Technical Specifications

Electrical Specifications

  • Rated Current: 32A
  • Number of Poles: 1
  • Breaking Capacity: High breaking capacity to protect against overloads and short circuits.
  • Operating Voltage: Suitable for both low and medium voltage applications.

Mechanical Specifications

  • Dimensions: Standard size for easy integration into existing systems.
  • Weight: Lightweight construction for straightforward handling and installation.
  • Mounting Type: Can be mounted on DIN rails or surface-mounted.

Design and Build Quality

Schneider Electric ensures that the C10F6TM032 meets high standards of safety and durability.

Materials Used

  • Housing: Fire-resistant, high-strength plastic to ensure safety and longevity.
  • Internal Components: High-quality metals such as copper and silver alloy for excellent conductivity and durability.
  • Terminals: Corrosion-resistant terminals for reliable long-term connections.

Construction Details

  • Robust Construction: Built to withstand mechanical stress and challenging operating conditions.
  • High-Precision Manufacturing: Ensures consistent performance and reliability.
  1. Compatible Systems and Devices
  • Electrical Panels: Suitable for installation in standard residential, commercial, and industrial panels.
  • Automation Systems: Can be integrated with building automation systems for enhanced control and monitoring.

Integration Tips

  • Ensure all connections are secure and properly insulated.
  • Regularly inspect and maintain the circuit breaker to ensure ongoing compatibility and performance.

Built-In Safety Mechanisms

  • Overload Protection: Automatically trips to prevent overheating and potential fire hazards.
  • Short Circuit Protection: Quickly isolates faults to protect the electrical system.
  • Fire-Resistant Housing: Adds an extra layer of protection against electrical fires.

Maintenance and Troubleshooting

Regular maintenance is essential to ensure the continued reliable operation of the Schneider C10F6TM032.

Regular Maintenance Practices

  • Visual Inspections: Regularly check for signs of wear, damage, or overheating.
  • Functional Testing: Periodically test the breaker to ensure it operates correctly.
  • Cleaning: Keep the breaker and surrounding area free from dust and debris.

Comparison with Similar Products

When compared to similar products, the Schneider C10F6TM032 stands out for its performance and reliability.

SKU: C10F6TM032 Categories: , Brand:
Main
RangeComPacT new generation
Product nameComPacT NSX new generation
Device short nameNSX100F
Product or component typeCircuit breaker
Device applicationDistribution
Poles description4P
Protected poles description3D
Neutral positionLeft
[In] rated current32 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelF 36 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
Control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability50000 cycles
Electrical durability50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole4.03 W
Mounting supportBackplate
Mounting positionHorizontal and vertical
Flat on the back
Upside connectionFront
Downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating32 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range120…400 s at 1.5 x In
15 s at 6 x Ir
Neutral protection settingsNo protection (3D)
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range400 A
Earth-leakage protectionWithout
Number of slots for electrical auxiliaries5 slot(s)
Width (W)140 mm
Height (H)161 mm
Depth (D)86 mm
Net weight2.4 kg
Environment
StandardsEN/IEC 60947-2
Overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14 cm
Package 1 Width15 cm
Package 1 Length19 cm
Package 1 Weight2.79 kg
Unit Type of Package 2S03
Number of Units in Package 26
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight16.74 kg

Main Document

Data Sheet : C10F6TM032

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10F6TM032 | Circuit breaker, ComPacT NSX100F, 36kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 32A”

There are no reviews yet.

SHOPPING CART

close
Let's Chat