
  2. Mount the Breaker: Secure the C10F42D100 onto the DIN rail or surface mount as required.
  3. Connect Wiring: Attach the input and output wires to the appropriate terminals, ensuring secure connections.
  4. Test the Circuit: Restore power and test the breaker to ensure it functions correctly.
  5. Complete Installation: Organize and secure any loose wires and close the panel.

Applications and Usage

The Schneider C10F42D100 is suitable for a variety of applications, providing reliable protection in different environments.

Industrial Applications

  • Protects motor circuits, transformers, and other industrial equipment from electrical faults.

Commercial Applications

  • Ensures the safety of electrical systems in commercial buildings, such as offices and retail spaces.

Residential Applications

  • Provides reliable protection for household electrical circuits, safeguarding appliances and other devices.

Compatibility and Integration

The Schneider C10F42D100 is designed for easy integration with various electrical systems.

Compatible Systems and Devices

  • Electrical Panels: Suitable for installation in standard residential, commercial, and industrial panels.
  • Automation Systems: Can be integrated with building automation systems for enhanced control and monitoring.

Integration Tips

  • Ensure all connections are secure and properly insulated.
  • Regularly inspect and maintain the circuit breaker to ensure ongoing compatibility and performance.

Performance and Efficiency

The Schneider C10F42D100 is designed to deliver high performance and energy efficiency.

Performance Metrics

  • Fast Response Time: Quickly disconnects the circuit in the event of an overload or short circuit.
  • High Reliability: Consistent performance with minimal downtime.

Energy Efficiency Considerations

  • Low Energy Loss: Efficient design minimizes energy loss, contributing to overall system efficiency.

Safety Features

Safety is a top priority for Schneider Electric, and the C10F42D100 is equipped with multiple safety features.

Compliance with Safety Standards

  • Meets international safety standards, ensuring reliable protection and peace of mind.

Built-In Safety Mechanisms

  • Overload Protection: Automatically trips to prevent overheating and potential fire hazards.
  • Short Circuit Protection: Quickly isolates faults to protect the electrical system.
  • Fire-Resistant Housing: Adds an extra layer of protection against electrical fires.

Maintenance and Troubleshooting

Regular maintenance is essential to ensure the continued reliable operation of the Schneider C10F42D100.

Regular Maintenance Practices

  • Visual Inspections: Regularly check for signs of wear, damage, or overheating.
  • Functional Testing: Periodically test the breaker to ensure it operates correctly.
  • Cleaning: Keep the breaker and surrounding area free from dust and debris.

Common Troubleshooting Tips

  • Frequent Tripping: Check for overload conditions or potential short circuits; verify that the connected load is within the breaker’s rated capacity.
  • Loose Connections: Inspect and tighten any loose wire connections to prevent arcing and faults.

Customer Support and Warranty

Schneider Electric offers robust customer support and warranty services for the C10F42D100.

Warranty Coverage

  • Manufacturer’s Warranty: Covers defects in materials and workmanship for a specified period, providing peace of mind.

Customer Support Options

  • Technical Support: Available via phone and email for installation, troubleshooting, and maintenance assistance.
  • Online Resources: Access manuals, FAQs, and video tutorials on the Schneider Electric website.

Pros and Cons

Advantages of the C10F42D100

  • Reliable Protection: Effective protection against overloads and short circuits.
  • Durable Construction: Made with high-quality materials for long-term reliability.
  • Compact and Lightweight: Easy to install in various electrical panels.
SKU: C10F42D100 Categories: ,
brands

Schneider Electric

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100F
product or component type Circuit breaker
Device application Distribution
poles description 4P
Protected poles description 4D
3D + N/2
3D
Neutral position Left
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Trip unit protection functions LSoI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole 4.7 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40…100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 400 s at 1.5 x Ir
16 s at 6 x Ir
11 s at 7.2 x Ir
Neutral protection settings 0.5 x Ir (3D + N/2)
1 x Ir (4D)
No protection (3D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5…10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Number of slots for electrical auxiliaries 5 slot(s)
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.4 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.000 cm
Package 1 Width 15.000 cm
Package 1 Length 19.500 cm
Package 1 Weight 2.384 kg
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 14.696 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10F42D100 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 2.2 trip unit 100A, 4 poles 4d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024