Introduction

it is a critical component in contemporary electrical systems, renowned for its reliability and efficiency. This article explores the features, benefits, and applications of the Schneider C10N6TM063 Compact, demonstrating why it is a preferred choice for a wide range of electrical installations.

Understanding the Schneider C10N6TM063 Compact

Definition and Purpose

it is a circuit breaker designed to protect electrical circuits from overloads, short circuits, and other faults. Its primary purpose is to ensure the safety and reliability of electrical systems, protecting equipment and personnel from potential hazards.

Key Features and Specifications

Key features of the Schneider C10N6TM063 Compact include:

  • High Breaking Capacity: Capable of interrupting high fault currents.
  • Compact Design: Space-saving without compromising performance.
  • Adjustable Protection Settings: Customizable to meet specific requirements.
  • Ease of Installation: User-friendly design simplifies setup.
  • Durable Construction: Built to withstand various environmental demands.

Benefits of Using Schneider C10N6TM063 Compact

Enhanced Safety Measures

Safety is a top priority in electrical systems, and it excels in this regard with its advanced protection mechanisms. It quickly detects and responds to faults, reducing the risk of electrical hazards and ensuring the safety of both personnel and equipment.

Reliability and Durability

it is designed for long-term use, offering durable construction and reliable performance. It can endure the rigors of various applications, providing consistent protection and peace of mind to users.

Energy Efficiency

In an era focused on energy conservation, it stands out for its energy efficiency. It optimizes energy use, helping to reduce waste and lower electricity bills, contributing to overall energy conservation efforts.

Applications of Schneider C10N6TM063 Compact

Industrial Settings

In industrial environments, where electrical loads can be substantial and complex, the Schneider C10N6TM063 Compact offers reliable protection and efficient energy management. It is ideal for machinery, equipment, and production lines, ensuring uninterrupted operations.

Commercial Installations

Commercial buildings, such as offices, malls, and hotels, benefit from the Schneider C10N6TM063 Compact’s compact design and advanced protection features. It helps maintain the integrity of electrical systems, supporting business continuity and protecting valuable assets.

Residential Use

Even in residential settings, the Schneider C10N6TM063 Compact proves invaluable. Its high breaking capacity and customizable settings make it suitable for protecting household electrical systems, providing peace of mind to homeowners.

Installation Process

Pre-installation Preparations

Before installing the Schneider C10N6TM063 Compact, it is essential to conduct a thorough assessment of the electrical system. Ensure that all necessary tools and materials are available, and safety protocols are followed.

Step-by-Step Installation Guide

  1. Turn Off Power: Disconnect the main power supply to prevent accidents.
  2. Mount the Circuit Breaker: Secure the Schneider C10N6TM063 Compact in its designated location, following the manufacturer’s instructions.
  3. Connect Wiring: Wire the circuit breaker according to the provided diagram, ensuring proper connections.
  4. Adjust Settings: Customize the protection settings as per the requirements of the electrical system.
  5. Test the Installation: Conduct thorough testing to ensure the circuit breaker is functioning correctly.
  6. Restore Power: Once the installation is verified, restore the power supply and monitor for any abnormalities.

Maintenance Tips

Regular Checks

Regular maintenance is essential to ensure the optimal performance of the Schneider C10N6TM063 Compact. Conduct routine checks to inspect for loose connections, signs of wear, or any other issues that may arise.

Troubleshooting Common Issues

If any issues are detected, refer to the troubleshooting guide provided by Schneider Electric. Common problems can often be resolved by adjusting settings or replacing faulty components.

Comparison with Competitors

Performance Evaluation

When compared to competitors, the Schneider C10N6TM063 Compact excels in terms of performance, offering reliable protection and efficient operation. Its high breaking capacity and advanced features set it apart from similar products on the market.

Cost Analysis

While the initial cost of the Schneider C10N6TM063 Compact may be higher than some alternatives, its long-term durability and reliability often result in cost savings. Reduced maintenance needs and enhanced safety contribute to its overall value.

SKU: C10N6TM063 Categories: ,
Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100N
Product or component type Circuit breaker
Device application Distribution
Poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 63 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2
30000 cycles at 440 V In
20000 cycles at 690 V In/2
10000 cycles at 690 V In
Power dissipation per pole 8.61 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 63 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 500 A
earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 140 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.4 kg
Environment
Standards EN/IEC 60947
product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.0 cm
Package 1 Width 18.0 cm
Package 1 Length 19.0 cm
Package 1 Weight 2.301 kg
Unit Type of Package 2 S03
Number of Units in Package 2 4
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 9.645 kg

Main Document

Data Sheet : C10N6TM063 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C10N6TM063 Compact | Circuit breaker, ComPacT NSX100N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 63A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024