Schneider C11E6TM050L: Comprehensive Guide and Benefits

Introduction

it is a cutting-edge electrical component renowned for its reliability and efficiency across various applications. Understanding its features and capabilities is essential for optimizing your electrical systems. Let’s delve into what makes the Schneider C11E6TM050L a standout choice in industrial and residential settings.

What is the Schneider C11E6TM050L?

it represents a pinnacle in electrical engineering, designed to enhance power distribution and management with precision and durability. This section provides an overview of its specifications and functionalities.

Design and Build Quality

Crafted from premium materials, it excels in durability and performance longevity. Its robust design ensures resilience in demanding environments, reflecting Schneider’s commitment to quality and reliability.

Technical Specifications

The Schneider C11E6TM050L boasts impressive technical specifications:

  • Electrical Specifications: Includes voltage ratings, current capacity, and insulation levels.
  • Mechanical Specifications: Details on dimensions, weight, and mounting options.

These specifications ensure optimal performance and safety compliance, meeting the stringent requirements of industrial and residential installations.

Installation and Setup

Installing the Schneider C11E6TM050L requires meticulous attention to detail to guarantee efficiency and safety. Here’s a concise installation guide:

  1. Preparation: Gather necessary tools and safety gear.
  2. Location: Select an appropriate mounting position.
  3. Wiring: Follow manufacturer-provided diagrams and instructions.
  4. Testing: Conduct thorough testing to validate functionality before finalizing installation.

Adhering to these steps minimizes risks and ensures seamless integration into your electrical system.

Applications of Schneider C11E6TM050L

The versatility of the Schneider C11E6TM050L extends across diverse applications:

  • Industrial Uses: Essential in control panels, automation systems, and machinery.
  • Residential Applications: Optimizes power distribution and management in homes.

Its adaptability makes it an indispensable asset, enhancing operational efficiency and reliability in various electrical setups.

Performance and Efficiency

A standout feature of it is its exceptional energy efficiency. It maximizes power usage efficiency without compromising performance, resulting in reduced operational costs over time. Its operational efficiency contributes to sustainable energy practices, aligning with modern environmental standards.

Compatibility and Integration

it integrates seamlessly with existing systems and devices, facilitating enhanced functionality and operational synergy. It supports interoperability across diverse platforms, ensuring ease of integration without extensive modifications. This compatibility underscores its versatility and utility in diverse electrical environments.

Advantages of Using Schneider C11E6TM050L

Using the Schneider C11E6TM050L offers several advantages:

  • Reliability: Consistent performance in demanding conditions.
  • Efficiency: Optimizes energy consumption for cost-effective operation.
  • Durability: Ensures long-term reliability and operational longevity.
  • Versatility: Suitable for various industrial and residential applications.

Compared to competitors, it excels in delivering superior performance and cost-efficiency.

Maintenance and Troubleshooting

Regular maintenance enhances the lifespan and efficiency of the Schneider C11E6TM050L:

  • Inspections: Periodic checks for wear and tear.
  • Cleaning: Maintain cleanliness around the device.
  • Servicing: Schedule professional servicing as recommended.

For troubleshooting, refer to manufacturer guidelines to promptly address common issues and ensure uninterrupted operation.

Cost and Availability

it is competitively priced, considering its advanced features and benefits. It is readily available through authorized distributors, online retailers, and local electrical supply stores. Comparison shopping ensures you find the best deals and service options tailored to your specific requirements.

SKU: C11E6TM050L Category:
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 63E
product or component type Circuit breaker
Device application Distribution
poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 50 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
16 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Performance level E 16 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 25 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
16 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 4.81 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
1 Everlink lug wire size 2.5…70 mm², flexible copper
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 12 module
Trip unit rating 50 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 600 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 108 mm
Height (H) 137 mm
Depth (D) 80 mm
net weight 1.42 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 13 cm
Package 1 Width 12 cm
Package 1 Length 22 cm
Package 1 Weight 1.6 kg
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 10.19 kg
Unit Type of Package 3 P12
Number of Units in Package 3 144
Package 3 Height 150 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 254.49 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11E6TM050L | Circuit breaker, ComPacT NSXm 63E, 16kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 50A,”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024