Schneider C11H3TM032L: A Comprehensive Guide

Introduction

In the ever-evolving world of industrial technology, the Schneider C11H3TM032L stands out as a reliable and efficient component. This guide will provide an in-depth look at this product, highlighting its features, applications, and benefits, ensuring you have all the information needed to make an informed decision.

What is the Schneider C11H3TM032L?

it is a high-performance industrial component designed to meet the rigorous demands of various industrial applications. Manufactured by Schneider Electric, a leader in energy management and automation, this product promises durability and efficiency.

Key Features

  • High Efficiency: Optimized to deliver maximum performance with minimal energy consumption.
  • Robust Design: Built to endure harsh industrial environments.
  • Compact Size: Easily fits into existing systems without extensive modifications.

Technical Specifications

To fully appreciate the capabilities of it, it’s essential to understand its technical specifications.

Dimensions and Weight

  • Height: 90 mm
  • Width: 45 mm
  • Depth: 65 mm
  • Weight: 250 grams

Power Ratings

  • Voltage: 24V DC
  • Current: 8A
  • Power Output: 192W

Operating Conditions

  • Temperature Range: -20°C to 55°C
  • Humidity: 5% to 95% non-condensing

Applications of the Schneider C11H3TM032L

This versatile product is employed in a variety of industries, ensuring reliable performance across multiple applications.

Industries Using This Product

  • Manufacturing: Enhances operational efficiency on production lines.
  • Energy: Crucial in the functioning of renewable energy systems.
  • Automation: Integral to automated control systems in various industrial settings.

Common Use Cases

  • Motor Control: Provides precise motor function control.
  • Power Distribution: Ensures consistent power distribution across systems.
  • Signal Transmission: Maintains signal integrity in control systems.

Advantages of Using the Schneider C11H3TM032L

Opting for it comes with numerous advantages, making it a top choice for many industrial applications.

Efficiency

Designed with efficiency in mind, this product helps reduce energy consumption, leading to lower operational costs.

Durability

Engineered to last, it can withstand the most challenging industrial environments, ensuring longevity and reliability.

Cost-Effectiveness

While the initial investment might be significant, the long-term savings in maintenance and energy costs make it a cost-effective choice.

Installation Process

Proper installation is crucial for the optimal performance of the Schneider C11H3TM032L.

Pre-Installation Checklist

  • Verify Compatibility: Ensure the product is compatible with your system.
  • Check Power Supply: Confirm that the power supply meets the product’s requirements.
  • Review the Manual: Familiarize yourself with the installation instructions provided by Schneider Electric.

Step-by-Step Installation Guide

  1. Turn Off Power: Ensure the power supply is turned off before beginning the installation.
  2. Mount the Product: Securely mount the Schneider C11H3TM032L in the designated location.
  3. Connect Wiring: Follow the wiring diagram to connect the product to your system.
  4. Test the Installation: Turn on the power and test the product to ensure it is functioning correctly.

Maintenance and Troubleshooting

Regular maintenance is key to ensuring the longevity and optimal performance of the Schneider C11H3TM032L.

Regular Maintenance Tips

  • Inspect Regularly: Check for any signs of wear or damage.
  • Clean Periodically: Keep the product free from dust and debris.
  • Check Connections: Ensure all connections are secure and free from corrosion.

Common Issues and Solutions

  • Power Fluctuations: Check the stability of the power supply.
  • Overheating: Ensure proper ventilation around the product.
  • Signal Loss: Verify the integrity of wiring connections.
SKU: C11H3TM032L Category: Brand:
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 63H
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 32 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level H 70 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 100 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 2.94 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
1 Everlink lug wire size 2.5…70 mm², flexible copper
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 9 module
Trip unit rating 32 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 600 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 81 mm
Height (H) 137 mm
Depth (D) 80 mm
net weight 1.06 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.000 cm
Package 1 Width 13.000 cm
Package 1 Length 22.000 cm
Package 1 Weight 1.300 kg
Unit Type of Package 2 S03
Number of Units in Package 2 9
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 12.290 kg
Unit Type of Package 3 P12
Number of Units in Package 3 216
Package 3 Height 150.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 304.890 kg
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 63H
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 32 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level H 70 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Power dissipation per pole 2.94 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper
Connection pitch 35 mm with spreaders 27 mm without spreaders
9 mm pitches 9 module
Trip unit rating 32 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 600 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 81 mm
Height (H) 137 mm
Depth (D) 80 mm
net weight 1.06 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating 5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.000 cm
Package 1 Width 13.000 cm
Package 1 Length 22.000 cm
Package 1 Weight 1.300 kg
Unit Type of Package 2 S03
Number of Units in Package 2 9
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 12.290 kg
Unit Type of Package 3 P12
Number of Units in Package 3 216
Package 3 Height 150.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 304.890 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11H3TM032L | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 3 poles, TMD trip unit 32A”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024