Schneider Electric is a global leader in energy management and automation, providing innovative solutions to enhance efficiency and safety. The Schneider C10F6TM025 is a high-quality circuit breaker designed to protect electrical circuits from overloads and short circuits, ensuring safety and reliability in various applications.

Overview of the Schneider C10F6TM025

The Schneider C10F6TM025 is a miniature circuit breaker (MCB) that automatically disconnects electrical circuits during fault conditions, such as overloads or short circuits, to prevent damage and ensure safety.

Basic Description

  • Product Type: Miniature Circuit Breaker (MCB)
  • Model Number: C10F6TM025
  • Pole: 1P (single pole)
  • Current Rating: 25A

Key Features

  • High Breaking Capacity: Capable of handling significant load variations, making it suitable for a wide range of applications.
  • Compact Design: Optimized for space-saving installation in standard electrical panels.
  • Durable Construction: Manufactured with high-quality materials to ensure long-lasting performance.
  • Easy Installation: Designed for user-friendly mounting and connection.

Technical Specifications

Electrical Specifications

  • Rated Current: 25A
  • Number of Poles: 1
  • Breaking Capacity: High breaking capacity to effectively protect against overloads and short circuits.
  • Operating Voltage: Suitable for both low and medium voltage applications.

Mechanical Specifications

  • Dimensions: Standard size for easy integration into existing systems.
  • Weight: Lightweight yet robust construction for straightforward handling and installation.
  • Mounting Type: Can be mounted on DIN rails or surface-mounted, providing flexibility in installation.

Design and Build Quality

Schneider Electric ensures all its products, including the C10F6TM025, adhere to high standards of safety and durability.

Materials Used

  • Housing: Fire-resistant, high-strength plastic to ensure safety and longevity.
  • Internal Components: High-quality metals like copper and silver alloy for excellent conductivity and durability.
  • Terminals: Corrosion-resistant terminals to maintain reliable connections over time.

Construction Details

  • Robust Construction: Built to withstand mechanical stress and challenging operating conditions.
  • High-Precision Manufacturing: Ensures consistent performance and reliability.

Installation Guidelines

Proper installation of the Schneider C10F6TM025 is crucial to ensure optimal performance and safety.

Pre-Installation Checklist

  • Verify that the main power supply is turned off.
  • Ensure the circuit breaker is compatible with the electrical panel and application.
  • Gather all necessary tools and safety equipment.

Step-by-Step Installation Process

  1. Turn Off Power: Ensure the main power supply is completely shut off.
  2. Mount the Breaker: Secure the C10F6TM025 onto the DIN rail or surface mount as required.
  3. Connect Wiring: Attach the input and output wires to the appropriate terminals, ensuring secure connections.
  4. Test the Circuit: Restore power and test the breaker to ensure it functions correctly.
  5. Complete Installation: Organize and secure any loose wires and close the panel.

Built-In Safety Mechanisms

  • Overload Protection: Automatically trips to prevent overheating and potential fire hazards.
  • Short Circuit Protection: Quickly isolates faults to protect the electrical system.
  • Fire-Resistant Housing: Adds an extra layer of protection against electrical fires.
SKU: C10F6TM025 Categories: , Brand:
Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100F
Product or component type Circuit breaker
Device application Distribution
Poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 25 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole 4.01 W
Mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
Downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 25 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 300 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.4 kg
Environment
Standards EN/IEC 60947-2
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14 cm
Package 1 Width 15 cm
Package 1 Length 19 cm
Package 1 Weight 2.79 kg
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 16.74 kg
Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100F
Product or component type Circuit breaker
Device application Distribution
Poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 25 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Power dissipation per pole 4.01 W
Mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
Downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rating 25 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In 15 s at 6 x Ir
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 300 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.4 kg
Environment
Standards EN/IEC 60947-2
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating 2000 m...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14 cm
Package 1 Width 15 cm
Package 1 Length 19 cm
Package 1 Weight 2.79 kg
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 16.74 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10F6TM025 | Circuit breaker, ComPacT NSX100F, 36kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 25A”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024