Let's Chat
-36%

Schneider C11F44V100L | Circuit breaker ComPacT NSXm F (36kA at 415VAC), 4 Poles 4d, 100A rating Micrologic 4.1 trip unit

Schneider Electric
Availability:

Out of stock


Schneider C11F44V100L | Circuit breaker ComPacT NSXm F (36kA at 415VAC), 4 Poles 4d, 100A rating Micrologic 4.1 trip unit

40,836 EGP 63,806 EGP

Out of stock

Compare

Schneider C11F44V100L: A Comprehensive Guide

Introduction

it is a crucial component in the world of modern electrical systems, renowned for its reliability and efficiency. This guide explores the features and applications of this exceptional product, highlighting why it is a preferred choice for various sectors.

Background on Schneider Electric

History of Schneider Electric

Schneider Electric, a leading name in energy management and automation, has a rich history dating back to the 19th century. Originally a small iron and steel company, it has transformed into a global leader known for its innovative solutions and commitment to sustainability.

Key Contributions to Electrical Engineering

Schneider Electric has consistently contributed to advancements in electrical engineering, introducing cutting-edge technologies that have revolutionized energy management and automation. Their products are synonymous with quality, efficiency, and innovation.

Product Overview

Detailed Description of Schneider C11F44V100L

it is an advanced electrical component designed for diverse applications. Its robust construction and high-performance capabilities make it an ideal choice for demanding environments.

Technical Specifications

  • Voltage Rating: 440V
  • Current Rating: 100A
  • Frequency: 50/60Hz
  • Dimensions: 120mm x 110mm x 80mm
  • Weight: 1.2kg

Key Features

Durability and Build Quality

A standout feature of it is its durability. Constructed from high-quality materials, it ensures long-lasting performance even under strenuous conditions.

Performance and Efficiency

it is engineered for optimal performance, delivering high efficiency and reliability. Its advanced design minimizes energy loss, ensuring maximum output and cost savings.

Installation and Setup

Step-by-Step Installation Guide

  1. Preparation: Gather all required tools and equipment.
  2. Mounting: Secure the Schneider C11F44V100L in the designated location.
  3. Wiring: Connect the wires as per the installation manual.
  4. Testing: Conduct tests to ensure proper installation and functionality.

Necessary Tools and Equipment

  • Screwdrivers
  • Wire strippers
  • Multimeter
  • Installation manual

Applications

Industrial Uses

In industrial settings, the Schneider C11F44V100L is widely used in machinery and automation systems due to its robustness and reliability.

Commercial Uses

Commercial buildings benefit from the Schneider C11F44V100L’s efficiency and safety features, making it a popular choice for offices, shopping centers, and other commercial facilities.

Residential Uses

In residential areas, this product is ideal for home automation systems, ensuring safe and efficient power distribution.

Advantages over Competitors

Unique Selling Points

The Schneider C11F44V100L offers several unique advantages, including superior build quality, enhanced safety features, and excellent customer support.

Comparative Analysis

Compared to similar products, the Schneider C11F44V100L consistently ranks higher in terms of performance, durability, and user satisfaction.

Safety Features

Built-in Safety Mechanisms

The Schneider C11F44V100L includes multiple safety features such as overload protection, short-circuit protection, and thermal monitoring to prevent accidents and equipment damage.

Compliance with International Standards

This product adheres to various international safety standards, ensuring it meets rigorous safety and performance criteria.

Maintenance and Troubleshooting

Routine Maintenance Tips

Regular maintenance is essential for optimal performance. Inspect the unit periodically, clean any dust or debris, and check for signs of wear and tear.

Common Issues and Solutions

  • Overheating: Ensure proper ventilation and check for obstructions.
  • Power Fluctuations: Verify all connections and replace any faulty components.
  • Unusual Noises: Inspect for loose parts and secure them if necessary.
SKU: C11F44V100L Category:
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 160F
product or component type Earth leakage circuit breaker
Device application Distribution
poles description 4P
Protected poles description 4D
Neutral position Left
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name MicroLogic 4.1
Trip unit technology Electronic
Trip unit protection functions LSoIR
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 85 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 4.77 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…70 mm², fine stranded copper
1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 12 module
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40…100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 200 s at 1.5 x Ir
8 s at 6 x Ir
5 s at 7.2 x Ir
Neutral protection settings 1 x Ir (4D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5…10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
Earth-leakage protection Integrated
Earth-leakage protection class Class A
Class AC
Earth-leakage protection sensitity adjustment type IΔn Adjustable
[IΔn] earth-leakage protection sensitivity adjustment range 30 mA
100 mA
300 mA
500 mA
1 A
3 A
5 A
Earth-leakage sensitivity 30 mA for class A
100 mA for class A
300 mA for class A
500 mA for class A
1 A for class A
30 mA for class AC
100 mA for class AC
300 mA for class AC
500 mA for class AC
1 A for class AC
3 A for class AC
5 A for class AC
Earth-leakage protection time delay adjustement type Δt Adjustable
[Δt] Earth-leakage protection time delay adjustment range 0 ms
60 ms
150 ms
500 ms
1000 ms
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 108 mm
Height (H) 144 mm
Depth (D) 80 mm
net weight 1.63 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.0 cm
Package 1 Width 13.0 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.816 kg
Unit Type of Package 2 S03
Number of Units in Package 2 4
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.642 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11F44V100L | Circuit breaker ComPacT NSXm F (36kA at 415VAC), 4 Poles 4d, 100A rating Micrologic 4.1 trip unit”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024