Schneider C10N32D100 | Circuit breaker ComPacT NSX100N, 50kA at 415VAC, MicroLogic 2.2 trip unit 100A, 3 poles 3d

Schneider Electric
Availability:

Out of stock


19,216.30 EGP 29,115.60 EGP

Out of stock

Schneider C10N32D100 | Circuit breaker ComPacT NSX100N, 50kA at 415VAC, MicroLogic 2.2 trip unit 100A, 3 poles 3d

Schneider C10N32D100 Description

This ComPacT NSX100N is a complete 3P 3d fixed circuit breaker designed to optimize space and breaking capacity.

It is an optimal choice for all standard and specific applications.

The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz.

This product embeds an electronic MicroLogic 2.2 trip unit, with 100A rating.

MicroLogic 2.2 trip unit provides adjustable long time and short time protections, and a fixed instantaneous protection.

This 3 poles version (105mm x 161mm x 86mm) comes with a variety of optional functions and accessories.

It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.

ComPacT NSX100N is part of Schneider Electric EcoStruxure Power architecture.

Introduction

When it comes to electrical components, choosing the right product can significantly impact the efficiency and safety of your electrical systems. Schneider Electric, a leader in energy management and automation, offers a wide range of high-quality products designed to meet diverse needs. Among these is the Schneider C10N32D100, a reliable and efficient circuit breaker. This article provides an in-depth look at the Schneider C10N32D100, highlighting its features, applications, and benefits.

Understanding Schneider C10N32D100

Basic Description

The Schneider C10N32D100 is a compact and versatile circuit breaker designed to provide reliable protection for electrical circuits. This product is part of Schneider Electric’s extensive portfolio, known for its durability and performance in various applications.

Key Features

  • Compact Design: Space-saving design suitable for a variety of installations.
  • High Breaking Capacity: Can handle high fault currents, providing robust protection.
  • Easy Installation: Designed for quick and straightforward installation.
  • Enhanced Safety: Includes advanced safety features to prevent electrical hazards.

Technical Specifications

  • Voltage Rating: 415V
  • Current Rating: 100A
  • Breaking Capacity: High fault current rating for enhanced protection
  • Poles: Triple-pole configuration
  • Compliance: Meets international standards for safety and performance

Applications of Schneider C10N32D100

Industrial Uses

In industrial applications, the Schneider C10N32D100 is well-suited for protecting circuits in factories, manufacturing plants, and other industrial facilities. Its durable design and high performance make it a reliable choice for demanding environments.

Installation and Maintenance

Installation Guide

Installing the Schneider C10N32D100 is straightforward, making it accessible for both professional electricians and knowledgeable DIY enthusiasts. Here’s a brief guide:

  1. Turn Off Power: Ensure the power supply is turned off before beginning installation.
  2. Prepare the Installation Area: Verify that the area is safe and ready for installation.
  3. Connect the Wires: Follow the wiring diagram provided with the product.
  4. Mount the Circuit Breaker: Secure the Schneider C10N32D100 in place.
  5. Test the Installation: Restore power and test the circuit breaker to ensure proper functionality.

Maintenance Tips

  • Regular Inspections: Periodically inspect the circuit breaker for any signs of wear or damage.
  • Clean Regularly: Keep the breaker free from dust and debris to ensure optimal performance.
  • Professional Servicing: Consult a professional for any repairs or if you encounter issues beyond basic troubleshooting.

Advantages of Schneider C10N32D100

Reliability

The Schneider C10N32D100 is known for its reliability, providing consistent protection for electrical circuits. Its robust design ensures long-term performance, making it a dependable choice for various applications.

Efficiency

Designed for efficiency, the Schneider C10N32D100 helps optimize energy use and reduce waste. This efficiency translates to cost savings and a reduced environmental footprint.

Safety

Safety is a top priority with Schneider Electric products. The C10N32D100 includes advanced safety features to protect against overloads, short circuits, and other electrical hazards, ensuring peace of mind for users.

Comparing Schneider C10N32D100 with Other Models

Schneider C10N32D100 vs. Competitors

When compared to similar products from other manufacturers, the Schneider C10N32D100 stands out for its high breaking capacity, compact design, and advanced safety features. While other models may offer similar specifications, Schneider Electric’s commitment to quality and innovation provides an added advantage.

Cost-Benefit Analysis

Although the initial cost of the Schneider C10N32D100 may be higher than some competitors, its durability, efficiency, and safety features offer significant long-term value. Reduced maintenance and replacement costs make it a cost-effective choice over time.

Customer Reviews and Feedback

Common Praises

  • Durable Construction: Customers often highlight the product’s robust and durable build.
  • Ease of Installation: Many users appreciate the straightforward installation process.
  • Reliable Performance: Consistent and reliable performance is a common praise in customer reviews.

Common Complaints

  • Higher Initial Cost: Some customers note the higher upfront cost compared to other brands.
  • Limited Availability: Occasionally, users report difficulty in finding the product locally.
SKU: C10N32D100 Categories: , Brand:
brands

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100N
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Trip unit protection functions LSoI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole 4.7 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
I : for instantaneous short-circuit protection
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40…100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 400 s at 1.5 x Ir
16 s at 6 x Ir
11 s at 7.2 x Ir
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5…10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Number of slots for electrical auxiliaries 5 slot(s)
Local signalling Flashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.05 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.0 cm
Package 1 Width 11.0 cm
Package 1 Length 19.2 cm
Package 1 Weight 1.833 kg
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 13.206 kg
Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100N
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name MicroLogic 2.2
Trip unit technology Electronic
Trip unit protection functions LSoI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Power dissipation per pole 4.7 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
Earth-leakage protection Without
Zone selective interlocking ZSI Without
Number of slots for electrical auxiliaries 5 slot(s)
Local signalling Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.05 kg
Environment
Standards EN/IEC 60947
Product certifications CCC EAC Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating 2000 m...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.0 cm
Package 1 Width 11.0 cm
Package 1 Length 19.2 cm
Package 1 Weight 1.833 kg
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 13.206 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10N32D100 | Circuit breaker ComPacT NSX100N, 50kA at 415VAC, MicroLogic 2.2 trip unit 100A, 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024