Let's Chat
-36%

Schneider C11H44V025L | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 4 poles, MicroLogic 4.1 trip unit 25A, EverLink lugs

Availability:

Out of stock


Schneider C11H44V025L | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 4 poles, MicroLogic 4.1 trip unit 25A, EverLink lugs

49,394 EGP 77,178 EGP

Out of stock

Compare

Schneider C11H44V025L: A Comprehensive Guide

Introduction

The Schneider C11H44V025L is a highly efficient and reliable circuit breaker designed to protect electrical circuits from overloads and short circuits. This article will provide an in-depth look at the features, technical specifications, applications, installation process, and benefits of the Schneider C11H44V025L, offering a thorough understanding of its capabilities and advantages.

What is the Schneider C11H44V025L?

The Schneider C11H44V025L is a versatile and robust circuit breaker from Schneider Electric’s C11 series. Engineered to safeguard electrical systems, it ensures the safety and reliability of circuits in various applications, ranging from residential to industrial settings.

General Description

This circuit breaker combines thermal protection for overload conditions and magnetic protection for short-circuit conditions. Its design and construction make it a dependable solution for a wide range of electrical protection needs.

Key Specifications

  • Voltage Rating: Up to 690V AC
  • Current Rating: 25A
  • Breaking Capacity: 25 kA
  • Number of Poles: 4
  • Trip Class: 10A

Intended Applications

The C11H44V025L is used in various settings, including residential, commercial, and industrial environments, to protect electrical circuits for motors, lighting systems, and other equipment.

Features of Schneider C11H44V025L

The Schneider C11H44V025L offers several features that make it a reliable and efficient choice for circuit protection.

High Performance

The circuit breaker is designed to handle significant electrical loads, providing robust protection against overloads and short circuits.

Compact Design

Its compact design allows for easy installation in electrical panels and distribution boards, making it suitable for use in tight spaces.

Safety Features

The C11H44V025L includes thermal-magnetic protection to prevent overheating and short circuits. It also has a manual reset button for added convenience.

Technical Specifications

To fully understand the capabilities of the Schneider C11H44V025L, let’s delve into its technical specifications.

Voltage Ratings

The C11H44V025L can operate effectively at voltages up to 690V AC, making it suitable for a wide range of electrical systems.

Current Capacity

With a current rating of 25A, this circuit breaker can manage substantial electrical loads, ensuring reliable performance in various applications.

Breaking Capacity

The circuit breaker has a breaking capacity of 25 kA, which means it can interrupt short-circuit currents up to 25,000 amps without sustaining damage.

Trip Class

The trip class of 10A indicates that the breaker will trip within a specific time frame under overload conditions, providing reliable protection for your electrical circuits.

Installation and Setup

Proper installation is crucial for the Schneider C11H44V025L to function effectively. Here’s a step-by-step guide to help you with the process.

Pre-installation Requirements

Before starting the installation, ensure you have the following:

  • Necessary tools and safety gear
  • A clear and accessible installation site
  • The correct wiring diagram for your setup

Step-by-step Installation Guide

  1. Turn off Power: Make sure the power supply is completely turned off to avoid electrical hazards.
  2. Mount the Breaker: Install the C11H44V025L into the designated slot in your electrical panel or distribution board.
  3. Connect Wires: Connect the incoming and outgoing wires to the breaker terminals, following the wiring diagram.
  4. Check Connections: Ensure all connections are secure and properly aligned.
  5. Restore Power: Turn the power back on and test the breaker to verify that it is functioning correctly.

Safety Precautions During Installation

Always follow electrical safety practices:

  • Wear appropriate protective gear.
  • Ensure the installation area is dry and free of any hazards.
  • Double-check all connections before restoring power.
SKU: C11H44V025L Category:
Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 63H
product or component type Earth leakage circuit breaker
Device application Distribution
poles description 4P
Protected poles description 4D
Neutral position Left
[In] rated current 25 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level H 70 kA 415 V AC
Trip unit name MicroLogic 4.1
Trip unit technology Electronic
Trip unit protection functions LSoIR
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 100 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
Power dissipation per pole 1.01 W
mounting support Backplate
Mounting position Horizontal and vertical
Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…70 mm², fine stranded copper
1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 12 module
Trip unit rating 25 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 10…25 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 200 s at 1.5 x Ir
8 s at 6 x Ir
5 s at 7.2 x Ir
Neutral protection settings 1 x Ir (4D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5…10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 375 A
Earth-leakage protection Integrated
Earth-leakage protection class Class A
Class AC
Earth-leakage protection sensitity adjustment type IΔn Adjustable
[IΔn] earth-leakage protection sensitivity adjustment range 30 mA
100 mA
300 mA
500 mA
1 A
3 A
5 A
Earth-leakage sensitivity 30 mA for class A
100 mA for class A
300 mA for class A
500 mA for class A
1 A for class A
30 mA for class AC
100 mA for class AC
300 mA for class AC
500 mA for class AC
1 A for class AC
3 A for class AC
5 A for class AC
Earth-leakage protection time delay adjustement type Δt Adjustable
[Δt] Earth-leakage protection time delay adjustment range 0 ms
60 ms
150 ms
500 ms
1000 ms
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 108 mm
Height (H) 144 mm
Depth (D) 80 mm
net weight 1.63 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating
5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.0 cm
Package 1 Width 14.0 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.858 kg
Unit Type of Package 2 S03
Number of Units in Package 2 4
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.873 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider C11H44V025L | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 4 poles, MicroLogic 4.1 trip unit 25A, EverLink lugs”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024