Let's Chat
-36%

Schneider C11H3TM050L | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 3 poles, TMD trip unit 50A, EverLink lugs

Availability:

Out of stock


Schneider C11H3TM050L | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 3 poles, TMD trip unit 50A, EverLink lugs

13,257 EGP 20,714 EGP

Out of stock

Compare

Schneider C11H3TM050L: A Comprehensive Guide

Introduction

In today’s industrial landscape, efficiency and reliability are paramount. One product that stands out in this realm is it. This guide will dive deep into the intricacies of this essential component, exploring its features, applications, and benefits.

What is the Schneider C11H3TM050L?

it is a high-performance industrial product known for its robust design and efficiency. Engineered by Schneider Electric, this product is designed to meet the demanding needs of various industrial applications.

Key Features

  • High Efficiency: Maximizes performance while minimizing energy consumption.
  • Durability: Built to withstand harsh industrial environments.
  • Compact Design: Fits easily into various systems without requiring extensive modifications.

Technical Specifications

Understanding the technical specifications of it is crucial for proper application and installation.

Dimensions and Weight

  • Height: 100 mm
  • Width: 50 mm
  • Depth: 70 mm
  • Weight: 300 grams

Power Ratings

  • Voltage: 24V DC
  • Current: 10A
  • Power Output: 240W

Operating Conditions

  • Temperature Range: -20°C to 60°C
  • Humidity: 5% to 95% non-condensing

Applications of the Schneider C11H3TM050L

This versatile product finds its use in a variety of industries, from manufacturing to energy production.

Industries Using This Product

  • Manufacturing: Enhances the efficiency of production lines.
  • Energy: Integral in the operation of renewable energy systems.
  • Automation: Key component in automated industrial systems.

Common Use Cases

  • Motor Control: Ensures precise control of motor functions.
  • Power Distribution: Reliable distribution of power across systems.
  • Signal Transmission: Maintains integrity of signal transmission in control systems.

Advantages of Using the Schneider C11H3TM050L

Choosing it brings several benefits to the table, making it a preferred choice for many industrial applications.

Efficiency

The product’s design focuses on maximizing energy efficiency, reducing operational costs.

Durability

Built to last, the Schneider C11H3TM050L can handle the toughest industrial environments, ensuring long-term reliability.

Cost-Effectiveness

While initial investment might be high, the long-term savings on maintenance and energy make it a cost-effective solution.

Installation Process

Installing the Schneider C11H3TM050L is straightforward, but it’s essential to follow proper procedures to ensure optimal performance.

Pre-Installation Checklist

  • Ensure Compatibility: Verify that the product is compatible with your system.
  • Check Power Supply: Ensure the power supply meets the product’s requirements.
  • Read the Manual: Familiarize yourself with the installation guide provided by Schneider Electric.

Step-by-Step Installation Guide

  1. Turn Off Power: Ensure the power supply is turned off before beginning installation.
  2. Mount the Product: Securely mount the Schneider C11H3TM050L in the designated location.
  3. Connect Wiring: Follow the wiring diagram to connect the product to your system.
  4. Test the Installation: Turn on the power and test the product to ensure it is functioning correctly.

Maintenance and Troubleshooting

Regular maintenance is key to the longevity and performance of the Schneider C11H3TM050L.

Regular Maintenance Tips

  • Inspect Regularly: Check for any signs of wear or damage.
  • Clean Periodically: Keep the product free from dust and debris.
  • Check Connections: Ensure all connections are secure and free from corrosion.

Common Issues and Solutions

  • Power Fluctuations: Check power supply stability.
  • Overheating: Ensure proper ventilation around the product.
  • Signal Loss: Verify wiring connections and integrity
SKU: C11H3TM050L Category:
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 63H
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 50 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level H 70 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 100 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 4.81 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
1 Everlink lug wire size 2.5…70 mm², flexible copper
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 9 module
Trip unit rating 50 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 600 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 81 mm
Height (H) 137 mm
Depth (D) 80 mm
net weight 1.06 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.0 cm
Package 1 Width 9.0 cm
Package 1 Length 21.0 cm
Package 1 Weight 1.207 kg
Unit Type of Package 2 S03
Number of Units in Package 2 9
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 11.241 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11H3TM050L | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 3 poles, TMD trip unit 50A, EverLink lugs”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024