Let's Chat
-36%

Schneider C11E44V050L | Circuit breaker ComPacT NSXm E (16kA at 415VAC), 4 Poles 4d, 50A rating Micrologic 4.1 trip unit, connectors

Schneider Electric
Availability:

Out of stock


33,744 EGP 52,725 EGP

Out of stock

Compare

Schneider C11E44V050L | Circuit breaker ComPacT NSXm E (16kA at 415VAC), 4 Poles 4d, 50A rating Micrologic 4.1 trip unit, connectors

Schneider C11E44V050L Description:

ComPacT NSXm100E is a complete 4P fixed circuit breaker designed to optimize space and breaking capacity.

The breaking capacity (Icu) is 16kA rms at 415VAC 50/60Hz. The operational voltage is 440VAC 50/60Hz.

It introduces new features like Everlink connectors technology.

It offers built-in DIN rail & plate mounting capability and spring type auxiliaries externally visible.

This 4 poles Earth Leakage Circuit Breaker (ELCB) is one of the smallest on the market.

The dimensions are 108mm (W) x 144mm (H) x 80mm (D). It ensures compliance with international standards (IEC 60947/CCC/EAC) and marine specifications.

Product Overview: The Schneider C11E44V050L surge protector is designed to protect electrical systems and equipment from transient overvoltages caused by lightning strikes, electrical switching, and other voltage spikes. It provides reliable protection to ensure the safety and longevity of connected devices.

Key Features (Typical for Schneider Surge Protectors):

  1. Type 2 Surge Protection: Typically installed at distribution boards to protect against indirect lightning strikes and switching surges.
  2. High Surge Current Capacity: Offers a robust discharge capacity to divert excess voltage away from sensitive equipment, preventing damage.
  3. Visual Indication: Equipped with status LEDs for clear indication of operational status and potential fault conditions.
  4. Modular and Compact Design: Designed for easy installation in various electrical panels and enclosures, providing flexibility in deployment and maintenance.
  5. Compliance: Meets international standards and certifications for surge protection devices, ensuring reliability and safety in operation.

Applications:

  • Industrial: Protects machinery, control systems, and other critical equipment in industrial environments where voltage surges can disrupt operations.
  • Commercial: Safeguards sensitive electronic devices in offices, retail spaces, and other commercial buildings.
  • Residential: Ensures household appliances and electronics are shielded from electrical surges.

Installation: Typically installed at main distribution boards or sub-distribution boards to protect downstream equipment from transient overvoltages.

Technical Specifications (Typical):

  • Nominal Voltage: 230V AC
  • Maximum Continuous Operating Voltage: 275V AC
  • Nominal Discharge Current (In): Typically around 40 kA
  • Total Nominal Discharge Current (It): 50 kA
  • Protection Modes: L-N, L-PE, N-PE

Manufacturer: Schneider Electric, a leading global provider of energy management and automation solutions.

For precise technical details and additional features specific to the Schneider C11E44V050L surge protector, consulting Schneider Electric’s official documentation or contacting their customer support would provide accurate and detailed information tailored to your requirements.

SKU: C11E44V050L Category:
brands

Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 63E
product or component type Earth leakage circuit breaker
Device application Distribution
poles description 4P
Protected poles description 4D
Neutral position Left
[In] rated current 50 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
16 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Performance level E 16 kA 415 V AC
Trip unit name MicroLogic 4.1
Trip unit technology Electronic
Trip unit protection functions LSoIR
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 25 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
16 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 1.88 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…70 mm², fine stranded copper
1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 12 module
Trip unit rating 50 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 20…50 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 200 s at 1.5 x Ir
8 s at 6 x Ir
5 s at 7.2 x Ir
Neutral protection settings 1 x Ir (4D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5…10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 750 A
Earth-leakage protection Integrated
Earth-leakage protection class Class A
Class AC
Earth-leakage protection sensitity adjustment type IΔn Adjustable
[IΔn] earth-leakage protection sensitivity adjustment range 30 mA
100 mA
300 mA
500 mA
1 A
3 A
5 A
Earth-leakage sensitivity 30 mA for class A
100 mA for class A
300 mA for class A
500 mA for class A
1 A for class A
30 mA for class AC
100 mA for class AC
300 mA for class AC
500 mA for class AC
1 A for class AC
3 A for class AC
5 A for class AC
Earth-leakage protection time delay adjustement type Δt Adjustable
[Δt] Earth-leakage protection time delay adjustment range 0 ms
60 ms
150 ms
500 ms
1000 ms
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 108 mm
Height (H) 144 mm
Depth (D) 80 mm
net weight 1.63 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.0 cm
Package 1 Width 13.0 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.783 kg
Unit Type of Package 2 S03
Number of Units in Package 2 4
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.5 kg

Main Document

Data Sheet : C11E44V050L

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11E44V050L | Circuit breaker ComPacT NSXm E (16kA at 415VAC), 4 Poles 4d, 50A rating Micrologic 4.1 trip unit, connectors”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024