Let's Chat
-36%

Schneider C11E6TM080B | Circuit breaker, ComPacT NSXm 160E, 16kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 80A

Schneider Electric
Availability:

Out of stock


Schneider C11E6TM080B | Circuit breaker, ComPacT NSXm 160E, 16kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 80A

10,849 EGP 16,952 EGP

Out of stock

Compare

Schneider C11E6TM080B: The Ultimate Electrical Component

Introduction

it is a premier product in the realm of electrical components. Known for its exceptional durability, efficiency, and compatibility, this product has established itself as a vital component in both residential and industrial settings. In this article, we will explore the specifics of the Schneider C11E6TM080B, examining its features, benefits, and market position.

What is the Schneider C11E6TM080B?

it is a high-performance electrical component crafted to meet the stringent demands of modern electrical systems. Renowned for its robust construction and reliable performance, this product is designed to handle a broad spectrum of electrical applications, making it an adaptable choice for various environments.

Key Specifications

  • Voltage Rating: 80V
  • Current Rating: 6A
  • Material: High-grade thermoplastic
  • Dimensions: 100mm x 50mm x 25mm
  • Weight: 150g

Features of Schneider C11E6TM080B

Durability

it is built with durability in mind. Its high-grade thermoplastic construction ensures it can withstand harsh environmental conditions, making it a dependable choice for both indoor and outdoor installations.

Efficiency

Efficiency is a hallmark of the Schneider C11E6TM080B. It is engineered to minimize energy loss, ensuring that electrical systems operate smoothly and cost-effectively.

Compatibility

This product boasts high compatibility with a variety of electrical systems. Whether for residential projects or large industrial setups, the Schneider C11E6TM080B integrates seamlessly into your design.

Applications of Schneider C11E6TM080B

Residential Use

In residential settings, it is often utilized in electrical panels and circuit breakers. Its reliability guarantees the safety and efficiency of household electrical systems.

Commercial Use

For commercial buildings, it delivers robust performance in managing electrical loads, making it ideal for offices, malls, and other commercial establishments.

Industrial Use

In industrial environments, it handles heavy-duty applications with ease. Its durability and efficiency make it perfect for factories and large-scale operations.

Benefits of Using Schneider C11E6TM080B

Cost-Effectiveness

One of the significant advantages of the Schneider C11E6TM080B is its cost-effectiveness. By reducing energy loss and minimizing maintenance expenses, it provides excellent value for money.

Safety Enhancements

Safety is a critical aspect of electrical systems, and the Schneider C11E6TM080B excels in this area. Its sturdy design and high-quality materials ensure optimal safety standards.

Environmental Impact

The Schneider C11E6TM080B is designed with sustainability in mind. Its efficient performance helps lower energy consumption, contributing to a reduced carbon footprint.

Installation Process

Pre-Installation Requirements

Before installing the Schneider C11E6TM080B, ensure you have all the necessary tools and safety equipment. This includes insulated gloves, screwdrivers, and a voltage tester.

Step-by-Step Installation Guide

  1. Turn Off Power: Ensure the main power supply is turned off to avoid any electrical hazards.
  2. Mounting: Securely mount the Schneider C11E6TM080B in the designated space.
  3. Wiring: Connect the wires to the appropriate terminals, ensuring a tight fit.
  4. Testing: After installation, test the system to ensure everything is working correctly.
  5. Final Check: Perform a final inspection to verify that all connections are secure and the component is properly installed.

Maintenance and Troubleshooting

Regular Maintenance Tips

  • Routine Inspections: Regularly check for any signs of wear and tear.
  • Cleaning: Keep the component clean and free from dust and debris.
  • Tightening Connections: Ensure all connections remain tight to prevent any electrical faults.

Common Issues and Solutions

  • Overheating: If the component overheats, check for loose connections or overloaded circuits.
  • Inconsistent Performance: Ensure all wires are properly connected and there are no signs of corrosion.
SKU: C11E6TM080B Category:
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 160E
product or component type Circuit breaker
Device application Distribution
poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 80 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
16 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Performance level E 16 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 25 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
16 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
8 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 6.96 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals Compression lug/busbar
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 12 module
Trip unit rating 80 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1000 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 108 mm
Height (H) 137 mm
Depth (D) 80 mm
net weight 1.42 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.000 cm
Package 1 Width 13.000 cm
Package 1 Length 22.000 cm
Package 1 Weight 1.572 kg
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 10.190 kg
Unit Type of Package 3 P12
Number of Units in Package 3 144
Package 3 Height 150.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 254.490 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11E6TM080B | Circuit breaker, ComPacT NSXm 160E, 16kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 80A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024