Schneider C11F3TM100L: A Comprehensive Guide

Introduction

The Schneider C11F3TM100L is a crucial component in modern electrical systems, renowned for its exceptional reliability and performance. This guide explores the features, applications, and benefits of this product, demonstrating why it is a top choice for various sectors.

Background on Schneider Electric

History of Schneider Electric

Schneider Electric has a long-standing history as a leader in energy management and automation. Established in the 19th century, the company has grown from a small iron and steel firm to a global innovator in electrical engineering.

Key Contributions to Electrical Engineering

Over the decades, Schneider Electric has introduced groundbreaking technologies that have transformed energy management and automation. Their products are synonymous with innovation, efficiency, and reliability.

Product Overview

Detailed Description of Schneider C11F3TM100L

The Schneider C11F3TM100L is an advanced electrical component designed to cater to a wide range of applications. Its robust design and high performance make it suitable for demanding environments.

Technical Specifications

  • Voltage Rating: 440V
  • Current Rating: 100A
  • Frequency: 50/60Hz
  • Dimensions: 150mm x 140mm x 100mm
  • Weight: 1.5kg

Key Features

Durability and Build Quality

One of the standout features of it is its durability. Constructed from high-quality materials, it is built to last and perform reliably even under strenuous conditions.

Performance and Efficiency

it is designed for optimal performance, delivering high efficiency and reliability. Its advanced design reduces energy loss, ensuring maximum output and cost savings.

Installation and Setup

Step-by-Step Installation Guide

  1. Preparation: Gather all necessary tools and equipment.
  2. Mounting: Securely mount the Schneider C11F3TM100L in the designated location.
  3. Wiring: Connect the wires as per the installation manual.
  4. Testing: Conduct tests to ensure proper installation and functionality.

Necessary Tools and Equipment

  • Screwdrivers
  • Wire strippers
  • Multimeter
  • Installation manual

Applications

Industrial Uses

In industrial settings, the Schneider C11F3TM100L is widely used in machinery and automation systems due to its robustness and reliability.

Commercial Uses

Commercial buildings benefit from the Schneider C11F3TM100L’s efficiency and safety features, making it a popular choice for offices, shopping centers, and other commercial facilities.

Residential Uses

In residential areas, this product is ideal for home automation systems, ensuring safe and efficient power distribution.

Advantages over Competitors

Unique Selling Points

it offers several unique advantages, including superior build quality, enhanced safety features, and excellent customer support.

Comparative Analysis

Compared to similar products, it consistently ranks higher in terms of performance, durability, and user satisfaction.

Safety Features

Built-in Safety Mechanisms

it includes multiple safety features such as overload protection, short-circuit protection, and thermal monitoring to prevent accidents and equipment damage.

Compliance with International Standards

This product adheres to various international safety standards, ensuring it meets rigorous safety and performance criteria.

Maintenance and Troubleshooting

Routine Maintenance Tips

Regular maintenance is essential for optimal performance. Inspect the unit periodically, clean any dust or debris, and check for signs of wear and tear.

Common Issues and Solutions

  • Overheating: Ensure proper ventilation and check for obstructions.
  • Power Fluctuations: Verify all connections and replace any faulty components.
  • Unusual Noises: Inspect for loose parts and secure them if necessary.
SKU: C11F3TM100L Category: Brand:
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 160F
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 8.77 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
1 Everlink lug wire size 2.5…70 mm², flexible copper
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 9 module
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1250 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 81 mm
Height (H) 137 mm
Depth (D) 80 mm
net weight 1.06 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.0 cm
Package 1 Width 9.0 cm
Package 1 Length 21.0 cm
Package 1 Weight 1.204 kg
Unit Type of Package 2 S03
Number of Units in Package 2 9
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 11.238 kg
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 160F
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Power dissipation per pole 8.77 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper
Connection pitch 35 mm with spreaders 27 mm without spreaders
9 mm pitches 9 module
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1250 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 81 mm
Height (H) 137 mm
Depth (D) 80 mm
net weight 1.06 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating 5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.0 cm
Package 1 Width 9.0 cm
Package 1 Length 21.0 cm
Package 1 Weight 1.204 kg
Unit Type of Package 2 S03
Number of Units in Package 2 9
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 11.238 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11F3TM100L | circuit breaker ComPacT NSXm F (36 kA at 415 VAC). 3P 3d. 100 A rating TMD trip unit”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024